IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 120V AC, Number of Poles 4, Full Load Current - Inductive 25 A, Full Load Current - Resistive 40 A, Reversing Capability Non-Reversing, Overall Height 4.13 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC, Maximum Voltage Rating 690V AC

9999 in stock

Must order in multiples of 1
Subtotal:
$245.40
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC1D258G7
Availability: Ships in 1 days
SKU: GRG0478311 Category:
Full Load Amps-Inductive25 A
ItemIEC Magnetic Contactor
Full Load Amps-Resistive40 A
Number of Poles4
Coil Volts120 V AC
ReversingNo
Height4.13 in
Width1.77 in
Depth3.9 in
Enclosure NEMA RatingNo Enclosure
Aux. Contact Configuration1NO/1NC
Hz50/60
NEMA SizeNot Applicable
Frame / Series / Class / CodeTeSys
StandardsCB, CCC, CSA, CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, EAC, EN 60947-4-1, EN 60947-5-1, EU-RO-MR by DNV-GL, GB/T 14048.4, IEC 60947-4-1, IEC 60947-5-1, UKCA, UL 60947-5-1, UL Listed, UL 60947-4-1
SeriesTeSys Deca
Auxiliary Contact Form1NO/1NC
Electrical Durability1.4 Mcycles (40 A, AC-1, Less than 440 V)
Fire RatingUL 94 V1
Rated Insulation Volts600/690V
ApplicationResistive Load
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit)
Tightening Torque1.7 Nm (Control Circuit), 1.8 Nm (Power Circuit)
FeaturesWithout Built-In Suppressor Module
Hold VA7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Non-Overlap Time1.5 ms
Thermal Amperage10 A (at 60°C Signalling Circuit), 40 A (at 60°C Power Circuit)
IP RatingIP20
Max. Temperature850°C
Rated Breaking Capacity450 A @ 440V
Electrical ConnectionScrew Clamp Terminals
Rated Short-Time Withstand Current240 A (at 40°C for 10 s Power Circuit), 380 A (at 40°C for 1 s Power Circuit), 50 A (at 40°C for 10 min Power Circuit), 120 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Impulse Withstand Voltage6 kV
Impedance2 mOhm
Working HeightUp to 9842.52 ft
Switching Current5 mA (Signalling Circuit)
Rated Voltage690V AC
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Operating Speed3600 cycles per hr
Switching Voltage17 V (Signalling Circuit)
Shock Resistance8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Control Circuit Voltage LimitsDrop-Out AC: 0.3 to 0.6 Uc (at -40 to 60°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz)
Fuse Amps10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 40 A (Type 2 Power Circuit)
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Watts Loss2 to 3W
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Inrush VA70 VA
Mechanical Durability15 Mcycles
Overvoltage CategoryCAT III
Includes Protective CoverYes
Net Weight0.425 kg
Signalling Circuit Frequency25 to 400 Hz
Operating Time12 to 22 ms (Closing), 4 to 19 ms (Opening)
Mounts OnPlate, Rail
Minimum Operating Temperature-40 Degrees F
Includes Auxiliary ContactsYes
Full Load Current - Inductive25 A
Number of Normally Open Main Contacts2
Resistance PropertiesFire Resistant, Insulation Resistant
Mounting StyleDIN Rail, Plate
Reversing CapabilityNon-Reversing
Terminal Connection TypeScrew Clamp Terminals
Contactor StyleIEC
Overall Width1.77 in
NEMA Enclosure RatingNo Enclosure
Number of Normally Closed Main Contacts2
Electrical Operating Durability1,400,000
Overall Height4.13 in
Frequency50/60 Hz
Maximum Voltage Rating690V AC
Full Load Current - Resistive40 A
Maximum Operating Temperature140 Degrees F
Overall Depth3.9 in
Embedded Surge SuppressorNo
Mechanical Operating Durability15,000,000
Coil Voltage120V AC
NEMA Enclosure MaterialNot Applicable
Number of Auxillary Contacts2
Mounting SupportRail, Plate
Heat Dissipation2 to 3 W at 50/60 Hz
Rated Insulation VoltagePower circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL
Protective TreatmentTHIEC 60068-2-30
Connections - TerminalsControl circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (2.5 to 16 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 16 mm?) - cable stiffness: solid without cable end
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Minimum Switching Current5 mA for signalling circuit
Contact CompatibilityM6
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Poles Description4P
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1, 63 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 40 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Operating Altitude0 to 9842.52 ft (0 to 3000 m)
Control Circuit TypeAC 50/60 Hz
Minimum Switching Voltage17 V for signalling circuit
Pollution Degree3
Average Impedance2 mOhm - Ith 40 A 50 Hz for power circuit
Auxiliary Contact Composition1 NO + 1 NC
Permissible Ambient Air Temperature Around The Device-40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating
Flame RetardanceV1 conforming to UL 94
Conventional Free Air Thermal Current10 A (at 140°F (60°C)) for signalling circuit, 40 A (at 140°F (60°C)) for power circuit
Rated Operational Current40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit
Pole Contact Composition2 NO + 2 NC
Power Dissipation Per Pole3.2 W AC-1
Inrush Power in VA70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Hold-In Power Consumption in VA7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C))
IP Degree Of ProtectionIP20 front face IEC 60529
Rated Short Time Withstand Current240 A 104°F (40°C) - 10 s for power circuit, 380 A 104°F (40°C) - 1 s for power circuit, 50 A 104°F (40°C) - 10 min for power circuit, 120 A 104°F (40°C) - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
IRMS Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 450 A at 440 V for power circuit conforming to IEC 60947
Compatibility CodeLC1D
Product Or Component TypeContactor
Utilisation CategoryAC-1, AC-3, AC-3e, AC-4
Rated Operational VoltagePower circuit Less than or Equal to 690 V AC 25 to 400 Hz
Mechanical RobustnessVibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor closed 15 Gn for 11 ms), Shocks contactor open 8 Gn for 11 ms)
Product CertificationsUL, CSA, CCC, EAC, UKCA, CB, EU-RO-MR by DNV-GL
Control Circuit Voltage120 V AC 50/60 Hz
Rated Impulse Withstand Voltage6 kV IEC 60947
Maximum Operating Rate3600 cyc/h 140°F (60°C)
Protective CoverWith
Fire Resistance1562°F (850°C) IEC 60695-2-1
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Country of Origin (subject to change)Multiple
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#4 Poles
#120 V AC
#25 A
#Reversing: No
#SCHNEIDER ELECTRIC
#Mfr LC1D258G7
#SCHNEIDER ELECTRIC
#GRG0478311
#mfr:LC1D258G7
#part number:LC1D258G7
#pn:LC1D258G7
#part code:LC1D258G7
#item number:LC1D258G7
#product code:LC1D258G7
#manufacturer number:LC1D258G7
#manufacturers part number:LC1D258G7
#mfn:LC1D258G7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!