Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 65 A |
Full Load Amps-Resistive | 80 A |
Action | Non-Reversing |
Number of Poles | 3 |
Coil Volts | 24 V DC |
Reversing | No |
HP @ 1 Phase - 120V | 5 hp |
HP @ 1 Phase - 230V | 10 |
HP @ 1 Phase - 240V | 10 hp |
Height | 4.8 in |
Width | 2.17 in |
HP @ 3 Phase - 208V | 20 hp |
HP @ 3 Phase - 575V | 50 hp |
HP @ 3 Phase - 240V | 20 hp |
Depth | 4.72 in |
HP @ 3 Phase - 480V | 40 hp |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Standards | CCC, CSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, UL Listed |
Auxiliary Contact Form | 1NO/1NC |
Includes | Everlink Power Connections |
NEMA Size | Not Applicable |
Series | TeSys Deca |
Features | Built-In Bi-Directional Peak Limiting Diode Suppressor |
Control Circuit Voltage Limits | Drop-Out DC: 0.1 to 0.3 Uc (at -40 to 70°C), Operational DC: 0.75 to 1.25 Uc (at -40 to 60°C), 1 to 1.25 Uc (at 60 to 70°C) |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 80 A (at 60°C Power Circuit) |
Application | Motor Control, Resistive Load |
Operating Time | 42.5 to 57.5 ms (Closing), 16 to 24 ms (Opening) |
Impulse Withstand Voltage | 6 kV |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1000 A @ 440V (Power Circuit) |
Electrical Connection | Screw Clamp Terminals |
Net Weight | 0.935 kg |
Includes Protective Cover | Yes |
Non-Overlap Time | 1.5 ms |
Environmental Attributes | Mercury Free, PVC Free, Pollution Degree 3 |
Overvoltage Category | CAT III |
Signalling Circuit Frequency | 25 to 400 Hz |
Electrical Durability | 0.5 Mcycles (80 A, AC-1, Less than 440 V), 1.45 Mcycles (65 A, AC-3, Less than 440 V), 1.45 Mcycles (65 A, AC-3e, Less than 440 V) |
Fuse Amps | 10 A (Signalling Circuit), 125 A (Type 1 Power Circuit), 125 A (Type 2 Power Circuit) |
Operating Speed | 3600 cycles per hr |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Rated Short-Time Withstand Current | 520 A (at 40°C for 10 s Power Circuit), 900 A (at 40°C for 1 s Power Circuit), 110 A (at 40°C for 10 min Power Circuit), 260 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Rated Breaking Capacity | 1000 A @ 440V |
Rated Insulation Volts | 600/690V |
IP Rating | IP20 |
Tightening Torque | 1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit) |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Switching Current | 5 mA (Signalling Circuit) |
Working Height | Up to 9842.52 ft |
Rated Voltage | 690V AC, 300V DC |
Switching Voltage | 17 V (Signalling Circuit) |
Fire Rating | UL 94 V1 |
Shock Resistance | 10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed) |
Mounts On | Plate, Rail |
Mechanical Durability | 10 Mcycles |
Impedance | 1.5 mOhm |
Max. Operating Watts | 11 kW (at 400V AC 50/60 Hz AC-4), 18.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 30 kW (at 380 to 400V AC 50/60 Hz AC-3), 37 kW (at 500V AC 50/60 Hz AC-3), 37 kW (at 660 to 690V AC 50/60 Hz AC-3), 18.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 30 kW (at 380 to 400V AC 50/60 Hz AC-3e), 37 kW (at 500V AC 50/60 Hz AC-3e), 37 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
Max. Temperature | 850°C |
Number of Normally Open Main Contacts | 3 |
Horsepower @ Single Phase - 120V AC | 5 hp |
Reversing Capability | Non-Reversing |
Resistance Properties | Fire Resistant, Insulation Resistant |
Full Load Current - Inductive | 65 A |
Includes Auxiliary Contacts | Yes |
Mounting Style | DIN Rail, Plate |
Overall Depth | 4.72 in |
Horsepower @ Three Phase - 600V AC | 50 hp |
Horsepower @ Three Phase - 480V AC | 40 hp |
NEMA Enclosure Rating | No Enclosure |
Horsepower @ Three Phase - 240V AC | 20 hp |
Overall Width | 2.17 in |
Horsepower @ Three Phase - 208V AC | 20 hp |
Coil Voltage | 24V DC |
Electrical Operating Durability | 1,450,000, 500,000 |
Maximum Operating Temperature | 140 Degrees F |
Frequency | 50/60 Hz |
Terminal Connection Type | Screw Clamp Terminals |
Contactor Style | IEC |
Maximum Voltage Rating | 690V AC |
Overall Height | 4.8 in |
Number of Auxillary Contacts | 2 |
Mechanical Operating Durability | 10,000,000 |
Minimum Operating Temperature | -40 Degrees F |
Full Load Current - Resistive | 80 A |
Phase | Three |
NEMA Enclosure Material | Not Applicable |
Horsepower @ Single Phase - 240V AC | 10 hp |
Embedded Surge Suppressor | Yes |
Rated Short Time Withstand Current | 640 A 104°F (40°C) - 10 s for power circuit, 900 A 104°F (40°C) - 1 s for power circuit, 110 A 104°F (40°C) - 10 min for power circuit, 260 A 104°F (40°C) - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit |
Flame Retardance | V1 conforming to UL 94 |
Climatic Withstand | IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat |
Motor Power KW | 11 kW at 400 V AC 50/60 Hz (AC-4), 18.5 kW at 220 to 230 V AC 50/60 Hz (AC-3), 30 kW at 380 to 400 V AC 50/60 Hz (AC-3), 37 kW at 500 V AC 50/60 Hz (AC-3), 37 kW at 660 to 690 V AC 50/60 Hz (AC-3), 18.5 kW at 220 to 230 V AC 50/60 Hz (AC-3e), 30 kW at 380 to 400 V AC 50/60 Hz (AC-3e), 37 kW at 500 V AC 50/60 Hz (AC-3e), 37 kW at 660 to 690 V AC 50/60 Hz (AC-3e) |
Rated Insulation Voltage | Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL, Power circuit 690 V IEC 60947-4-1 |
Maximum Horse Power Rating | 40 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 5 hp at 115 V AC 50/60 Hz for 1 phase motors, 10 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 20 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 20 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 50 hp at 575/600 V AC 50/60 Hz for 3 phase motors |
IRMS Rated Making Capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 1000 A at 440 V for power circuit conforming to IEC 60947 |
Maximum Operating Rate | 3600 cyc/h 140°F (60°C) |
Protective Treatment | THIEC 60068-2-30 |
Minimum Switching Current | 5 mA for signalling circuit |
Hold-In Power Consumption in W | 7.4 W 68°F (20°C) |
Pollution Degree | 3 |
Time Constant | 34 ms |
Coil Technology | Built-in bidirectional peak limiting diode suppressor |
Conventional Free Air Thermal Current | 10 A (at 140°F (60°C)) for signalling circuit, 80 A (at 140°F (60°C)) for power circuit |
Product Or Component Type | Contactor |
Operating Altitude | 0 to 9842.52 ft (0 to 3000 m) |
Mounting Support | Plate, Rail |
Power Dissipation Per Pole | 9.6 W AC-1, 6.3 W AC-3, 6.3 W AC-3e |
Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1 |
IP Degree Of Protection | IP20 front face IEC 60529 |
Contactor Application | Motor control, Resistive load |
Protective Cover | With |
Rated Operational Current | 80 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 65 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 65 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit |
Auxiliary Contact Composition | 1 NO + 1 NC |
Contact Compatibility | M4 |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
Product Certifications | GOST, UL, CCC, CSA |
Poles Description | 3P |
Mechanical Robustness | Vibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor closed 15 Gn for 11 ms), Shocks contactor open 10 Gn for 11 ms) |
Utilisation Category | AC-4, AC-1, AC-3, AC-3e |
Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
Pole Contact Composition | 3 NO |
Minimum Switching Voltage | 17 V for signalling circuit |
Permissible Ambient Air Temperature Around The Device | -40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating |
Connections - Terminals | Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: screw connection 1 0.00 to 0.05 in? (1 to 35 mm?) - cable stiffness: flexible without cable end, Power circuit: screw connection 2 0.00 to 0.04 in? (1 to 25 mm?) - cable stiffness: flexible without cable end, Power circuit: screw connection 1 0.00 to 0.05 in? (1 to 35 mm?) - cable stiffness: flexible with cable end, Power circuit: screw connection 2 0.00 to 0.04 in? (1 to 25 mm?) - cable stiffness: flexible with cable end, Power circuit: screw connection 1 0.00 to 0.05 in? (1 to 35 mm?) - cable stiffness: solid without cable end, Power circuit: screw connection 2 0.00 to 0.04 in? (1 to 25 mm?) - cable stiffness: solid without cable end |
Control Circuit Type | DC standard |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Average Impedance | 1.5 mOhm - Ith 80 A 50 Hz for power circuit |
Compatibility Code | LC1D |
Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC |
Inrush Power in W | 19 W 68°F (20°C)) |
Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1, 125 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 125 A gG at Less than or Equal to 690 V coordination type 2 for power circuit |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 24 V DC, 65 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D65ABD
$405.45
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V DC, Number of Poles 3, Full Load Current - Inductive 65 A, Full Load Current - Resistive 80 A, Reversing Capability Non-Reversing, Overall Height 4.8 in, Overall Width 2.17 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$405.45
You must be logged in to post a review.
Reviews
There are no reviews yet.