Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 18 A |
Full Load Amps-Resistive | 32 A |
Number of Poles | 3 |
Coil Volts | 24 V DC |
Reversing | No |
HP @ 1 Phase - 120V | 1 hp |
Height | 3.03 in |
HP @ 1 Phase - 240V | 3 hp |
HP @ 3 Phase - 208V | 5 hp |
Width | 1.77 in |
HP @ 3 Phase - 575V | 15 hp |
HP @ 3 Phase - 240V | 5 hp |
Depth | 3.74 in |
Enclosure NEMA Rating | No Enclosure |
HP @ 3 Phase - 480V | 10 hp |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Frame / Series / Class / Code | TeSys |
Auxiliary Contact Form | 1NO/1NC |
Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
Series | TeSys Deca |
NEMA Size | Not Applicable |
Includes Protective Cover | Yes |
Switching Current | 5 mA (Signalling Circuit) |
Net Weight | 0.49 kg |
Signalling Circuit Frequency | 25 to 400 Hz |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 300 A @ 440V (Power Circuit) |
Rated Breaking Capacity | 300 A @ 440V |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
Electrical Connection | Screw Clamp Terminals |
Tightening Torque | 1.7 Nm |
Operating Speed | 3600 cycles per hr |
Control Circuit Voltage Limits | Drop-Out DC: 0.1 to 0.3 Uc (at -40 to 70°C), Operational DC: 0.8 to 1.25 Uc (at -40 to 60°C), 1 to 1.25 Uc (at 60 to 70°C) |
Working Height | Up to 9842.52 ft |
Features | Built-In Bi-Directional Peak Limiting Diode Suppressor |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 32 A (at 60°C Power Circuit) |
Rated Voltage | 690V AC, 300V DC |
Rated Short-Time Withstand Current | 145 A (at 40°C for 10 s Power Circuit), 240 A (at 40°C for 1 s Power Circuit), 40 A (at 40°C for 10 min Power Circuit), 84 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Fire Rating | UL 94 V1 |
IP Rating | IP20 |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Application | Motor Control, Resistive Load |
Max. Operating Watts | 4 kW (at 220 to 230V AC 50/60 Hz AC-3), 7.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 9 kW (at 415 to 440V AC 50/60 Hz AC-3), 10 kW (at 500V AC 50/60 Hz AC-3), 10 kW (at 660 to 690V AC 50/60 Hz AC-3), 4 kW (at 400V AC 50/60 Hz AC-4), 4 kW (at 220 to 230V AC 50/60 Hz AC-3e), 7.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 9 kW (at 415 to 440V AC 50/60 Hz AC-3e), 10 kW (at 500V AC 50/60 Hz AC-3e), 10 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
Fuse Amps | 10 A (Signalling Circuit), 50 A (Type 1 Power Circuit), 35 A (Type 2 Power Circuit) |
Mounts On | Plate, Rail |
Electrical Durability | 1.65 Mcycles (18 A, AC-3, Less than 440 V), 1 Mcycles (32 A, AC-1, Less than 440 V), 1.65 Mcycles (18 A, AC-3e, Less than 440 V) |
Max. Temperature | 850°C |
Operating Time | 65.45 to 88.55 ms (Closing), 20 to 30 ms (Opening) |
Overvoltage Category | CAT III |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Impulse Withstand Voltage | 6 kV |
Rated Insulation Volts | 600/690V |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Switching Voltage | 17 V (Signalling Circuit) |
Mechanical Durability | 30 Mcycles |
Impedance | 2.5 mOhm |
Non-Overlap Time | 1.5 ms |
Horsepower @ Three Phase - 240V AC | 5 hp |
Mechanical Operating Durability | 30,000,000 |
Overall Depth | 3.74 in |
Horsepower @ Three Phase - 208V AC | 5 hp |
Overall Width | 1.77 in |
Overall Height | 3.03 in |
Maximum Operating Temperature | 140 Degrees F |
Number of Normally Open Main Contacts | 3 |
Contactor Style | IEC |
Horsepower @ Single Phase - 120V AC | 1 hp |
Horsepower @ Three Phase - 600V AC | 15 hp |
Full Load Current - Inductive | 18 A |
Frequency | 50/60 Hz |
Electrical Operating Durability | 1,000,000, 1,650,000 |
Mounting Style | DIN Rail, Plate |
Includes Auxiliary Contacts | Yes |
Horsepower @ Three Phase - 480V AC | 10 hp |
Number of Auxillary Contacts | 2 |
Embedded Surge Suppressor | Yes |
NEMA Enclosure Material | Not Applicable |
Minimum Operating Temperature | -40 Degrees F |
Phase | Three |
NEMA Enclosure Rating | No Enclosure |
Resistance Properties | Fire Resistant, Insulation Resistant |
Horsepower @ Single Phase - 240V AC | 3 hp |
Coil Voltage | 24V DC |
Maximum Voltage Rating | 690V AC |
Reversing Capability | Non-Reversing |
Terminal Connection Type | Screw Clamp Terminals |
Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
IRMS Rated Making Capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 300 A at 440 V for power circuit conforming to IEC 60947 |
Protective Treatment | THIEC 60068-2-30 |
Average Impedance | 2.5 mOhm - Ith 32 A 50 Hz for power circuit |
Operating Altitude | 0 to 9842.52 ft (0 to 3000 m) |
Contactor Application | Motor control, Resistive load |
Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC |
Time Constant | 40 ms |
Rated Insulation Voltage | Power circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL |
Maximum Horse Power Rating | 1 hp at 115 V AC 50/60 Hz for 1 phase motors, 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 5 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 5 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 10 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 15 hp at 575/600 V AC 50/60 Hz for 3 phase motors |
Poles Description | 3P |
Pole Contact Composition | 3 NO |
Protective Cover | With |
Minimum Switching Voltage | 17 V for signalling circuit |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Maximum Operating Rate | 3600 cyc/h 140°F (60°C) |
Permissible Ambient Air Temperature Around The Device | -40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1, 50 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 35 A gG at Less than or Equal to 690 V coordination type 2 for power circuit |
IP Degree Of Protection | IP20 front face IEC 60529 |
Pollution Degree | 3 |
Auxiliary Contact Composition | 1 NO + 1 NC |
Conventional Free Air Thermal Current | 10 A (at 140°F (60°C)) for signalling circuit, 32 A (at 140°F (60°C)) for power circuit |
Rated Operational Current | 18 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 32 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 18 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit |
Compatibility Code | LC1D |
Contact Compatibility | M5 |
Motor Power KW | 4 kW at 220 to 230 V AC 50/60 Hz (AC-3), 7.5 kW at 380 to 400 V AC 50/60 Hz (AC-3), 9 kW at 415 to 440 V AC 50/60 Hz (AC-3), 10 kW at 500 V AC 50/60 Hz (AC-3), 10 kW at 660 to 690 V AC 50/60 Hz (AC-3), 4 kW at 400 V AC 50/60 Hz (AC-4), 4 kW at 220 to 230 V AC 50/60 Hz (AC-3e), 7.5 kW at 380 to 400 V AC 50/60 Hz (AC-3e), 9 kW at 415 to 440 V AC 50/60 Hz (AC-3e), 10 kW at 500 V AC 50/60 Hz (AC-3e), 10 kW at 660 to 690 V AC 50/60 Hz (AC-3e) |
Mechanical Robustness | Vibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor open 10 Gn for 11 ms), Shocks contactor closed 15 Gn for 11 ms) |
Inrush Power in W | 2.4 W 68°F (20°C)) |
Flame Retardance | V1 conforming to UL 94 |
Coil Technology | Built-in bidirectional peak limiting diode suppressor |
Utilisation Category | AC-1, AC-3, AC-4, AC-3e |
Product Certifications | BV, GOST, CCC, DNV, LROS (Lloyds register of shipping), UL, GL, CSA, RINA, UKCA |
Rated Short Time Withstand Current | 145 A 104°F (40°C) - 10 s for power circuit, 240 A 104°F (40°C) - 1 s for power circuit, 40 A 104°F (40°C) - 10 min for power circuit, 84 A 104°F (40°C) - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit |
Product Or Component Type | Contactor |
Power Dissipation Per Pole | 2.5 W AC-1, 0.8 W AC-3, 0.8 W AC-3e |
Control Circuit Type | DC low consumption |
Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1 |
Connections - Terminals | Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1.5 to 6 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 6 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 6 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1.5 to 6 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 6 mm?) - cable stiffness: solid without cable end |
Mounting Support | Plate, Rail |
Climatic Withstand | IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat |
Minimum Switching Current | 5 mA for signalling circuit |
Hold-In Power Consumption in W | 2.4 W 68°F (20°C) |
Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
Country of Origin (subject to change) | Multiple |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 24 V DC, 18 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D18BL
$204.66
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V DC, Number of Poles 3, Full Load Current - Inductive 18 A, Reversing Capability Non-Reversing, Overall Height 3.03 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC, Horsepower @ Three Phase - 240V AC 5 hp
9999 in stock
Must order in multiples of 1
Subtotal:
$204.66
You must be logged in to post a review.
Reviews
There are no reviews yet.