IEC Magnetic Contactor, 3 Poles, 220 V AC, 65 A, SCHNEIDER ELECTRIC, Mfr# LC1D65AM7

$412,99

Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Number of Poles 3

9999 in stock

Must order in multiples of 1
Subtotal:
$412.99
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC1D65AM7
Availability: Ships in 5 days
SKU: GRG0849698 Category:
Full Load Amps-Inductive65 A
ItemIEC Magnetic Contactor
Full Load Amps-Resistive80 A
Number of Poles3
Coil Volts220 V AC
HP @ 1 Phase - 240V10 hp
Height122 mm
HP @ 3 Phase - 208V20 hp
Width55 mm
HP @ 3 Phase - 240V20 hp
Depth120 mm
HP @ 3 Phase - 575V50 hp
HP @ 3 Phase - 480V40 hp
Aux. Contact Configuration1NO/1NC
SeriesLC1D
IncludesEverlink Power Connections
StandardsCSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1, UL, CCC, GOST, CSA, THIEC 60068-2-30
FeaturesWithout Built-In Suppressor Module
IP RatingIP20
Non-Overlap Time1.5 ms
Operating Speed3600 cycles per hr
Rated Insulation Volts600/690V
Impedance1.5 mOhm
Mounts OnPlate, Rail
Rated Voltage690V AC, 300V DC
Watts Loss4 to 5W
Switching Voltage17 V (Signalling Circuit)
Includes Protective CoverYes
Tightening Torque1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit)
Thermal Amperage10 A (at 60°C Signalling Circuit), 80 A (at 60°C Power Circuit)
Impulse Withstand Voltage6 kV
Fire RatingUL 94 V1
Switching Current5 mA (Signalling Circuit)
Hold VA13 VA (at 60 Hz 20°C), 15 VA (at 50 Hz 20°C)
Rated Short-Time Withstand Current520 A (at 40°C for 10 s Power Circuit), 900 A (at 40°C for 1 s Power Circuit), 110 A (at 40°C for 10 min Power Circuit), 260 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Signalling Circuit Frequency25 to 400 Hz
Fuse Amps10 A (Signalling Circuit), 125 A (Type 1 Power Circuit), 125 A (Type 2 Power Circuit)
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1000 A @ 440V (Power Circuit)
ApplicationMotor Control, Resistive Load
Rated Breaking Capacity1000 A @ 440V
Inrush VA140 VA (at 60 Hz 20°C), 160 VA (at 50 Hz 20°C)
Net Weight0.86 kg
Max. Temperature850°C
Mechanical Durability6 Mcycles
Max. Operating Watts11 kW (at 400V AC 50/60 Hz AC-4), 18.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 30 kW (at 380 to 400V AC 50/60 Hz AC-3), 37 kW (at 500V AC 50/60 Hz AC-3), 37 kW (at 660 to 690V AC 50/60 Hz AC-3), 18.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 30 kW (at 380 to 400V AC 50/60 Hz AC-3e), 37 kW (at 500V AC 50/60 Hz AC-3e), 37 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Control Circuit Voltage LimitsDrop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Working HeightUp to 9842.52 ft
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Shock Resistance10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Electrical ConnectionControl Circuit: Screw Clamp Terminals, Power Circuit: EverLink BTR Screw Connectors
Operating Time4 to 19 ms (Opening), 12 to 26 ms (Closing)
Electrical Durability1.4 Mcycles (80 A, AC-1, Less than 440 V), 1.45 Mcycles (65 A, AC-3, Less than 440 V), 1.45 Mcycles (65 A, AC-3e, Less than 440 V)
Overvoltage CategoryCAT III
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Rated Operational Current80 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 65 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 65 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Protective CoverWith
Contact CompatibilityM2
Inrush Power in VA140 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 160 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Mounting SupportRail, Plate
Contactor ApplicationMotor control, Resistive load
Flame RetardanceV1 conforming to UL 94
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1, 125 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 125 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Conventional Free Air Thermal Current10 A (at 140°F (60°C)) for signalling circuit, 80 A (at 140°F (60°C)) for power circuit
Poles Description3P
Connections - TerminalsControl circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: EverLink BTR screw connectors 1 0.00 to 0.05 in? (1 to 35 mm?) - cable stiffness: flexible without cable end, Power circuit: EverLink BTR screw connectors 2 0.00 to 0.04 in? (1 to 25 mm?) - cable stiffness: flexible without cable end, Power circuit: EverLink BTR screw connectors 1 0.00 to 0.05 in? (1 to 35 mm?) - cable stiffness: flexible with cable end, Power circuit: EverLink BTR screw connectors 2 0.00 to 0.04 in? (1 to 25 mm?) - cable stiffness: flexible with cable end, Power circuit: EverLink BTR screw connectors 1 0.00 to 0.05 in? (1 to 35 mm?) - cable stiffness: solid without cable end, Power circuit: EverLink BTR screw connectors 2 0.00 to 0.04 in? (1 to 25 mm?) - cable stiffness: solid without cable end
Power Dissipation Per Pole9.6 W AC-1, 6.3 W AC-3, 6.3 W AC-3e
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Rated Insulation VoltagePower circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL, Power circuit 690 V IEC 60947-4-1
Operating Altitude0 to 9842.52 ft (0 to 3000 m)
Minimum Switching Voltage17 V for signalling circuit
Hold-In Power Consumption in VA13 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 15 VA 50 Hz cos phi 0.3 (at 68°F (20°C))
IRMS Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 1000 A at 440 V for power circuit conforming to IEC 60947
Product CertificationsUL, CCC, GOST, CSA
Permissible Ambient Air Temperature Around The Device-40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating
Rated Impulse Withstand Voltage6 kV IEC 60947
Minimum Switching Current5 mA for signalling circuit
Protective TreatmentTHIEC 60068-2-30
Control Circuit Voltage220 V AC 50/60 Hz
Fire Resistance1562°F (850°C) IEC 60695-2-1
Product Or Component TypeContactor
Maximum Operating Rate3600 cyc/h 140°F (60°C)
Pollution Degree3
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Motor Power KW11 kW at 400 V AC 50/60 Hz (AC-4), 18.5 kW at 220 to 230 V AC 50/60 Hz (AC-3), 30 kW at 380 to 400 V AC 50/60 Hz (AC-3), 37 kW at 500 V AC 50/60 Hz (AC-3), 37 kW at 660 to 690 V AC 50/60 Hz (AC-3), 18.5 kW at 220 to 230 V AC 50/60 Hz (AC-3e), 30 kW at 380 to 400 V AC 50/60 Hz (AC-3e), 37 kW at 500 V AC 50/60 Hz (AC-3e), 37 kW at 660 to 690 V AC 50/60 Hz (AC-3e)
Rated Operational VoltagePower circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC
Auxiliary Contact Composition1 NO + 1 NC
IP Degree Of ProtectionIP20 front face IEC 60529
Heat Dissipation4 to 5 W at 50/60 Hz
Rated Short Time Withstand Current640 A 104°F (40°C) - 10 s for power circuit, 900 A 104°F (40°C) - 1 s for power circuit, 110 A 104°F (40°C) - 10 min for power circuit, 260 A 104°F (40°C) - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Mechanical RobustnessVibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor closed 15 Gn for 11 ms), Shocks contactor open 10 Gn for 11 ms)
Pole Contact Composition3 NO
Average Impedance1.5 mOhm - Ith 80 A 50 Hz for power circuit
Control Circuit TypeAC 50/60 Hz standard
Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
Utilisation CategoryAC-4, AC-1, AC-3, AC-3e
Maximum Horse Power Rating40 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 5 hp at 115 V AC 50/60 Hz for 1 phase motors, 10 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 20 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 20 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 50 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Country of Origin (subject to change)Multiple
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#220 V AC
#65 A
#SCHNEIDER ELECTRIC
#Mfr LC1D65AM7
#SCHNEIDER ELECTRIC
#GRG0849698
#mfr:LC1D65AM7
#part number:LC1D65AM7
#pn:LC1D65AM7
#part code:LC1D65AM7
#item number:LC1D65AM7
#product code:LC1D65AM7
#manufacturer number:LC1D65AM7
#manufacturers part number:LC1D65AM7
#mfn:LC1D65AM7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!