Full Load Amps-Inductive | 150 A |
Item | IEC Magnetic Contactor |
Action | Non-Reversing |
Full Load Amps-Resistive | 200 A |
Number of Poles | 3 |
Coil Volts | 480 V AC |
Reversing | No |
Height | 4.33 in |
Width | 4.33 in |
HP @ 3 Phase - 208V | 40 hp |
HP @ 3 Phase - 575V | 125 hp |
Depth | 5.12 in |
HP @ 3 Phase - 240V | 50 hp |
Enclosure NEMA Rating | No Enclosure |
HP @ 3 Phase - 480V | 100 hp |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Auxiliary Contact Form | 1NO/1NC |
Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
NEMA Size | Not Applicable |
Series | TeSys Deca |
Fire Rating | UL 94 V1 |
Electrical Durability | 0.85 Mcycles (150 A, AC-3, Less than 440 V), 1 Mcycles (200 A, AC-1, Less than 440 V), 0.85 Mcycles (150 A, AC-3e, Less than 440 V) |
Inrush VA | 280 to 350 VA |
Net Weight | 2.5 kg |
Rated Short-Time Withstand Current | 250 A (at 40°C for 10 min Power Circuit), 580 A (at 40°C for 1 min Power Circuit), 1200 A (at 40°C for 10 s Power Circuit), 1400 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Operating Time | 20 to 35 ms (Closing), 40 to 75 ms (Opening) |
Switching Voltage | 17 V (Signalling Circuit) |
Working Height | Up to 9842.52 ft |
Watts Loss | 3 to 4.5W |
IP Rating | IP20 |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1660 A @ 440V (Power Circuit) |
Max. Temperature | 850°C |
Impulse Withstand Voltage | 8 kV |
Rated Breaking Capacity | 1400 A @ 440V |
Thermal Amperage | 200 A (at 60°C Power Circuit) |
Mechanical Durability | 8 Mcycles |
Signalling Circuit Frequency | 25 to 400 Hz |
Switching Current | 5 mA (Signalling Circuit) |
Application | Motor Control, Resistive Load |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open) |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Rated Insulation Volts | 600/1000V (Power Circuit), 600/690V (Signalling Circuit) |
Mounts On | Plate, Rail |
Overvoltage Category | CAT III |
Impedance | 0.6 mOhm |
Hold VA | 2 to 18 VA |
Rated Voltage | 1000V AC, 300V DC |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Electrical Connection | Screw Clamp Terminals |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.5 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.15 Uc (at -40-55°C 50/60 Hz), 1 to 1.15 Uc (at 55-70°C 50/60 Hz) |
Features | Built-In Bi-Directional Peak Limiting Diode Suppressor |
Fuse Amps | 10 A (Signalling Circuit), 315 A (Type 1 Power Circuit), 250 A (Type 2 Power Circuit) |
Max. Operating Watts | 40 kW (at 220 to 230V AC 50/60 Hz AC-3), 75 kW (at 380 to 400V AC 50/60 Hz AC-3), 80 kW 415 to (at 440V AC 50/60 Hz AC-3), 90 kW (at 500V AC 50/60 Hz AC-3), 100 kW (at 660 to 690V AC 50/60 Hz AC-3), 75 kW (at 1000V AC 50/60 Hz AC-3), 22 kW (at 400V AC 50/60 Hz AC-4), 40 kW (at 220 to 230V AC 50/60 Hz AC-3e), 75 kW (at 380 to 400V AC 50/60 Hz AC-3e), 80 kW (at 415 to 440V AC 50/60 Hz AC-3e), 90 kW (at 500V AC 50/60 Hz AC-3e), 100 kW (at 660 to 690V AC 50/60 Hz AC-3e), 75 kW (at 1000V AC 50/60 Hz AC-3e) |
Tightening Torque | 1.2 Nm (Control Circuit), 12 Nm (Power Circuit) |
Includes Protective Cover | Yes |
Environmental Attributes | Mercury Free, PVC Free, Pollution Degree 3 |
Non-Overlap Time | 1.5 ms |
Operating Speed | 1200 cycles per hr |
Maximum Voltage Rating | 1000V AC |
Contactor Style | IEC |
Overall Width | 0.47 in |
Frequency | 50/60 Hz |
Horsepower @ Three Phase - 480V AC | 100 hp |
Horsepower @ Three Phase - 208V AC | 40 hp |
Coil Voltage | 480V AC |
Terminal Connection Type | Screw Clamp Terminals |
Horsepower @ Three Phase - 240V AC | 50 hp |
Overall Height | 6.22 in |
Full Load Current - Resistive | 200 A |
NEMA Enclosure Material | Not Applicable |
Includes Auxiliary Contacts | Yes |
Reversing Capability | Non-Reversing |
Mechanical Operating Durability | 8,000,000 |
Number of Normally Open Main Contacts | 3 |
Horsepower @ Single Phase - 240V AC | 5 hp |
NEMA Enclosure Rating | No Enclosure |
Full Load Current - Inductive | 150 A |
Phase | Three |
Number of Auxillary Contacts | 2 |
Overall Depth | 5.35 in |
Horsepower @ Three Phase - 600V AC | 125 hp |
Mounting Style | DIN Rail, Plate |
Embedded Surge Suppressor | Yes |
Resistance Properties | Fire Resistant, Insulation Resistant |
Minimum Operating Temperature | -40 Degrees F |
Electrical Operating Durability | 1,000,000, 850,000 |
Maximum Operating Temperature | 140 Degrees F |
Country of Origin (subject to change) | Czechia |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 480 V AC, 150 A, Reversing: No, SCHNEIDER, Mfr# LC1D150T7
$720.70
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 480V AC, Number of Poles 3, Full Load Current - Inductive 150 A, Full Load Current - Resistive 200 A, Reversing Capability Non-Reversing, Overall Height 6.22 in, Overall Width 0.47 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
Out of stock
You must be logged in to post a review.
Reviews