IEC Magnetic Contactor, 3 Poles, 24 V DC, 9 A, Reversing: No, SCHNEIDER, Mfr# LC1D09BD

$103,99

Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V DC, Number of Poles 3, Full Load Current - Inductive 9 A, Full Load Current - Resistive 20 A, Reversing Capability Non-Reversing, Overall Height 3.03 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$111.54
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER
Mfr #: LC1D09BD
Availability: Ships in 1 days
SKU: GRG3000645 Category:
ItemIEC Magnetic Contactor
Full Load Amps-Inductive9 A
Full Load Amps-Resistive20 A
ActionNon-Reversing
Number of Poles3
Coil Volts24 V DC
ReversingNo
HP @ 1 Phase - 120V1/2 hp
HP @ 1 Phase - 230V1
HP @ 1 Phase - 240V1 hp
Height3.03 in
Width1.77 in
HP @ 3 Phase - 208V2 hp
HP @ 3 Phase - 240V2 hp
HP @ 3 Phase - 575V7 1/2 hp
Depth3.38 in
HP @ 3 Phase - 480V5 hp
Enclosure NEMA RatingNo Enclosure
Hz50/60
Auxiliary Contact Form1NO/1NC
Frame / Series / Class / CodeTeSys
Aux. Contact Configuration1NO/1NC
StandardsBV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
SeriesTeSys Deca
NEMA SizeNot Applicable
FeaturesBuilt-In Bi-Directional Peak Limiting Diode Suppressor
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Rated Voltage690V AC, 300V DC
Overvoltage CategoryCAT III
Fuse Amps10 A (Signalling Circuit), 25 A (Type 1 Power Circuit), 20 A (Type 2 Power Circuit)
IP RatingIP20
Operating Time53.55 to 72.45 ms (Closing), 16 to 24 ms (Opening)
Max. Operating Watts2.2 kW (at 220 to 230V AC 50/60 Hz AC-3), 4 kW (at 380 to 400V AC 50/60 Hz AC-3), 4 kW 415 to (at 440V AC 50/60 Hz AC-3), 5.5 kW (at 500V AC 50/60 Hz AC-3), 5.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3e), 4 kW (at 380 to 400V AC 50/60 Hz AC-3e), 4 kW 415 to (at 440V AC 50/60 Hz AC-3e), 5.5 kW (at 500V AC 50/60 Hz AC-3e), 5.5 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Rated Breaking Capacity250 A @ 440V
Thermal Amperage25 A (at 60°C Power Circuit), 10 A (at 60°C Signalling Circuit)
Switching Voltage17 V (Signalling Circuit)
Switching Current5 mA (Signalling Circuit)
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Non-Overlap Time1.5 ms
Electrical Durability0.6 Mcycles (25 A, AC-1, Less than 440 V), 2 Mcycles (9 A, AC-3, Less than 440 V), 2 Mcycles (9 A, AC-3e, Less than 440 V)
Includes Protective CoverYes
Mounts OnPlate, Rail
Max. Temperature850°C
Shock Resistance15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
ApplicationMotor Control, Resistive Load
Rated Short-Time Withstand Current105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Rated Insulation Volts600/690V
Electrical ConnectionScrew Clamp Terminals
Impulse Withstand Voltage6 kV
Fire RatingUL 94 V1
Mechanical Durability30 Mcycles
Rated Making Capacity250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Environmental AttributesMercury Free, PVC Free, Pollution Degree 3
Control Circuit Voltage LimitsDrop-Out DC: 0.1 to 0.25 Uc (at -40 to 70°C), Operational DC: 0.7 to 1.25 Uc (at -40 to 60°C), 1 to 1.25 Uc (at 60 to 70°C)
Working HeightUp to 9842.52 ft
Impedance2.5 mOhm
Signalling Circuit Frequency25 to 400 Hz
Operating Speed3600 cycles per hr
Tightening Torque1.7 Nm
Net Weight0.48 kg
Full Load Current - Resistive20 A
Number of Auxillary Contacts2
Horsepower @ Three Phase - 600V AC7 1/2 hp
Full Load Current - Inductive9 A
Horsepower @ Three Phase - 240V AC2 hp
Mounting StyleDIN Rail, Plate
Maximum Operating Temperature140 Degrees F
Horsepower @ Three Phase - 208V AC2 hp
Number of Normally Open Main Contacts3
Overall Depth3.74 in
Contactor StyleIEC
Includes Auxiliary ContactsYes
Frequency50/60 Hz
NEMA Enclosure RatingNo Enclosure
Overall Width1.77 in
Horsepower @ Three Phase - 480V AC5 hp
Horsepower @ Single Phase - 120V AC1/3 hp
Reversing CapabilityNon-Reversing
Coil Voltage24V DC
PhaseThree
Embedded Surge SuppressorYes
Electrical Operating Durability2,000,000, 600,000
Terminal Connection TypeScrew Clamp Terminals
Mechanical Operating Durability30,000,000
Minimum Operating Temperature-40 Degrees F
NEMA Enclosure MaterialNot Applicable
Horsepower @ Single Phase - 240V AC1 hp
Maximum Voltage Rating690V AC
Overall Height3.03 in
Resistance PropertiesFire Resistant, Insulation Resistant
Poles Description3P
Auxiliary Contact Composition1 NO + 1 NC
Rated Impulse Withstand Voltage6 kV IEC 60947
Rated Operational Current9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Protective CoverWith
Coil TechnologyBuilt-in bidirectional peak limiting diode suppressor
Maximum Horse Power Rating1 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 2 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 2 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 5 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 575/600 V AC 50/60 Hz for 3 phase motors, 0.33 hp at 115 V AC 50/60 Hz for 1 phase motors
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Pole Contact Composition3 NO
Product Or Component TypeContactor
Inrush Power in W5.4 W 68°F (20°C))
Fire Resistance1562°F (850°C) IEC 60695-2-1
Flame RetardanceV1 conforming to UL 94
Conventional Free Air Thermal Current25 A (at 140°F (60°C)) for power circuit, 10 A (at 140°F (60°C)) for signalling circuit
Permissible Ambient Air Temperature Around The Device-40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Motor Power KW2.2 kW at 220 to 230 V AC 50/60 Hz (AC-3), 4 kW at 380 to 400 V AC 50/60 Hz (AC-3), 4 kW at 415 to 440 V AC 50/60 Hz (AC-3), 5.5 kW at 500 V AC 50/60 Hz (AC-3), 5.5 kW at 660 to 690 V AC 50/60 Hz (AC-3), 2.2 kW at 400 V AC 50/60 Hz (AC-4), 2.2 kW at 220 to 230 V AC 50/60 Hz (AC-3e), 4 kW at 380 to 400 V AC 50/60 Hz (AC-3e), 4 kW at 415 to 440 V AC 50/60 Hz (AC-3e), 5.5 kW at 500 V AC 50/60 Hz (AC-3e), 5.5 kW at 660 to 690 V AC 50/60 Hz (AC-3e)
Rated Insulation VoltagePower circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL
Protective TreatmentTHIEC 60068-2-30
Time Constant28 ms
Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
IP Degree Of ProtectionIP20 front face IEC 60529
Minimum Switching Current5 mA for signalling circuit
Minimum Switching Voltage17 V for signalling circuit
Pollution Degree3
Control Circuit TypeDC standard
Power Dissipation Per Pole1.56 W AC-1, 0.2 W AC-3, 0.2 W AC-3e
Rated Operational VoltagePower circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC
Average Impedance2.5 mOhm - Ith 25 A 50 Hz for power circuit
Rated Short Time Withstand Current105 A 104°F (40°C) - 10 s for power circuit, 210 A 104°F (40°C) - 1 s for power circuit, 30 A 104°F (40°C) - 10 min for power circuit, 61 A 104°F (40°C) - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Utilisation CategoryAC-4, AC-1, AC-3, AC-3e
Contactor ApplicationMotor control, Resistive load
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1, 25 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 20 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
IRMS Rated Making Capacity250 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
Connections - TerminalsPower circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end
Mounting SupportPlate, Rail
Contact CompatibilityM4
Compatibility CodeLC1D
Mechanical RobustnessVibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor open 10 Gn for 11 ms), Shocks contactor closed 15 Gn for 11 ms)
Operating Altitude0 to 9842.52 ft (0 to 3000 m)
Product CertificationsLROS (Lloyds register of shipping), CSA, UL, GOST, DNV, CCC, GL, BV, RINA, UKCA
Maximum Operating Rate3600 cyc/h 140°F (60°C)
Hold-In Power Consumption in W5.4 W 68°F (20°C)
Country of Origin (subject to change)Indonesia
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#24 V DC
#9 A
#Reversing: No
#SCHNEIDER
#Mfr LC1D09BD
#SCHNEIDER
#GRG3000645
#mfr:LC1D09BD
#part number:LC1D09BD
#pn:LC1D09BD
#part code:LC1D09BD
#item number:LC1D09BD
#product code:LC1D09BD
#manufacturer number:LC1D09BD
#manufacturers part number:LC1D09BD
#mfn:LC1D09BD

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!