Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 18 A |
Full Load Amps-Resistive | 32 A |
Number of Poles | 3 |
Coil Volts | 24 to 60 V AC/DC |
Reversing | Yes |
HP @ 1 Phase - 120V | 1 hp |
Height | 3.03 in |
HP @ 1 Phase - 240V | 3 hp |
HP @ 3 Phase - 208V | 5 hp |
Width | 3.54 in |
HP @ 3 Phase - 240V | 5 hp |
HP @ 3 Phase - 575V | 15 hp |
Depth | 3.38 in |
Enclosure NEMA Rating | No Enclosure |
HP @ 3 Phase - 480V | 10 hp |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Frame / Series / Class / Code | TeSys |
Standards | CCC, CSA, CSA C22.2 No 60947-4-1, DNV-GL, EAC, EN/IEC 60947-4-1, EN/IEC 60947-5-1, IEC 60335-1, KC, LROS, UKCA, UL Listed, UL 60947-4-1 |
Auxiliary Contact Form | 1NO/1NC |
NEMA Size | Not Applicable |
Series | TeSys Deca |
Fire Rating | UL 94 V1 |
Tightening Torque | 1.7 Nm |
Overvoltage Category | CAT III |
Hold VA | 0.9 VA |
Features | Built-In Bi-Directional Peak Limiting, Preassembled with Reversing Power Busbar |
Electrical Connection | Screw Clamp Terminals |
Mechanical Durability | 15 Mcycles |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Signalling Circuit Frequency | 25 to 400 Hz |
Electrical Durability | 2.2 Mcycles (15 A, AC-3, Less than 440 V), 0.9 Mcycles (32 A, AC-1, Less than 440 V) |
Impedance | 2.5 mOhm |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
Watts Loss | 0.6W |
Max. Temperature | 850°C |
Impulse Withstand Voltage | 6 kV |
Control Circuit Voltage Limits | Drop-Out AC/DC: Less Than 0.1 Uc (at -40 to 70°C), Operational AC: 0.85 to 1.1 Uc (at -40 to 60°C), Operational DC: 0.8 to 1.1 Uc (at -40 to 60°C), Operational AC/DC 1 to 1.1 Uc (at 60 to 70°C) |
Switching Voltage | 17 V (Signalling Circuit) |
Max. Operating Watts | 4 kW (at 220 to 230V AC 50 Hz), 7.5 kW (at 380 to 400V AC 50 Hz), 9 kW (at 415V AC 50 Hz), 9 kW (at 440V AC 50 Hz), 10 kW (at 500V AC 50 Hz), 10 kW (at 660 to 690V AC 50 Hz) |
Application | Motor Control, Resistive Load |
Fuse Amps | 10 A (Signalling Circuit), 50 A (Type 1 Power Circuit), 35 A (Type 2 Power Circuit) |
Environmental Attributes | Mercury Free, Pollution Degree 3 |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Net Weight | 0.803 kg |
Rated Short-Time Withstand Current | 40 A (at 40°C for 10 min Power Circuit), 84 A (at 40°C for 1 min Power Circuit), 145 A (at 40°C for 10 s Power Circuit), 240 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Operating Speed | 3600 cycles per hr |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 300 A @ 440V (Power Circuit) |
Rated Breaking Capacity | 300 A @ 440V |
Includes Protective Cover | Yes |
Operating Time | 45 to 55 ms (Closing), 20 to 90 ms (Opening) |
IP Rating | IP20 |
Thermal Amperage | 32 A (at 60°C Power Circuit), 10 A (at 60°C Signalling Circuit) |
Rated Insulation Volts | 690V |
Non-Overlap Time | 1.5 ms |
Inrush VA | 15 VA |
Switching Current | 5 mA (Signalling Circuit) |
Rated Voltage | 690V AC |
Mounts On | Plate, Rail |
Working Height | Up to 9842.52 ft |
Frequency | 50/60 Hz |
Full Load Current - Inductive | 18 A |
Horsepower @ Three Phase - 208V AC | 5 hp |
Embedded Surge Suppressor | No |
Terminal Connection Type | Screw Clamp Terminals |
Resistance Properties | Fire Resistant, Insulation Resistant |
Maximum Operating Temperature | 140 Degrees F |
Horsepower @ Three Phase - 240V AC | 5 hp |
Electrical Operating Durability | 2,200,000, 900,000 |
Reversing Capability | Reversing |
Maximum Voltage Rating | 690V AC |
Mechanical Operating Durability | 15,000,000 |
Number of Normally Open Main Contacts | 3 |
Horsepower @ Single Phase - 120V AC | 1 hp |
NEMA Enclosure Rating | No Enclosure |
Overall Depth | 3.39 in |
Coil Voltage | 24-60V AC/DC |
Horsepower @ Three Phase - 480V AC | 10 hp |
Number of Auxillary Contacts | 2 |
Minimum Operating Temperature | -40 Degrees F |
Horsepower @ Three Phase - 600V AC | 15 hp |
Contactor Style | IEC |
Horsepower @ Single Phase - 240V AC | 3 hp |
Overall Height | 3.03 in |
Includes Auxiliary Contacts | Yes |
NEMA Enclosure Material | Not Applicable |
Overall Width | 3.54 in |
Mounting Style | DIN Rail, Plate |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 24 to 60 V AC/DC, 18 A, Reversing: Yes, SCHNEIDER ELECTRIC, Mfr# LC2D18BNE
$166,99
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24-60V AC/DC, Number of Poles 3, Full Load Current - Inductive 18 A, Reversing Capability Reversing, Overall Height 3.03 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC, Horsepower @ Three Phase - 240V AC 5 hp
9999 in stock
Must order in multiples of 1
Subtotal:
$166.99
You must be logged in to post a review.
Reviews