Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 40 A |
Full Load Amps-Resistive | 60 A |
Number of Poles | 3 |
Coil Volts | 24 to 60 V AC/DC |
Reversing | Yes |
HP @ 1 Phase - 120V | 3 hp |
Height | 4.8 in |
HP @ 1 Phase - 240V | 5 hp |
HP @ 3 Phase - 208V | 10 hp |
Width | 4.69 in |
Depth | 4.72 in |
HP @ 3 Phase - 575V | 30 hp |
HP @ 3 Phase - 240V | 10 hp |
HP @ 3 Phase - 480V | 30 hp |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Standards | CCC, CSA, CSA C22.2 No 60947-4-1, DNV-GL, EAC, EN/IEC 60947-4-1, EN/IEC 60947-5-1, IEC 60335-1, KC, LROS, UKCA, UL Listed, UL 60947-4-1 |
Frame / Series / Class / Code | TeSys |
NEMA Size | Not Applicable |
Auxiliary Contact Form | 1NO/1NC |
Series | TeSys Deca |
Electrical Connection | Control Circuit: Screw Clamp Terminals, Power Circuit: EverLink BTR Screw Connectors |
Max. Temperature | 850°C |
Overvoltage Category | CAT III |
Includes Protective Cover | Yes |
Electrical Durability | 2 Mcycles (35 A, AC-3, Less than 440 V), 0.7 Mcycles (60 A, AC-1, Less than 440 V) |
Signalling Circuit Frequency | 25 to 400 Hz |
Rated Insulation Volts | 690V |
Working Height | Up to 9842.52 ft |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 800 A @ 440V (Power Circuit) |
Operating Speed | 3600 cycles per hr |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Switching Voltage | 17 V (Signalling Circuit) |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 60 A (at 60°C Power Circuit) |
IP Rating | IP20 |
Rated Voltage | 690V AC |
Environmental Attributes | Mercury Free, Pollution Degree 3 |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Max. Operating Watts | 11 kW (at 220 to 230V AC 50 Hz), 18.5 kW (at 380 to 400V AC 50 Hz), 22 kW (at 415V AC 50 Hz), 22 kW (at 440V AC 50 Hz), 22 kW (at 500V AC 50 Hz), 30 kW (at 660 to 690V AC 50 Hz) |
Fire Rating | UL 94 V1 |
Hold VA | 1 VA |
Switching Current | 5 mA (Signalling Circuit) |
Control Circuit Voltage Limits | Drop-Out AC/DC: Less Than 0.1 Uc (at -40 to 70°C), Operational AC: 0.85 to 1.1 Uc (at -40 to 60°C), Operational DC: 0.8 to 1.1 Uc (at -40 to 60°C), Operational AC/DC 1 to 1.1 Uc (at 60 to 70°C) |
Operating Time | 55 to 65 ms (Closing), 20 to 120 ms (Opening) |
Rated Breaking Capacity | 800 A @ 440V |
Application | Motor Control, Resistive Load |
Fuse Amps | 10 A (Signalling Circuit), 80 A (Type 1 Power Circuit), 80 A (Type 2 Power Circuit) |
Features | Built-In Bi-Directional Peak Limiting, Preassembled with Reversing Power Busbar |
Mechanical Durability | 6 Mcycles |
Inrush VA | 15 VA |
Watts Loss | 0.7W |
Mounts On | Plate, Rail |
Rated Short-Time Withstand Current | 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit), 320 A (at 40°C for 10 s Power Circuit), 720 A (at 40°C for 1 s Power Circuit), 72 A (at 40°C for 10 min Power Circuit), 165 A (at 40°C for 1 min Power Circuit) |
Impedance | 1.5 mOhm |
Impulse Withstand Voltage | 6 kV |
Net Weight | 2.154 kg |
Tightening Torque | 1.7 Nm (Control Circuit), 5 to 8 Nm (Power Circuit) |
Non-Overlap Time | 1.5 ms |
Full Load Current - Inductive | 40 A |
Maximum Operating Temperature | 140 Degrees F |
Full Load Current - Resistive | 60 A |
Horsepower @ Single Phase - 240V AC | 5 hp |
Horsepower @ Three Phase - 208V AC | 10 hp |
Terminal Connection Type | Screw Clamp Terminals |
Contactor Style | IEC |
Overall Height | 4.8 in |
NEMA Enclosure Material | Not Applicable |
Number of Normally Open Main Contacts | 3 |
Coil Voltage | 24-60V AC/DC |
Number of Auxillary Contacts | 2 |
Minimum Operating Temperature | -40 Degrees F |
Horsepower @ Three Phase - 600V AC | 30 hp |
Horsepower @ Three Phase - 240V AC | 10 hp |
Resistance Properties | Fire Resistant, Insulation Resistant |
Horsepower @ Single Phase - 120V AC | 3 hp |
Reversing Capability | Reversing |
Includes Auxiliary Contacts | Yes |
Embedded Surge Suppressor | No |
Frequency | 50/60 Hz |
Maximum Voltage Rating | 690V AC |
Electrical Operating Durability | 2,000,000, 700,000 |
Overall Width | 4.69 in |
Overall Depth | 4.72 in |
Horsepower @ Three Phase - 480V AC | 30 hp |
Mechanical Operating Durability | 6,000,000 |
NEMA Enclosure Rating | No Enclosure |
Mounting Style | DIN Rail, Plate |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 24 to 60 V AC/DC, 40 A, Reversing: Yes, SCHNEIDER ELECTRIC, Mfr# LC2D40ABNE
$310,99
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24-60V AC/DC, Number of Poles 3, Full Load Current - Inductive 40 A, Full Load Current - Resistive 60 A, Reversing Capability Reversing, Overall Height 4.8 in, Overall Width 4.69 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$310.99
You must be logged in to post a review.
Reviews
There are no reviews yet.