Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 25 A |
Action | Non-Reversing |
Full Load Amps-Resistive | 40 A |
Number of Poles | 3 |
Coil Volts | 480 V AC |
Reversing | No |
HP @ 1 Phase - 230V | 3 |
HP @ 1 Phase - 120V | 2 hp |
Height | 3.36 in |
HP @ 1 Phase - 240V | 3 hp |
Width | 1.77 in |
HP @ 3 Phase - 208V | 7 1/2 hp |
HP @ 3 Phase - 240V | 7 1/2 hp |
Depth | 3.62 in |
HP @ 3 Phase - 575V | 20 hp |
Enclosure NEMA Rating | No Enclosure |
HP @ 3 Phase - 480V | 15 hp |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Auxiliary Contact Form | 1NO/1NC |
Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
Frame / Series / Class / Code | TeSys |
Series | TeSys Deca |
NEMA Size | Not Applicable |
Inrush VA | 70 VA |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 40 A (at 60°C Power Circuit) |
Overvoltage Category | CAT III |
Application | Motor Control, Resistive Load |
Operating Speed | 3600 cycles per hr |
Shock Resistance | 8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed) |
Watts Loss | 2 to 3W |
Rated Insulation Volts | 600/690V |
Signalling Circuit Frequency | 25 to 400 Hz |
Electrical Connection | Screw Clamp Terminals |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Rated Short-Time Withstand Current | 240 A (at 40°C for 10 s Power Circuit), 380 A (at 40°C for 1 s Power Circuit), 50 A (at 40°C for 10 min Power Circuit), 120 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Fire Rating | UL 94 V1 |
Operating Time | 12 to 22 ms (Closing), 4 to 19 ms (Opening) |
Rated Breaking Capacity | 450 A @ 440V |
Features | Without Built-In Suppressor Module |
Electrical Durability | 1.65 Mcycles (25 A, AC-3, Less than 440 V), 1.4 Mcycles (40 A, AC-1, Less than 440 V), 1.65 Mcycles (25 A, AC-3e, Less than 440 V) |
Impedance | 2 mOhm |
Working Height | Up to 9842.52 ft |
Max. Operating Watts | 5.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 11 kW (at 380 to 400V AC 50/60 Hz AC-3), 11 kW (at 415 to 440V AC 50/60 Hz AC-3), 15 kW (at 500V AC 50/60 Hz AC-3), 15 kW (at 660 to 690V AC 50/60 Hz AC-3), 5.5 kW (at 400V AC 50/60 Hz AC-4), 5.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 11 kW (at 380 to 400V AC 50/60 Hz AC-3e), 11 kW (at 415 to 440V AC 50/60 Hz AC-3e), 15 kW (at 500V AC 50/60 Hz AC-3e), 15 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit) |
Non-Overlap Time | 1.5 ms |
Net Weight | 0.37 kg |
Impulse Withstand Voltage | 6 kV |
Switching Current | 5 mA (Signalling Circuit) |
IP Rating | IP20 |
Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Mounts On | Plate, Rail |
Max. Temperature | 850°C |
Rated Voltage | 690V AC, 300V DC |
Mechanical Durability | 15 Mcycles |
Includes Protective Cover | Yes |
Switching Voltage | 17 V (Signalling Circuit) |
Fuse Amps | 10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 40 A (Type 2 Power Circuit) |
Tightening Torque | 1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit) |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
Full Load Current - Resistive | 40 A |
Full Load Current - Inductive | 25 A |
Contactor Style | IEC |
Horsepower @ Three Phase - 600V AC | 20 hp |
Overall Height | 3.35 in |
Embedded Surge Suppressor | No |
NEMA Enclosure Rating | No Enclosure |
Resistance Properties | Fire Resistant, Insulation Resistant |
Maximum Operating Temperature | 140 Degrees F |
Electrical Operating Durability | 1,400,000, 1,650,000 |
NEMA Enclosure Material | Not Applicable |
Mechanical Operating Durability | 15,000,000 |
Overall Width | 1.77 in |
Minimum Operating Temperature | -40 Degrees F |
Frequency | 50/60 Hz |
Coil Voltage | 480V AC |
Reversing Capability | Non-Reversing |
Horsepower @ Single Phase - 240V AC | 3 hp |
Maximum Voltage Rating | 690V AC |
Number of Normally Open Main Contacts | 3 |
Overall Depth | 3.62 in |
Mounting Style | DIN Rail, Plate |
Terminal Connection Type | Screw Clamp Terminals |
Horsepower @ Three Phase - 240V AC | 7 1/2 hp |
Includes Auxiliary Contacts | Yes |
Horsepower @ Single Phase - 120V AC | 2 hp |
Phase | Three |
Number of Auxillary Contacts | 2 |
Horsepower @ Three Phase - 480V AC | 15 hp |
Horsepower @ Three Phase - 208V AC | 7 1/2 hp |
Connections - Terminals | Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (1 to 10 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 6 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (1.5 to 10 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: solid without cable end |
Utilisation Category | AC-3, AC-1, AC-4, AC-3e |
Control Circuit Voltage | 480 V AC 50/60 Hz |
Pole Contact Composition | 3 NO |
Minimum Switching Voltage | 17 V for signalling circuit |
Maximum Operating Rate | 3600 cyc/h 140°F (60°C) |
IP Degree Of Protection | IP20 front face IEC 60529 |
Operating Altitude | 0 to 9842.52 ft (0 to 3000 m) |
Product Certifications | DNV, CSA, RINA, GOST, LROS (Lloyds register of shipping), CCC, GL, BV, UL, UKCA |
Inrush Power in VA | 70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C)) |
Poles Description | 3P |
Heat Dissipation | 2 to 3 W at 50/60 Hz |
Pollution Degree | 3 |
Climatic Withstand | IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat |
Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
Mechanical Robustness | Vibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor closed 15 Gn for 11 ms), Shocks contactor open 8 Gn for 11 ms) |
Conventional Free Air Thermal Current | 10 A (at 140°F (60°C)) for signalling circuit, 40 A (at 140°F (60°C)) for power circuit |
Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1 |
Permissible Ambient Air Temperature Around The Device | -40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating |
Rated Insulation Voltage | Power circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL |
Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1, 63 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 40 A gG at Less than or Equal to 690 V coordination type 2 for power circuit |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
Contactor Application | Motor control, Resistive load |
Auxiliary Contact Composition | 1 NO + 1 NC |
IRMS Rated Making Capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 450 A at 440 V for power circuit conforming to IEC 60947 |
Flame Retardance | V1 conforming to UL 94 |
Product Or Component Type | Contactor |
Motor Power KW | 5.5 kW at 220 to 230 V AC 50/60 Hz (AC-3), 11 kW at 380 to 400 V AC 50/60 Hz (AC-3), 11 kW at 415 to 440 V AC 50/60 Hz (AC-3), 15 kW at 500 V AC 50/60 Hz (AC-3), 15 kW at 660 to 690 V AC 50/60 Hz (AC-3), 5.5 kW at 400 V AC 50/60 Hz (AC-4), 5.5 kW at 220 to 230 V AC 50/60 Hz (AC-3e), 11 kW at 380 to 400 V AC 50/60 Hz (AC-3e), 11 kW at 415 to 440 V AC 50/60 Hz (AC-3e), 15 kW at 500 V AC 50/60 Hz (AC-3e), 15 kW at 660 to 690 V AC 50/60 Hz (AC-3e) |
Protective Treatment | THIEC 60068-2-30 |
Contact Compatibility | M2 |
Compatibility Code | LC1D |
Control Circuit Type | AC 50/60 Hz |
Rated Short Time Withstand Current | 240 A 104°F (40°C) - 10 s for power circuit, 380 A 104°F (40°C) - 1 s for power circuit, 50 A 104°F (40°C) - 10 min for power circuit, 120 A 104°F (40°C) - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit |
Rated Operational Current | 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit |
Maximum Horse Power Rating | 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 2 hp at 115 V AC 50/60 Hz for 1 phase motors, 7.5 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 15 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 20 hp at 575/600 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 200/208 V AC 50/60 Hz for 3 phase motors |
Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC |
Protective Cover | With |
Minimum Switching Current | 5 mA for signalling circuit |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Average Impedance | 2 mOhm - Ith 40 A 50 Hz for power circuit |
Mounting Support | Plate, Rail |
Power Dissipation Per Pole | 3.2 W AC-1, 1.25 W AC-3, 1.25 W AC-3e |
Hold-In Power Consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C)) |
Country of Origin (subject to change) | Indonesia |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 480 V AC, 25 A, Reversing: No, SCHNEIDER, Mfr# LC1D25T7
$169.74
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 480V AC, Number of Poles 3, Full Load Current - Inductive 25 A, Full Load Current - Resistive 40 A, Reversing Capability Non-Reversing, Overall Height 3.35 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$169.74
You must be logged in to post a review.
Reviews
There are no reviews yet.