IEC Magnetic Contactor, 3 Poles, 220 V AC, 18 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D18M7

$164.89

Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 220V AC, Number of Poles 3, Full Load Current - Inductive 18 A, Reversing Capability Non-Reversing, Overall Height 3.03 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC, Horsepower @ Three Phase - 240V AC 5 hp

9999 in stock

Must order in multiples of 1
Subtotal:
$164.89
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC1D18M7
Availability: Ships in 1 days
SKU: GRG0478296 Category:
Full Load Amps-Inductive18 A
ItemIEC Magnetic Contactor
Full Load Amps-Resistive32 A
Number of Poles3
Coil Volts220 V AC
ReversingNo
HP @ 1 Phase - 120V1 hp
Height3.03 in
HP @ 1 Phase - 240V3 hp
Width1.77 in
HP @ 3 Phase - 208V5 hp
HP @ 3 Phase - 575V15 hp
HP @ 3 Phase - 240V5 hp
Depth3.39 in
Enclosure NEMA RatingNo Enclosure
HP @ 3 Phase - 480V10 hp
Aux. Contact Configuration1NO/1NC
Hz50/60
StandardsBV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
Auxiliary Contact Form1NO/1NC
SeriesTeSys Deca
Frame / Series / Class / CodeTeSys
NEMA SizeNot Applicable
Switching Current5 mA (Signalling Circuit)
Signalling Circuit Frequency25 to 400 Hz
Includes Protective CoverYes
Non-Overlap Time1.5 ms
Electrical Durability1.65 Mcycles (18 A, AC-3, Less than 440 V), 1 Mcycles (32 A, AC-1, Less than 440 V), 1.65 Mcycles (18 A, AC-3e, Less than 440 V)
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Switching Voltage17 V (Signalling Circuit)
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 300 A @ 440V (Power Circuit)
ApplicationMotor Control, Resistive Load
Electrical ConnectionScrew Clamp Terminals
Control Circuit Voltage LimitsDrop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Thermal Amperage10 A (at 60°C Signalling Circuit), 32 A (at 60°C Power Circuit)
Working HeightUp to 9842.52 ft
Operating Speed3600 cycles per hr
Rated Breaking Capacity300 A @ 440V
Net Weight0.33 kg
Watts Loss2 to 3W
Fuse Amps10 A (Signalling Circuit), 50 A (Type 1 Power Circuit), 35 A (Type 2 Power Circuit)
Tightening Torque1.7 Nm
Operating Time12 to 22 ms (Closing), 4 to 19 ms (Opening)
IP RatingIP20
Fire RatingUL 94 V1
Rated Voltage690V AC, 300V DC
Inrush VA70 VA
Max. Temperature850°C
Impedance2.5 mOhm
Overvoltage CategoryCAT III
Mechanical Durability15 Mcycles
Shock Resistance15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
FeaturesWithout Built-In Suppressor Module
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Mounts OnPlate, Rail
Rated Insulation Volts600/690V
Max. Operating Watts4 kW (at 220 to 230V AC 50/60 Hz AC-3), 7.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 9 kW (at 415 to 440V AC 50/60 Hz AC-3), 10 kW (at 500V AC 50/60 Hz AC-3), 10 kW (at 660 to 690V AC 50/60 Hz AC-3), 4 kW (at 400V AC 50/60 Hz AC-4), 4 kW (at 220 to 230V AC 50/60 Hz AC-3e), 7.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 9 kW (at 415 to 440V AC 50/60 Hz AC-3e), 10 kW (at 500V AC 50/60 Hz AC-3e), 10 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Impulse Withstand Voltage6 kV
Hold VA7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Rated Short-Time Withstand Current145 A (at 40°C for 10 s Power Circuit), 240 A (at 40°C for 1 s Power Circuit), 40 A (at 40°C for 10 min Power Circuit), 84 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Reversing CapabilityNon-Reversing
Overall Depth3.39 in
Horsepower @ Three Phase - 240V AC5 hp
Horsepower @ Three Phase - 208V AC5 hp
Overall Height3.03 in
Number of Normally Open Main Contacts3
Terminal Connection TypeScrew Clamp Terminals
NEMA Enclosure RatingNo Enclosure
Overall Width1.77 in
Horsepower @ Three Phase - 480V AC10 hp
Frequency50/60 Hz
Resistance PropertiesFire Resistant, Insulation Resistant
Maximum Operating Temperature140 Degrees F
Full Load Current - Inductive18 A
Minimum Operating Temperature-40 Degrees F
Electrical Operating Durability1,000,000, 1,650,000
NEMA Enclosure MaterialNot Applicable
Mounting StyleDIN Rail, Plate
Horsepower @ Single Phase - 240V AC3 hp
Coil Voltage220V AC
Horsepower @ Single Phase - 120V AC1 hp
Horsepower @ Three Phase - 600V AC15 hp
Number of Auxillary Contacts2
Embedded Surge SuppressorNo
Maximum Voltage Rating690V AC
Includes Auxiliary ContactsYes
Mechanical Operating Durability15,000,000
PhaseThree
Contactor StyleIEC
Flame RetardanceV1 conforming to UL 94
Auxiliary Contact Composition1 NO + 1 NC
Poles Description3P
Fire Resistance1562°F (850°C) IEC 60695-2-1
Operating Altitude0 to 9842.52 ft (0 to 3000 m)
Power Dissipation Per Pole2.5 W AC-1, 0.8 W AC-3, 0.8 W AC-3e
Inrush Power in VA70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
IP Degree Of ProtectionIP20 front face IEC 60529
Contactor ApplicationResistive load, Motor control
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Product Or Component TypeContactor
Heat Dissipation2 to 3 W at 50/60 Hz
Mechanical RobustnessVibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor open 10 Gn for 11 ms), Shocks contactor closed 15 Gn for 11 ms)
Average Impedance2.5 mOhm - Ith 32 A 50 Hz for power circuit
Minimum Switching Current5 mA for signalling circuit
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Motor Power KW4 kW at 220 to 230 V AC 50/60 Hz (AC-3), 7.5 kW at 380 to 400 V AC 50/60 Hz (AC-3), 9 kW at 415 to 440 V AC 50/60 Hz (AC-3), 10 kW at 500 V AC 50/60 Hz (AC-3), 10 kW at 660 to 690 V AC 50/60 Hz (AC-3), 4 kW at 400 V AC 50/60 Hz (AC-4), 4 kW at 220 to 230 V AC 50/60 Hz (AC-3e), 7.5 kW at 380 to 400 V AC 50/60 Hz (AC-3e), 9 kW at 415 to 440 V AC 50/60 Hz (AC-3e), 10 kW at 500 V AC 50/60 Hz (AC-3e), 10 kW at 660 to 690 V AC 50/60 Hz (AC-3e)
Contact CompatibilityM2
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1, 50 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 35 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Rated Operational VoltagePower circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC
Rated Impulse Withstand Voltage6 kV IEC 60947
Minimum Switching Voltage17 V for signalling circuit
Protective CoverWith
Connections - TerminalsControl circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1.5 to 6 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 6 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 6 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1.5 to 6 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 6 mm?) - cable stiffness: solid without cable end
Utilisation CategoryAC-1, AC-4, AC-3, AC-3e
Rated Operational Current18 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 32 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 18 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Protective TreatmentTHIEC 60068-2-30
Control Circuit TypeAC 50/60 Hz standard
Rated Insulation VoltagePower circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL
Pole Contact Composition3 NO
Pollution Degree3
Product CertificationsGOST, UL, RINA, CCC, DNV, BV, GL, CSA, LROS (Lloyds register of shipping), UKCA
Control Circuit Voltage220 V AC 50/60 Hz
Mounting SupportPlate, Rail
Permissible Ambient Air Temperature Around The Device-40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating
Compatibility CodeLC1D
Hold-In Power Consumption in VA7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C))
IRMS Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 300 A at 440 V for power circuit conforming to IEC 60947
Maximum Horse Power Rating1 hp at 115 V AC 50/60 Hz for 1 phase motors, 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 5 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 5 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 10 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 15 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Conventional Free Air Thermal Current10 A (at 140°F (60°C)) for signalling circuit, 32 A (at 140°F (60°C)) for power circuit
Rated Short Time Withstand Current145 A 104°F (40°C) - 10 s for power circuit, 240 A 104°F (40°C) - 1 s for power circuit, 40 A 104°F (40°C) - 10 min for power circuit, 84 A 104°F (40°C) - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Maximum Operating Rate3600 cyc/h 140°F (60°C)
Country of Origin (subject to change)Indonesia
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#220 V AC
#18 A
#Reversing: No
#SCHNEIDER ELECTRIC
#Mfr LC1D18M7
#SCHNEIDER ELECTRIC
#GRG0478296
#mfr:LC1D18M7
#part number:LC1D18M7
#pn:LC1D18M7
#part code:LC1D18M7
#item number:LC1D18M7
#product code:LC1D18M7
#manufacturer number:LC1D18M7
#manufacturers part number:LC1D18M7
#mfn:LC1D18M7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!