IEC Magnetic Contactor, 3 Poles, 24 V AC, 40 A, SCHNEIDER ELECTRIC, Mfr# LC1D40A6B7

$272,99

Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Number of Poles 3

9999 in stock

Must order in multiples of 1
Subtotal:
$272.99
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC1D40A6B7
Availability: Ships in 5 days
SKU: GRG0849619 Category:

Analogues

Full Load Amps-Inductive40 A
ItemIEC Magnetic Contactor
Full Load Amps-Resistive60 A
Number of Poles3
Coil Volts24 V AC
HP @ 1 Phase - 240V5 hp
Height122 mm
HP @ 3 Phase - 208V10 hp
Width55 mm
HP @ 3 Phase - 575V30 hp
Depth120 mm
HP @ 3 Phase - 240V10 hp
HP @ 3 Phase - 480V30 hp
Aux. Contact Configuration1NO/1NC
SeriesLC1D
IncludesEverlink Power Connections
StandardsCSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1, CSA, GOST, UL, CCC, THIEC 60068-2-30
ApplicationMotor Control, Resistive Load
FeaturesWithout Built-In Suppressor Module
Switching Current5 mA (Signalling Circuit)
Switching Voltage17 V (Signalling Circuit)
Shock Resistance10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Watts Loss4 to 5W
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Operating Speed3600 cycles per hr
Tightening Torque1.7 Nm (Control Circuit), 2.5 to 6 Nm (Power Circuit)
Mechanical Durability6 Mcycles
Max. Temperature850°C
Non-Overlap Time1.5 ms
Rated Short-Time Withstand Current320 A (at 40°C for 10 s Power Circuit), 720 A (at 40°C for 1 s Power Circuit), 72 A (at 40°C for 10 min Power Circuit), 165 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Rated Insulation Volts600/690V
Electrical ConnectionLugs-Ring Terminals
Hold VA13 VA (at 60 Hz 20°C), 15 VA (at 50 Hz 20°C)
Includes Protective CoverYes
Inrush VA140 VA (at 60 Hz 20°C), 160 VA (at 50 Hz 20°C)
Operating Time4 to 19 ms (Opening), 12 to 26 ms (Closing)
Overvoltage CategoryCAT III
Thermal Amperage10 A (at 60°C Signalling Circuit), 60 A (at 60°C Power Circuit)
Max. Operating Watts18.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 11 kW (at 220 to 230V AC 50/60 Hz AC-3), 22 kW (at 415 to 440V AC 50/60 Hz AC-3), 22 kW (at 500V AC 50/60 Hz AC-3), 30 kW (at 660 to 690V AC 50/60 Hz AC-3), 9 kW (at 400V AC 50/60 Hz AC-4), 18.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 11 kW (at 220 to 230V AC 50/60 Hz AC-3e), 22 kW (at 415 to 440V AC 50/60 Hz AC-3e), 22 kW (at 500V AC 50/60 Hz AC-3e), 30 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Fuse Amps10 A (Signalling Circuit), 80 A (Type 1 Power Circuit), 80 A (Type 2 Power Circuit)
Mounts OnPlate, Rail
Working HeightUp to 9842.52 ft
Impulse Withstand Voltage6 kV
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 800 A @ 440V (Power Circuit)
Fire RatingUL 94 V1
Impedance1.5 mOhm
Control Circuit Voltage LimitsDrop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Rated Breaking Capacity800 A @ 440V
Net Weight0.85 kg
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Electrical Durability1.4 Mcycles (60 A, AC-1, Less than 440 V), 1.5 Mcycles (40 A, AC-3, Less than 440 V), 1.5 Mcycles (40 A, AC-3e, Less than 440 V)
Signalling Circuit Frequency25 to 400 Hz
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Rated Voltage690V AC, 300V DC
IP RatingIP20
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#24 V AC
#40 A
#SCHNEIDER ELECTRIC
#Mfr LC1D40A6B7
#SCHNEIDER ELECTRIC
#GRG0849619
#mfr:LC1D40A6B7
#part number:LC1D40A6B7
#pn:LC1D40A6B7
#part code:LC1D40A6B7
#item number:LC1D40A6B7
#product code:LC1D40A6B7
#manufacturer number:LC1D40A6B7
#manufacturers part number:LC1D40A6B7
#mfn:LC1D40A6B7

Reviews

There are no reviews yet.

Add a review