IEC Magnetic Contactor, 3 Poles, 120 V AC, 50 A, SCHNEIDER ELECTRIC, Mfr# LC2D50G7

$981,99

Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 120V AC, Number of Poles 3, Full Load Current - Inductive 50 A, Full Load Current - Resistive 80 A, Reversing Capability Reversing, Overall Height 5.2 in, Overall Width 6.5 in, Terminal Connection Type Screw Clamp Terminals, Series TeSys Deca, Number of Auxillary Contacts 3, Contactor Style IEC, Maximum Voltage Rating 120V AC, Embedded Surge Suppressor No

Out of stock

Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC2D50G7
Availability: Ships in 1 days
SKU: GRG0568508 Category:
Full Load Amps-Inductive50 A
ItemIEC Magnetic Contactor
ActionReversing
Number of Poles3
Coil Volts120 V AC
Height132 mm
Width165 mm
Depth142 mm
Aux. Contact Configuration1NO/1NC
NEMA SizeNot Applicable
Auxiliary Contact Form1NO/1NC
StandardsCSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508
SeriesTeSys Deca
Watts Loss6 to 10W
Switching Voltage17 V (Control Circuit)
Inrush VA200 to 220 VA
Fire RatingUL 94 V1
Includes Protective CoverYes
Non-Overlap Time1.5 ms
Operating Speed3600 cycles per hr
ApplicationMotor Control
Vibration Resistance3 G (Contactor Closed), 2 G (Contactor Open)
Max. Operating Watts15 kW (at 220 to 240V AC 50/60 Hz), 22 kW (at 380 to 400V AC 50/60 Hz), 25 kW (at 415V AC 50/60 Hz), 30 kW (at 440V AC 50/60 Hz), 30 kW (at 500V AC 50/60 Hz), 33 kW (at 660 to 690V AC 50/60 Hz)
Fuse Amps10 A (Control Circuit), 100 A (Type 1 and 2 Power Circuit)
Insulation Resistance RangeGreater Than 10 Mohms (Control Circuit)
Rated Voltage1000V AC
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free
Rated Making Capacity140 A (AC Control Circuit), 900 A @ 440V (Power Circuit)
FeaturesWithout Built-In Bi-Directional Peak Limiting Diode Suppressor
Control Circuit Voltage LimitsDrop-Out: 0.3 to 0.6 Uc (at 60°C 50/60 Hz), Operational: 0.8 to 1.1 Uc (at 60°C 50 Hz), 0.85 to 1.1 Uc (at 60°C 60 Hz)
Switching Current5 mA (Control Circuit)
Shock Resistance10 G (Contactor Closed), 8 G (Contactor Open)
Hold VA20 to 26 VA (at 50 Hz 20°C), 22 to 26 VA (at 60 Hz 20°C)
Max. Temperature850°C
Thermal Amperage10 A (at 60°C Control Circuit), 80 A (at 60°C Power Circuit)
Working Height9842.52 ft
Net Weight2.4 kg
Rated Insulation Volts600/690V
IP RatingIP20
Mechanical Durability6 Mcycles
Tightening Torque1.7 Nm (Control Circuit), 5 to 8 Nm (Power Circuit)
Rated Breaking Capacity900 A @ 440V
Operating Time12 to 26 ms (Closing), 4 to 19 ms (Opening)
Mounts OnPlate, Rail
Overvoltage CategoryCAT III
Impulse Withstand Voltage6 kV
Includes Auxiliary ContactsYes
Overall Depth5.59 in
Maximum Operating Temperature140 Degrees F
NEMA Enclosure RatingNo Enclosure
Embedded Surge SuppressorNo
Number of Normally Open Main Contacts1
Overall Height5.2 in
Mechanical Operating Durability6,000,000
Number of Normally Closed Main Contacts0
Terminal Connection TypeScrew Clamp Terminals
Frequency60 Hz
Contactor StyleIEC
Coil Voltage120V AC
Full Load Current - Resistive80 A
Reversing CapabilityReversing
Minimum Operating Temperature23 Degrees F
Maximum Voltage Rating120V AC
Full Load Current - Inductive50 A
Overall Width6.5 in
Number of Auxillary Contacts3
IP Degree Of ProtectionIP2X IEC 60529, IP2X VDE 0106
Ambient Air Temperature For Operation23 to 140°F (-5 to 60°C)
Control Circuit TypeAC
Rated Insulation VoltageControl circuit 600 V CSA, Control circuit 600 V UL, Power circuit 600 V CSA, Power circuit 600 V UL, Control circuit 690 V IEC 60947-1, Power circuit 690 V IEC 60947-1
Hold-In Power Consumption in VA20 VA 50 Hz cos phi 0.3 (at 68°F (20°C)), 22 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 26 VA 50 Hz cos phi 0.3 (at 68°F (20°C)), 26 VA 60 Hz cos phi 0.3 (at 68°F (20°C))
Power Dissipation Per Pole3.7 W AC-3 - Ith 80 A
Assembly StyleReady assembled
Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
Insulation ResistanceGreater than 10 MOhm for control circuit
Maximum Operating Rate3600 cyc/h 140°F (60°C)
Permissible Ambient Air Temperature Around The Device-40 to 158°F (-40 to 70°C) at Uc
Flame RetardanceV1 conforming to UL 94
Rated Operational CurrentPower circuit 50 A AC AC-3 140°F (60°C))
Auxiliary Contact Composition1 NO + 1 NC
Utilisation CategoryAC-2, AC-3, AC-4
Product CertificationsGL, UL, RINA, GOST, CSA, LROS (Lloyds register of shipping), CCC, DNV, BV, UKCA
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
IRMS Rated Making Capacity140 A AC for control circuit conforming to IEC 60947-5-1, 900 A at 440 V for power circuit conforming to IEC 60947
Operating Altitude9842.52 ft (3000 m) without derating
Poles Description3P
Ambient Air Temperature For Storage-76 to 176°F (-60 to 80°C)
Conventional Free Air Thermal Current10 A (at 140°F (60°C)) for control circuit, 80 A (at 140°F (60°C)) for power circuit
Protective CoverWith
Connections - TerminalsControl circuit 1 0.00 to 0.01 in? (1 to 4 mm?)flexible with cable end, Control circuit 1 0.00 to 0.01 in? (1 to 4 mm?)flexible without cable end, Control circuit 1 0.00 to 0.01 in? (1 to 4 mm?)solid without cable end, Control circuit 2 0.00 to 0.00 in? (1 to 2.5 mm?)flexible with cable end, Control circuit 2 0.00 to 0.01 in? (1 to 4 mm?)flexible without cable end, Control circuit 2 0.00 to 0.01 in? (1 to 4 mm?)solid without cable end, Power circuit 1 0.00 to 0.05 in? (1 to 35 mm?)flexible with cable end, Power circuit 1 0.00 to 0.05 in? (1 to 35 mm?)flexible without cable end, Power circuit 1 0.00 to 0.05 in? (1 to 35 mm?)solid without cable end, Power circuit 2 0.00 to 0.04 in? (1 to 25 mm?)flexible with cable end, Power circuit 2 0.00 to 0.04 in? (1 to 25 mm?)flexible without cable end, Power circuit 2 0.00 to 0.04 in? (1 to 25 mm?)solid without cable end, Power circuit 2 0.00 to 0.05 in? (1 to 35 mm?)flexible with cable end, Power circuit 2 0.00 to 0.05 in? (1 to 35 mm?)flexible without cable end, Power circuit 2 0.00 to 0.05 in? (1 to 35 mm?)solid without cable end
Inrush Power in VA200 VA cos phi 0.75 (at 68°F (20°C)), 220 VA cos phi 0.75 (at 68°F (20°C))
Product Or Component TypeReversing contactor
Coil TechnologyWithout built-in bidirectional peak limiting diode suppressor
Mounting SupportPlate, Rail
Rated Operational VoltagePower circuit Less than or Equal to 1000 V AC 25 to 400 Hz
Interlocking TypeMechanical
Fire Resistance1562°F (850°C) IEC 60695-2-1
Coil TypeStandard
Minimum Switching Voltage17 V for control circuit
Control Circuit Voltage120 V AC 60 Hz
Associated Fuse Rating10 A gG for control circuit conforming to IEC 60947-5-1, 100 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 100 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Pole Contact Composition3 NO
Protective TreatmentTH 3)IEC 60068
Minimum Switching Current5 mA for control circuit
Motor Power KW15 kW 220 to 240 V AC 50/60 Hz, 22 kW 380 to 400 V AC 50/60 Hz, 25 kW 415 V AC 50/60 Hz, 30 kW 440 V AC 50/60 Hz, 30 kW 500 V AC 50/60 Hz, 33 kW 660 to 690 V AC 50/60 Hz
Rated Impulse Withstand Voltage6 kV IEC 60947
Heat Dissipation6 to 10 W at 50/60 Hz for control circuit
Average Impedance80 A 50 Hz for power circuit
Country of Origin (subject to change)Czechia
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#120 V AC
#50 A
#SCHNEIDER ELECTRIC
#Mfr LC2D50G7
#SCHNEIDER ELECTRIC
#GRG0568508
#mfr:LC2D50G7
#part number:LC2D50G7
#pn:LC2D50G7
#part code:LC2D50G7
#item number:LC2D50G7
#product code:LC2D50G7
#manufacturer number:LC2D50G7
#manufacturers part number:LC2D50G7
#mfn:LC2D50G7

Reviews

There are no reviews yet.

Add a review