Item
IEC Magnetic Contactor
Full Load Amps-Inductive
65 A
Full Load Amps-Resistive
80 A
Aux. Contact Configuration
1NO/1NC
Standards
CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1, UL, CSA, RINA, GOST, CCC, DNV, LROS, GL, BV, UKCA, TH IEC 60068-2-30
Features
Built-In Bi-Directional Peak Limiting Diode Suppressor; Preassembled with Reversing Power Busbar
Application
Motor Control, Resistive Load
Operating Time
16 to 24 ms (Opening), 42.5 to 57.5 ms (Closing)
Overvoltage Category
CAT III
Working Height
Up to 9842.52 ft
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Electrical Durability
1.45 Mcycles (65 A, AC-3, Less than 440 V); 1.4 Mcycles (80 A, AC-1, Less than 440 V)
Switching Current
5 mA (Signalling Circuit)
Rated Short-Time Withstand Current
520 A (at 40°C for 10 s Power Circuit), 900 A (at 40°C for 1 s Power Circuit), 110 A (at 40°C for 10 min Power Circuit), 260 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Control Circuit Voltage Limits
Drop-Out DC: 0.1 to 0.3 Uc (at -40 to 70°C); Operational DC: 0.75 to 1.25 Uc (at -40 to 60°C), 1 to 1.25 Uc (at 60 to 70°C)
Shock Resistance
15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Rated Voltage
690V AC, 300V DC
Thermal Amperage
10 A (at 60°C Signalling Circuit), 80 A (at 60°C Power Circuit)
Electrical Connection
Control Circuit: Screw Clamp Terminals, Power Circuit: EverLink BTR Screw Connectors
Includes Protective Cover
Yes
Rated Insulation Volts
600/690V
Rated Making Capacity
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1000 A @ 440V (Power Circuit)
Operating Speed
3600 cycles per hr
Fuse Amps
10 A (Signalling Circuit), 125 A (Type 1 Power Circuit), 125 A (Type 2 Power Circuit)
Switching Voltage
17 V (Signalling Circuit)
Signalling Circuit Frequency
25 to 400 Hz
Mechanical Durability
10 Mcycles
Tightening Torque
1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit)
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Environmental Attributes
Mercury Free, PVC Free, Pollution Degree 3
Max. Operating Watts
18.5 kW (at 220 to 230V AC 50 Hz), 30 kW (at 380 to 400V AC 50 Hz), 37 kW (at 415 to 440V AC 50 Hz), 37 kW (at 500V AC 50 Hz), 37 kW (at 660 to 690V AC 50 Hz)
Impulse Withstand Voltage
6 kV
Rated Breaking Capacity
1000 A @ 440V
[Ue] Rated Operational Voltage
power circuit u003c= 690 V AC 25...400 Hz, power circuit u003c= 300 V DC
Pole Contact Composition
3 NO
Ip Degree of Protection
IP20 front face IEC 60529
Ambient Air Temperature For Operation
-40-60°C, 60-70°C with derating
Auxiliary Contacts Type
mechanically linked 1 NO + 1 NC IEC 60947-5-1, mirror contact 1 NC IEC 60947-4-1
Protective Treatment
TH IEC 60068-2-30
[Ui] Rated Insulation Voltage
power circuit 690 V IEC 60947-4-1, power circuit 600 V CSA, power circuit 600 V UL, signalling circuit 690 V IEC 60947-1, signalling circuit 600 V CSA, signalling circuit 600 V UL
Power Dissipation Per Pole
9.6 W AC-1, 6.3 W AC-3, 6.3 W AC-3e
Product or Component Type
reversing contactor
Control Circuit Type
DC standard
Maximum Horse Power Rating
40 hp at 460/480 V AC 60 Hz for 3 phase motors, 5 hp at 115 V AC 60 Hz for 1 phase motors, 10 hp at 230/240 V AC 60 Hz for 1 phase motors, 20 hp at 200/208 V AC 60 Hz for 3 phase motors, 20 hp at 230/240 V AC 60 Hz for 3 phase motors, 50 hp at 575/600 V AC 60 Hz for 3 phase motors
[Ith] Conventional Free Air Thermal Current
10 A (at 60°C) for signalling circuit, 80 A (at 60°C) for power circuit
Irms Rated Making Capacity
140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 1000 A at 440 V for power circuit conforming to IEC 60947
Coil Technology
built-in bidirectional peak limiting diode suppressor
[Icw] Rated Short-Time Withstand Current
520 A 40°C - 10 s for power circuit, 900 A 40°C - 1 s for power circuit, 110 A 40°C - 10 min for power circuit, 260 A 40°C - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Insulation Resistance
u003e 10 MOhm for signalling circuit
Minimum Switching Current
5 mA for signalling circuit
Minimum Switching Voltage
17 V for signalling circuit
Mechanical Robustness
vibrations contactor open2 Gn, 5...300 Hz, vibrations contactor closed4 Gn, 5...300 Hz, shocks contactor open10 Gn for 11 ms, shocks contactor closed15 Gn for 11 ms
Associated Fuse Rating
10 A gG for signalling circuit conforming to IEC 60947-5-1, 125 A gG at u003c= 690 V coordination type 1 for power circuit, 125 A gG at u003c= 690 V coordination type 2 for power circuit
Interlocking Type
mechanical
Inrush Power In W
19-19 W 20°C)
Connections - Terminals
control circuit screw clamp terminals 1 1-4 mm²flexible without cable end, control circuit screw clamp terminals 2 1-4 mm²flexible without cable end, control circuit screw clamp terminals 1 1-4 mm²flexible with cable end, control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end, control circuit screw clamp terminals 1 1-4 mm²solid, control circuit screw clamp terminals 2 1-4 mm²solid, power circuit EverLink BTR screw connectors 1 1-35 mm²flexible without cable end, power circuit EverLink BTR screw connectors 2 1-25 mm²flexible without cable end, power circuit EverLink BTR screw connectors 1 1-35 mm²flexible with cable end, power circuit EverLink BTR screw connectors 2 1-25 mm²flexible with cable end, power circuit EverLink BTR screw connectors 1 1-35 mm²solid, power circuit EverLink BTR screw connectors 2 1-25 mm²solid
[Ie] Rated Operational Current
80 A (at u003c60°C) at u003c= 440 V AC AC-1 for power circuit, 65 A (at u003c60°C) at u003c= 440 V AC AC-3 for power circuit, 65 A (at u003c60°C) at u003c= 440 V AC AC-3e for power circuit
Flame Retardance
V1 conforming to UL 94
Maximum Operating Rate
3600 cyc/h 60°C
Contactor Application
resistive load, motor control
Device Presentation
preassembled with reversing power busbar
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60947
Utilisation Category
AC-3, AC-1, AC-3e
Ambient Air Temperature For Storage
-60-80°C
Operating Altitude
0...9842.52 ft (0...3000 m)
Climatic Withstand
IACS E10, IEC 60947-1 Annex Q category D
Motor Power Kw
18.5 kW at 220...230 V AC 50 Hz, 30 kW at 380...400 V AC 50 Hz, 37 kW at 415...440 V AC 50 Hz, 37 kW at 500 V AC 50 Hz, 37 kW at 660...690 V AC 50 Hz
Auxiliary Contact Composition
1 NO + 1 NC
Hold-In Power Consumption In W
7.4-7.4 W 20°C
Mounting Support
rail, plate
Fire Resistance
850°C IEC 60695-2-1
Average Impedance
1.5 mOhm - Ith 80 A 50 Hz for power circuit
Country of Origin (subject to change)
France