Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 9 A |
Full Load Amps-Resistive | 20 A |
Number of Poles | 4 |
Coil Volts | 110 V AC |
Height | 58 mm |
Width | 45 mm |
Depth | 57 mm |
Aux. Contact Configuration | 4NO |
Series | LC1K |
Standards | EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, CB Scheme, CCC, UL, CSA, EAC, CE, UKCA, TC IEC 60068, TC DIN 50016 |
Electrical Durability | 0.18 Mcycles (20 A, AC-1, Less than 440 V) |
Working Height | 6561.68 ft |
Shock Resistance | 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open) |
Fuse Amps | 25 A |
Inrush VA | 30 VA |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Fire Rating | UL 94 V1, NF F 16-101, NF F 16-102 |
Net Weight | 0.18 kg |
Mechanical Durability | 10 Mcycles |
Environmental Attributes | Mercury Free, Toxic Heavy Metal Free |
Rated Breaking Capacity | 110 A @ 415V, 440V, 220 to 230V, 380 to 400 V, 80 A @ 500V, 70 A @ 660 to 690V |
IP Rating | IP2X |
Mounts On | Plate, Rail |
Application | Resistive Load |
Signalling Circuit Frequency | Less Than 400 Hz |
Hold VA | 4.5 VA |
Control Circuit Voltage Limits | Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C) |
Electrical Connection | Screw Clamp Terminals |
Operating Time | 10 to 20 ms (Coil De-Energisation and NO Opening), 10 to 20 ms (Coil Energisation and NO Closing) |
Overvoltage Category | CAT III |
Watts Loss | 1.3W |
Thermal Amperage | 20 A (at 50°C Power Circuit) |
Tightening Torque | 0.8 to 1.3 Nm |
Operating Speed | 3600 cycles per hr |
Rated Voltage | 690V AC |
Impedance | 3 mOhm |
Impulse Withstand Voltage | 8 kV |
Rated Short-Time Withstand Current | 90 A (at 50°C for 1 s Power Circuit), 85 A (at 50°C for 5 s Power Circuit), 80 A (at 50°C for 10 s Power Circuit), 60 A (at 50°C for 30 s Power Circuit), 45 A (at 50°C for 1 min Power Circuit), 40 A (at 50°C for 3 min Power Circuit), 20 A (at 50°C for 15 min Power Circuit) |
Rated Insulation Volts | 600/690V |
Rated Making Capacity | 110 A (AC Power Circuit) |
Conventional Free Air Thermal Current | 20 A (at 140°F (60°C)) for power circuit, 10 A (at 122°F (50°C)) for signalling circuit |
Mechanical Robustness | Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27, Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6, Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6 |
Connections - Terminals | screw clamp terminals 1 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 1 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 1 0.00 to 0.00 in? (0.34 to 2.5 mm?)flexible with cable end, screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 2 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 2 0.00 to 0.00 in? (0.34 to 1.5 mm?)flexible with cable end |
Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz, Signalling circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz |
Rated Short Time Withstand Current | 90 A 122°F (50°C) - 1 s for power circuit, 85 A 122°F (50°C) - 5 s for power circuit, 80 A 122°F (50°C) - 10 s for power circuit, 60 A 122°F (50°C) - 30 s for power circuit, 45 A 122°F (50°C) - 1 min for power circuit, 40 A 122°F (50°C) - 3 min for power circuit, 20 A 122°F (50°C) - Greater than or Equal to 15 min for power circuit |
Power Pole Contact Composition | 4 NO |
Associated Fuse Rating | 25 A gG at Less than or Equal to 440 V for power circuit, 25 A aM for power circuit |
Hold-In Power Consumption in VA | 4.5 VA (at 68°F (20°C)) |
Ambient Air Temperature For Storage | -58 to 176°F (-50 to 80°C) |
Protective Treatment | TC IEC 60068, TC DIN 50016 |
Product Or Component Type | Contactor |
Flame Retardance | V1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102 |
Maximum Operating Rate | 3600 cyc/h |
Rated Insulation Voltage | Power circuit 600 V UL 508, Power circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA C22.2 No 14 |
Poles Description | 4P |
Operating Altitude | 6561.68 ft (2000 m) without derating |
Control Circuit Voltage | 110 V AC 50/60 Hz |
Rated Operational Current | 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit |
Heat Dissipation | 1.3 W |
Utilisation Category | AC-1 |
Device Application | Control |
Product Certifications | CB Scheme, CCC, UL, CSA, EAC, CE, UKCA |
Inrush Power in VA | 30 VA (at 68°F (20°C)) |
Control Circuit Type | AC 50/60 Hz |
Mounting Support | Rail, Plate |
Average Impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
IRMS Rated Making Capacity | 110 A AC for power circuit conforming to IEC 60947 |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
IP Degree Of Protection | IP2X VDE 0106 |
Country of Origin (subject to change) | Multiple |
Package Quantity | 1 |
IEC Magnetic Contactor, 4 Poles, 110 V AC, 9 A, SCHNEIDER ELECTRIC, Mfr# LC1K09004F7
$81,49
Free shipping will be applied on orders over $50
IEC Magnetic Contactor
Out of stock
You must be logged in to post a review.
Reviews
There are no reviews yet.