IEC Magnetic Contactor, 3 Poles, 480 V AC, 25 A, Reversing: No, SCHNEIDER, Mfr# LC1D25T7

$169.74

Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 480V AC, Number of Poles 3, Full Load Current - Inductive 25 A, Full Load Current - Resistive 40 A, Reversing Capability Non-Reversing, Overall Height 3.35 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$169.74
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER
Mfr #: LC1D25T7
Availability: Ships in 1 days
SKU: GRG2244435 Category:
ItemIEC Magnetic Contactor
Full Load Amps-Inductive25 A
ActionNon-Reversing
Full Load Amps-Resistive40 A
Number of Poles3
Coil Volts480 V AC
ReversingNo
HP @ 1 Phase - 230V3
HP @ 1 Phase - 120V2 hp
Height3.36 in
HP @ 1 Phase - 240V3 hp
Width1.77 in
HP @ 3 Phase - 208V7 1/2 hp
HP @ 3 Phase - 240V7 1/2 hp
Depth3.62 in
HP @ 3 Phase - 575V20 hp
Enclosure NEMA RatingNo Enclosure
HP @ 3 Phase - 480V15 hp
Aux. Contact Configuration1NO/1NC
Hz50/60
Auxiliary Contact Form1NO/1NC
StandardsBV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
Frame / Series / Class / CodeTeSys
SeriesTeSys Deca
NEMA SizeNot Applicable
Inrush VA70 VA
Thermal Amperage10 A (at 60°C Signalling Circuit), 40 A (at 60°C Power Circuit)
Overvoltage CategoryCAT III
ApplicationMotor Control, Resistive Load
Operating Speed3600 cycles per hr
Shock Resistance8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Watts Loss2 to 3W
Rated Insulation Volts600/690V
Signalling Circuit Frequency25 to 400 Hz
Electrical ConnectionScrew Clamp Terminals
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Rated Short-Time Withstand Current240 A (at 40°C for 10 s Power Circuit), 380 A (at 40°C for 1 s Power Circuit), 50 A (at 40°C for 10 min Power Circuit), 120 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Fire RatingUL 94 V1
Operating Time12 to 22 ms (Closing), 4 to 19 ms (Opening)
Rated Breaking Capacity450 A @ 440V
FeaturesWithout Built-In Suppressor Module
Electrical Durability1.65 Mcycles (25 A, AC-3, Less than 440 V), 1.4 Mcycles (40 A, AC-1, Less than 440 V), 1.65 Mcycles (25 A, AC-3e, Less than 440 V)
Impedance2 mOhm
Working HeightUp to 9842.52 ft
Max. Operating Watts5.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 11 kW (at 380 to 400V AC 50/60 Hz AC-3), 11 kW (at 415 to 440V AC 50/60 Hz AC-3), 15 kW (at 500V AC 50/60 Hz AC-3), 15 kW (at 660 to 690V AC 50/60 Hz AC-3), 5.5 kW (at 400V AC 50/60 Hz AC-4), 5.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 11 kW (at 380 to 400V AC 50/60 Hz AC-3e), 11 kW (at 415 to 440V AC 50/60 Hz AC-3e), 15 kW (at 500V AC 50/60 Hz AC-3e), 15 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit)
Non-Overlap Time1.5 ms
Net Weight0.37 kg
Impulse Withstand Voltage6 kV
Switching Current5 mA (Signalling Circuit)
IP RatingIP20
Hold VA7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Mounts OnPlate, Rail
Max. Temperature850°C
Rated Voltage690V AC, 300V DC
Mechanical Durability15 Mcycles
Includes Protective CoverYes
Switching Voltage17 V (Signalling Circuit)
Fuse Amps10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 40 A (Type 2 Power Circuit)
Tightening Torque1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit)
Control Circuit Voltage LimitsDrop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Full Load Current - Resistive40 A
Full Load Current - Inductive25 A
Contactor StyleIEC
Horsepower @ Three Phase - 600V AC20 hp
Overall Height3.35 in
Embedded Surge SuppressorNo
NEMA Enclosure RatingNo Enclosure
Resistance PropertiesFire Resistant, Insulation Resistant
Maximum Operating Temperature140 Degrees F
Electrical Operating Durability1,400,000, 1,650,000
NEMA Enclosure MaterialNot Applicable
Mechanical Operating Durability15,000,000
Overall Width1.77 in
Minimum Operating Temperature-40 Degrees F
Frequency50/60 Hz
Coil Voltage480V AC
Reversing CapabilityNon-Reversing
Horsepower @ Single Phase - 240V AC3 hp
Maximum Voltage Rating690V AC
Number of Normally Open Main Contacts3
Overall Depth3.62 in
Mounting StyleDIN Rail, Plate
Terminal Connection TypeScrew Clamp Terminals
Horsepower @ Three Phase - 240V AC7 1/2 hp
Includes Auxiliary ContactsYes
Horsepower @ Single Phase - 120V AC2 hp
PhaseThree
Number of Auxillary Contacts2
Horsepower @ Three Phase - 480V AC15 hp
Horsepower @ Three Phase - 208V AC7 1/2 hp
Connections - TerminalsControl circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (1 to 10 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 6 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (1.5 to 10 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: solid without cable end
Utilisation CategoryAC-3, AC-1, AC-4, AC-3e
Control Circuit Voltage480 V AC 50/60 Hz
Pole Contact Composition3 NO
Minimum Switching Voltage17 V for signalling circuit
Maximum Operating Rate3600 cyc/h 140°F (60°C)
IP Degree Of ProtectionIP20 front face IEC 60529
Operating Altitude0 to 9842.52 ft (0 to 3000 m)
Product CertificationsDNV, CSA, RINA, GOST, LROS (Lloyds register of shipping), CCC, GL, BV, UL, UKCA
Inrush Power in VA70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Poles Description3P
Heat Dissipation2 to 3 W at 50/60 Hz
Pollution Degree3
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Rated Impulse Withstand Voltage6 kV IEC 60947
Fire Resistance1562°F (850°C) IEC 60695-2-1
Mechanical RobustnessVibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor closed 15 Gn for 11 ms), Shocks contactor open 8 Gn for 11 ms)
Conventional Free Air Thermal Current10 A (at 140°F (60°C)) for signalling circuit, 40 A (at 140°F (60°C)) for power circuit
Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
Permissible Ambient Air Temperature Around The Device-40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating
Rated Insulation VoltagePower circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1, 63 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 40 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Contactor ApplicationMotor control, Resistive load
Auxiliary Contact Composition1 NO + 1 NC
IRMS Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 450 A at 440 V for power circuit conforming to IEC 60947
Flame RetardanceV1 conforming to UL 94
Product Or Component TypeContactor
Motor Power KW5.5 kW at 220 to 230 V AC 50/60 Hz (AC-3), 11 kW at 380 to 400 V AC 50/60 Hz (AC-3), 11 kW at 415 to 440 V AC 50/60 Hz (AC-3), 15 kW at 500 V AC 50/60 Hz (AC-3), 15 kW at 660 to 690 V AC 50/60 Hz (AC-3), 5.5 kW at 400 V AC 50/60 Hz (AC-4), 5.5 kW at 220 to 230 V AC 50/60 Hz (AC-3e), 11 kW at 380 to 400 V AC 50/60 Hz (AC-3e), 11 kW at 415 to 440 V AC 50/60 Hz (AC-3e), 15 kW at 500 V AC 50/60 Hz (AC-3e), 15 kW at 660 to 690 V AC 50/60 Hz (AC-3e)
Protective TreatmentTHIEC 60068-2-30
Contact CompatibilityM2
Compatibility CodeLC1D
Control Circuit TypeAC 50/60 Hz
Rated Short Time Withstand Current240 A 104°F (40°C) - 10 s for power circuit, 380 A 104°F (40°C) - 1 s for power circuit, 50 A 104°F (40°C) - 10 min for power circuit, 120 A 104°F (40°C) - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Rated Operational Current25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Maximum Horse Power Rating3 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 2 hp at 115 V AC 50/60 Hz for 1 phase motors, 7.5 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 15 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 20 hp at 575/600 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 200/208 V AC 50/60 Hz for 3 phase motors
Rated Operational VoltagePower circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC
Protective CoverWith
Minimum Switching Current5 mA for signalling circuit
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Average Impedance2 mOhm - Ith 40 A 50 Hz for power circuit
Mounting SupportPlate, Rail
Power Dissipation Per Pole3.2 W AC-1, 1.25 W AC-3, 1.25 W AC-3e
Hold-In Power Consumption in VA7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C))
Country of Origin (subject to change)Indonesia
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#480 V AC
#25 A
#Reversing: No
#SCHNEIDER
#Mfr LC1D25T7
#SCHNEIDER
#GRG2244435
#mfr:LC1D25T7
#part number:LC1D25T7
#pn:LC1D25T7
#part code:LC1D25T7
#item number:LC1D25T7
#product code:LC1D25T7
#manufacturer number:LC1D25T7
#manufacturers part number:LC1D25T7
#mfn:LC1D25T7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!