Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 65 A |
Full Load Amps-Resistive | 80 A |
Number of Poles | 3 |
Coil Volts | 24 to 60 V AC/DC |
Reversing | Yes |
HP @ 1 Phase - 120V | 5 hp |
HP @ 1 Phase - 240V | 10 hp |
Height | 4.8 in |
HP @ 3 Phase - 208V | 20 hp |
Width | 4.69 in |
HP @ 3 Phase - 575V | 50 hp |
HP @ 3 Phase - 240V | 20 hp |
Depth | 4.72 in |
HP @ 3 Phase - 480V | 40 hp |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Frame / Series / Class / Code | TeSys |
Standards | CCC, CSA, CSA C22.2 No 60947-4-1, DNV-GL, EAC, EN/IEC 60947-4-1, EN/IEC 60947-5-1, IEC 60335-1, KC, LROS, UKCA, UL Listed, UL 60947-4-1 |
Series | TeSys Deca |
NEMA Size | Not Applicable |
Auxiliary Contact Form | 1NO/1NC |
Impedance | 1.5 mOhm |
Max. Temperature | 850°C |
Inrush VA | 15 VA |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Max. Operating Watts | 18.5 kW (at 220 to 230V AC 50 Hz), 30 kW (at 380 to 400V AC 50 Hz), 37 kW (at 415V AC 50 Hz), 37 kW (at 440V AC 50 Hz), 37 kW (at 500V AC 50 Hz), 37 kW (at 660 to 690V AC 50 Hz) |
Impulse Withstand Voltage | 6 kV |
Hold VA | 1 VA |
Application | Motor Control, Resistive Load |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 80 A (at 60°C Power Circuit) |
Overvoltage Category | CAT III |
Working Height | Up to 9842.52 ft |
Environmental Attributes | Mercury Free, Pollution Degree 3 |
Mounts On | Plate, Rail |
Watts Loss | 0.7W |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1000 A @ 440V (Power Circuit) |
Rated Breaking Capacity | 1000 A @ 440V |
Switching Voltage | 17 V (Signalling Circuit) |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
Mechanical Durability | 6 Mcycles |
Rated Insulation Volts | 690V |
Fuse Amps | 10 A (Signalling Circuit), 125 A (Type 1 Power Circuit), 125 A (Type 2 Power Circuit) |
IP Rating | IP20 |
Electrical Connection | Control Circuit: Screw Clamp Terminals, Power Circuit: EverLink BTR Screw Connectors |
Includes Protective Cover | Yes |
Signalling Circuit Frequency | 25 to 400 Hz |
Rated Voltage | 690V AC |
Fire Rating | UL 94 V1 |
Operating Time | 55 to 65 ms (Closing), 20 to 120 ms (Opening) |
Electrical Durability | 1.8 Mcycles (57 A, AC-3, Less than 440 V), 0.5 Mcycles (80 A, AC-1, Less than 440 V) |
Tightening Torque | 1.7 Nm (Control Circuit), 5 to 8 Nm (Power Circuit) |
Switching Current | 5 mA (Signalling Circuit) |
Net Weight | 2.174 kg |
Non-Overlap Time | 1.5 ms |
Rated Short-Time Withstand Current | 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit), 520 A (at 40°C for 10 s Power Circuit), 900 A (at 40°C for 1 s Power Circuit), 110 A (at 40°C for 10 min Power Circuit), 260 A (at 40°C for 1 min Power Circuit) |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Features | Built-In Bi-Directional Peak Limiting, Preassembled with Reversing Power Busbar |
Operating Speed | 3600 cycles per hr |
Control Circuit Voltage Limits | Drop-Out AC/DC: Less Than 0.1 Uc (at -40 to 70°C), Operational AC: 0.85 to 1.1 Uc (at -40 to 60°C), Operational DC: 0.8 to 1.1 Uc (at -40 to 60°C), Operational AC/DC 1 to 1.1 Uc (at 60 to 70°C) |
Horsepower @ Single Phase - 120V AC | 5 hp |
Frequency | 50/60 Hz |
Overall Depth | 4.72 in |
Maximum Voltage Rating | 690V AC |
Minimum Operating Temperature | -40 Degrees F |
Contactor Style | IEC |
Resistance Properties | Fire Resistant |
Includes Auxiliary Contacts | Yes |
NEMA Enclosure Material | Not Applicable |
Embedded Surge Suppressor | No |
Horsepower @ Three Phase - 480V AC | 40 hp |
Maximum Operating Temperature | 140 Degrees F |
Horsepower @ Three Phase - 600V AC | 50 hp |
Coil Voltage | 24-60V AC/DC |
Overall Height | 4.8 in |
Number of Auxillary Contacts | 2 |
Reversing Capability | Reversing |
NEMA Enclosure Rating | No Enclosure |
Mounting Style | DIN Rail, Plate |
Number of Normally Open Main Contacts | 3 |
Full Load Current - Inductive | 65 A |
Full Load Current - Resistive | 80 A |
Horsepower @ Single Phase - 240V AC | 10 hp |
Overall Width | 4.69 in |
Horsepower @ Three Phase - 208V AC | 20 hp |
Mechanical Operating Durability | 6,000,000 |
Horsepower @ Three Phase - 240V AC | 20 hp |
Electrical Operating Durability | 1,800,000, 500,000 |
Terminal Connection Type | Screw Clamp Terminals |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 24 to 60 V AC/DC, 65 A, Reversing: Yes, SCHNEIDER ELECTRIC, Mfr# LC2D65ABNE
$409,99
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24-60V AC/DC, Number of Poles 3, Full Load Current - Inductive 65 A, Full Load Current - Resistive 80 A, Reversing Capability Reversing, Overall Height 4.8 in, Overall Width 4.69 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$409.99
You must be logged in to post a review.
Reviews
There are no reviews yet.