IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 480V AC, Number of Poles 3, Full Load Current - Inductive 150 A, Full Load Current - Resistive 200 A, Reversing Capability Non-Reversing, Overall Height 6.22 in, Overall Width 0.47 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

Out of stock

Brand Name: SCHNEIDER
Mfr #: LC1D150T7
Availability: Ships in 1 days
SKU: GRG2432473 Category:
Full Load Amps-Inductive150 A
ItemIEC Magnetic Contactor
ActionNon-Reversing
Full Load Amps-Resistive200 A
Number of Poles3
Coil Volts480 V AC
ReversingNo
Height4.33 in
Width4.33 in
HP @ 3 Phase - 208V40 hp
HP @ 3 Phase - 575V125 hp
Depth5.12 in
HP @ 3 Phase - 240V50 hp
Enclosure NEMA RatingNo Enclosure
HP @ 3 Phase - 480V100 hp
Aux. Contact Configuration1NO/1NC
Hz50/60
Auxiliary Contact Form1NO/1NC
StandardsBV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
NEMA SizeNot Applicable
SeriesTeSys Deca
Fire RatingUL 94 V1
Electrical Durability0.85 Mcycles (150 A, AC-3, Less than 440 V), 1 Mcycles (200 A, AC-1, Less than 440 V), 0.85 Mcycles (150 A, AC-3e, Less than 440 V)
Inrush VA280 to 350 VA
Net Weight2.5 kg
Rated Short-Time Withstand Current250 A (at 40°C for 10 min Power Circuit), 580 A (at 40°C for 1 min Power Circuit), 1200 A (at 40°C for 10 s Power Circuit), 1400 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Operating Time20 to 35 ms (Closing), 40 to 75 ms (Opening)
Switching Voltage17 V (Signalling Circuit)
Working HeightUp to 9842.52 ft
Watts Loss3 to 4.5W
IP RatingIP20
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1660 A @ 440V (Power Circuit)
Max. Temperature850°C
Impulse Withstand Voltage8 kV
Rated Breaking Capacity1400 A @ 440V
Thermal Amperage200 A (at 60°C Power Circuit)
Mechanical Durability8 Mcycles
Signalling Circuit Frequency25 to 400 Hz
Switching Current5 mA (Signalling Circuit)
ApplicationMotor Control, Resistive Load
Shock Resistance15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open)
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Rated Insulation Volts600/1000V (Power Circuit), 600/690V (Signalling Circuit)
Mounts OnPlate, Rail
Overvoltage CategoryCAT III
Impedance0.6 mOhm
Hold VA2 to 18 VA
Rated Voltage1000V AC, 300V DC
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Electrical ConnectionScrew Clamp Terminals
Control Circuit Voltage LimitsDrop-Out AC: 0.3 to 0.5 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.15 Uc (at -40-55°C 50/60 Hz), 1 to 1.15 Uc (at 55-70°C 50/60 Hz)
FeaturesBuilt-In Bi-Directional Peak Limiting Diode Suppressor
Fuse Amps10 A (Signalling Circuit), 315 A (Type 1 Power Circuit), 250 A (Type 2 Power Circuit)
Max. Operating Watts40 kW (at 220 to 230V AC 50/60 Hz AC-3), 75 kW (at 380 to 400V AC 50/60 Hz AC-3), 80 kW 415 to (at 440V AC 50/60 Hz AC-3), 90 kW (at 500V AC 50/60 Hz AC-3), 100 kW (at 660 to 690V AC 50/60 Hz AC-3), 75 kW (at 1000V AC 50/60 Hz AC-3), 22 kW (at 400V AC 50/60 Hz AC-4), 40 kW (at 220 to 230V AC 50/60 Hz AC-3e), 75 kW (at 380 to 400V AC 50/60 Hz AC-3e), 80 kW (at 415 to 440V AC 50/60 Hz AC-3e), 90 kW (at 500V AC 50/60 Hz AC-3e), 100 kW (at 660 to 690V AC 50/60 Hz AC-3e), 75 kW (at 1000V AC 50/60 Hz AC-3e)
Tightening Torque1.2 Nm (Control Circuit), 12 Nm (Power Circuit)
Includes Protective CoverYes
Environmental AttributesMercury Free, PVC Free, Pollution Degree 3
Non-Overlap Time1.5 ms
Operating Speed1200 cycles per hr
Maximum Voltage Rating1000V AC
Contactor StyleIEC
Overall Width0.47 in
Frequency50/60 Hz
Horsepower @ Three Phase - 480V AC100 hp
Horsepower @ Three Phase - 208V AC40 hp
Coil Voltage480V AC
Terminal Connection TypeScrew Clamp Terminals
Horsepower @ Three Phase - 240V AC50 hp
Overall Height6.22 in
Full Load Current - Resistive200 A
NEMA Enclosure MaterialNot Applicable
Includes Auxiliary ContactsYes
Reversing CapabilityNon-Reversing
Mechanical Operating Durability8,000,000
Number of Normally Open Main Contacts3
Horsepower @ Single Phase - 240V AC5 hp
NEMA Enclosure RatingNo Enclosure
Full Load Current - Inductive150 A
PhaseThree
Number of Auxillary Contacts2
Overall Depth5.35 in
Horsepower @ Three Phase - 600V AC125 hp
Mounting StyleDIN Rail, Plate
Embedded Surge SuppressorYes
Resistance PropertiesFire Resistant, Insulation Resistant
Minimum Operating Temperature-40 Degrees F
Electrical Operating Durability1,000,000, 850,000
Maximum Operating Temperature140 Degrees F
Country of Origin (subject to change)Czechia
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#480 V AC
#150 A
#Reversing: No
#SCHNEIDER
#Mfr LC1D150T7
#SCHNEIDER
#GRG2432473
#mfr:LC1D150T7
#part number:LC1D150T7
#pn:LC1D150T7
#part code:LC1D150T7
#item number:LC1D150T7
#product code:LC1D150T7
#manufacturer number:LC1D150T7
#manufacturers part number:LC1D150T7
#mfn:LC1D150T7

Reviews

There are no reviews yet.

Add a review