Discount -3%

IEC Magnetic Contactor, 3 Poles, 208 V AC, 80 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D80L6

$403.51

Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 200V AC, Number of Poles 3, Full Load Current - Inductive 80 A, Full Load Current - Resistive 125 A, Reversing Capability Non-Reversing, Overall Height 5 in, Overall Width 3.35 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$403.51
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC1D80L6
Availability: Ships in 1 days
SKU: GRG0896637 Category:
Full Load Amps-Inductive80 A
ItemIEC Magnetic Contactor
Full Load Amps-Resistive125 A
ActionNon-Reversing
Number of Poles3
Coil Volts208 V AC
ReversingNo
HP @ 1 Phase - 230V15
HP @ 1 Phase - 120V7 1/2 hp
HP @ 1 Phase - 240V15 hp
Height5 in
HP @ 3 Phase - 208V30 hp
Width3.34 in
Depth5.12 in
HP @ 3 Phase - 240V30 hp
HP @ 3 Phase - 575V60 hp
HP @ 3 Phase - 480V60 hp
Enclosure NEMA RatingNo Enclosure
Aux. Contact Configuration1NO/1NC
Hz50/60
Auxiliary Contact Form1NO/1NC
StandardsBV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UL 508, UL Listed
Frame / Series / Class / CodeTeSys
SeriesTeSys Deca
NEMA SizeNot Applicable
Shock Resistance10 G for 11 ms (Contactor Closed), 8 G for 11 ms (Contactor Open)
Control Circuit Voltage LimitsOperational AC: 0.85 to 1.1 Uc (at -40 to 55°C 60 Hz), 1 to 1.1 Uc (at 55 to 70°C 60 Hz), Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 60 Hz)
Rated Insulation Volts600/1000V (Power Circuit), 600/690V (Signalling Circuit)
Max. Temperature850°C
Mechanical Durability10 Mcycles
Watts Loss6 to 10W
Impedance0.8 mOhm
Fire RatingUL 94 V1
Electrical ConnectionScrew Clamp Terminals
Inrush VA220 VA
Fuse Amps10 A (Signalling Circuit), 200 A (Type 1 Power Circuit), 160 A (Type 2 Power Circuit)
Impulse Withstand Voltage8 kV
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1100 A @ 440V (Power Circuit)
Signalling Circuit Frequency25 to 400 Hz
FeaturesWithout Built-In Suppressor Module
Hold VA22 VA
Net Weight1.59 kg
Working HeightUp to 9842.52 ft
IP RatingIP20
Rated Voltage690V AC, 300V DC
Mounts OnPlate, Rail
Overvoltage CategoryCAT III
Max. Operating Watts22 kW (at 220 to 230V AC 50/60 Hz AC-3), 37 kW (at 380 to 400V AC 50/60 Hz AC-3), 45 kW (at 415 to 440V AC 50/60 Hz AC-3), 55 kW (at 500V AC 50/60 Hz AC-3), 45 kW (at 660 to 690V AC 50/60 Hz AC-3), 15 kW (at 400V AC 50/60 Hz AC-4), 22 kW (at 220 to 230V AC 50/60 Hz AC-3e), 37 kW (at 380 to 400V AC 50/60 Hz AC-3e), 45 kW (at 415 to 440V AC 50/60 Hz AC-3e), 55 kW (at 500V AC 50/60 Hz AC-3e), 45 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Rated Short-Time Withstand Current640 A (at 40°C for 10 s Power Circuit), 990 A (at 40°C for 1 s Power Circuit), 135 A (at 40°C for 10 min Power Circuit), 320 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Operating Time20 to 35 ms (Closing), 6 to 20 ms (Opening)
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Thermal Amperage10 A (at 60°C Signalling Circuit), 125 A (at 60°C Power Circuit)
Operating Speed3600 cycles per hr
Switching Current5 mA (Signalling Circuit)
Electrical Durability0.8 Mcycles (125 A, AC-1, Less than 440 V), 1.5 Mcycles (80 A, AC-3, Less than 440 V), 1.5 Mcycles (80 A, AC-3e, Less than 440 V)
Rated Breaking Capacity1100 A @ 440V
Includes Protective CoverYes
Tightening Torque1.2 Nm (Control Circuit), 12 Nm (Power Circuit)
Switching Voltage17 V (Signalling Circuit)
Non-Overlap Time1.5 ms
Vibration Resistance3 G (Contactor Closed), 2 G (Contactor Open)
ApplicationMotor Control, Resistive Load
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Horsepower @ Three Phase - 600V AC60 hp
Maximum Voltage Rating300V DC
Number of Normally Open Main Contacts3
Maximum Operating Temperature140 Degrees F
Contactor StyleIEC
Coil Voltage200V AC
Overall Depth5.12 in
Electrical Operating Durability1,500,000, 800,000
Number of Auxillary Contacts2
Embedded Surge SuppressorNo
PhaseThree
NEMA Enclosure RatingNo Enclosure
Frequency60 Hz
Horsepower @ Single Phase - 240V AC15 hp
NEMA Enclosure MaterialNot Applicable
Reversing CapabilityNon-Reversing
Mounting StyleDIN Rail, Plate
Minimum Operating Temperature-40 Degrees F
Horsepower @ Three Phase - 208V AC30 hp
Includes Auxiliary ContactsYes
Mechanical Operating Durability10,000,000
Resistance PropertiesFire Resistant, Insulation Resistant
Horsepower @ Three Phase - 240V AC30 hp
Horsepower @ Three Phase - 480V AC60 hp
Full Load Current - Resistive125 A
Overall Height5 in
Full Load Current - Inductive80 A
Horsepower @ Single Phase - 120V AC7 1/2 hp
Overall Width3.35 in
Terminal Connection TypeScrew Clamp Terminals
Country of Origin (subject to change)Czechia
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#208 V AC
#80 A
#Reversing: No
#SCHNEIDER ELECTRIC
#Mfr LC1D80L6
#SCHNEIDER ELECTRIC
#GRG0896637
#mfr:LC1D80L6
#part number:LC1D80L6
#pn:LC1D80L6
#part code:LC1D80L6
#item number:LC1D80L6
#product code:LC1D80L6
#manufacturer number:LC1D80L6
#manufacturers part number:LC1D80L6
#mfn:LC1D80L6

Reviews

There are no reviews yet.

Add a review