Discount -3%

IEC Magnetic Contactor, 3 Poles, 24 V AC, 80 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D80B7

$403.51

Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V AC, Number of Poles 3, Full Load Current - Inductive 80 A, Full Load Current - Resistive 125 A, Reversing Capability Non-Reversing, Overall Height 5 in, Overall Width 3.35 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$403.51
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC1D80B7
Availability: Ships in 1 days
SKU: GRG2029903 Category:
ItemIEC Magnetic Contactor
Full Load Amps-Inductive80 A
ActionNon-Reversing
Full Load Amps-Resistive125 A
Number of Poles3
Coil Volts24 V AC
ReversingNo
HP @ 1 Phase - 120V7 1/2 hp
HP @ 1 Phase - 230V15
HP @ 1 Phase - 240V15 hp
Height5 in
Width3.34 in
HP @ 3 Phase - 208V30 hp
HP @ 3 Phase - 240V30 hp
Depth5.12 in
HP @ 3 Phase - 575V60 hp
HP @ 3 Phase - 480V60 hp
Enclosure NEMA RatingNo Enclosure
Aux. Contact Configuration1NO/1NC
Hz50/60
StandardsBV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UL 508, UL Listed
Frame / Series / Class / CodeTeSys
Auxiliary Contact Form1NO/1NC
SeriesTeSys Deca
NEMA SizeNot Applicable
Max. Temperature850°C
Impedance0.8 mOhm
IP RatingIP20
Fuse Amps10 A (Signalling Circuit), 200 A (Type 1 Power Circuit), 160 A (Type 2 Power Circuit)
Rated Breaking Capacity1100 A @ 440V
Electrical ConnectionScrew Clamp Terminals
Watts Loss6 to 10W
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Hold VA26 VA
Rated Short-Time Withstand Current640 A (at 40°C for 10 s Power Circuit), 990 A (at 40°C for 1 s Power Circuit), 135 A (at 40°C for 10 min Power Circuit), 320 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Max. Operating Watts22 kW (at 220 to 230V AC 50/60 Hz AC-3), 37 kW (at 380 to 400V AC 50/60 Hz AC-3), 45 kW (at 415 to 440V AC 50/60 Hz AC-3), 55 kW (at 500V AC 50/60 Hz AC-3), 45 kW (at 660 to 690V AC 50/60 Hz AC-3), 15 kW (at 400V AC 50/60 Hz AC-4), 22 kW (at 220 to 230V AC 50/60 Hz AC-3e), 37 kW (at 380 to 400V AC 50/60 Hz AC-3e), 45 kW (at 415 to 440V AC 50/60 Hz AC-3e), 55 kW (at 500V AC 50/60 Hz AC-3e), 45 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Rated Voltage690V AC, 300V DC
Includes Protective CoverYes
Rated Insulation Volts600/1000V (Power Circuit), 600/690V (Signalling Circuit)
Signalling Circuit Frequency25 to 400 Hz
Impulse Withstand Voltage8 kV
Vibration Resistance3 G (Contactor Closed), 2 G (Contactor Open)
Mechanical Durability4 Mcycles
Operating Time20 to 35 ms (Closing), 6 to 20 ms (Opening)
Control Circuit Voltage LimitsOperational AC: 0.85 to 1.1 Uc (at -40 to 55°C 60 Hz), 0.8 to 1.1 Uc (at -40 to 55°C 50 Hz), 1 to 1.1 Uc (at 55 to 70°C 50/60 Hz), Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz)
Switching Current5 mA (Signalling Circuit)
Net Weight1.59 kg
Inrush VA245 VA
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
ApplicationMotor Control, Resistive Load
Non-Overlap Time1.5 ms
Overvoltage CategoryCAT III
FeaturesWithout Built-In Suppressor Module
Thermal Amperage10 A (at 60°C Signalling Circuit), 125 A (at 60°C Power Circuit)
Electrical Durability0.8 Mcycles (125 A, AC-1, Less than 440 V), 1.5 Mcycles (80 A, AC-3, Less than 440 V), 1.5 Mcycles (80 A, AC-3e, Less than 440 V)
Tightening Torque1.2 Nm (Control Circuit), 12 Nm (Power Circuit)
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1100 A @ 440V (Power Circuit)
Fire RatingUL 94 V1
Mounts OnPlate, Rail
Working HeightUp to 9842.52 ft
Operating Speed3600 cycles per hr
Shock Resistance10 G for 11 ms (Contactor Closed), 8 G for 11 ms (Contactor Open)
Switching Voltage17 V (Signalling Circuit)
Horsepower @ Single Phase - 240V AC15 hp
Terminal Connection TypeScrew Clamp Terminals
Horsepower @ Three Phase - 240V AC30 hp
Maximum Voltage Rating300V DC
Resistance PropertiesFire Resistant, Insulation Resistant
Frequency50/60 Hz
Maximum Operating Temperature140 Degrees F
Electrical Operating Durability1,500,000, 800,000
Horsepower @ Three Phase - 480V AC60 hp
PhaseThree
Minimum Operating Temperature-40 Degrees F
Number of Normally Open Main Contacts3
Overall Depth5.12 in
Horsepower @ Three Phase - 208V AC30 hp
Full Load Current - Resistive125 A
NEMA Enclosure MaterialNot Applicable
Number of Auxillary Contacts2
Overall Width3.35 in
Coil Voltage24V AC
Includes Auxiliary ContactsYes
Embedded Surge SuppressorNo
Horsepower @ Three Phase - 600V AC60 hp
NEMA Enclosure RatingNo Enclosure
Horsepower @ Single Phase - 120V AC7 1/2 hp
Reversing CapabilityNon-Reversing
Mounting StyleDIN Rail, Plate
Contactor StyleIEC
Full Load Current - Inductive80 A
Mechanical Operating Durability4,000,000
Overall Height5 in
Country of Origin (subject to change)Czechia
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#24 V AC
#80 A
#Reversing: No
#SCHNEIDER ELECTRIC
#Mfr LC1D80B7
#SCHNEIDER ELECTRIC
#GRG2029903
#mfr:LC1D80B7
#part number:LC1D80B7
#pn:LC1D80B7
#part code:LC1D80B7
#item number:LC1D80B7
#product code:LC1D80B7
#manufacturer number:LC1D80B7
#manufacturers part number:LC1D80B7
#mfn:LC1D80B7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!