Discount -2%

IEC Magnetic Contactor, 3 Poles, 120 V AC, 25 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D25G7

$172.65

Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 120V AC, Number of Poles 3, Full Load Current - Inductive 25 A, Full Load Current - Resistive 40 A, Reversing Capability Non-Reversing, Overall Height 3.35 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$172.65
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC1D25G7
Availability: Ships in 1 days
SKU: GRG0464597 Category:
Full Load Amps-Inductive25 A
ItemIEC Magnetic Contactor
ActionNon-Reversing
Full Load Amps-Resistive40 A
Number of Poles3
Coil Volts120 V AC
ReversingNo
HP @ 1 Phase - 120V2 hp
HP @ 1 Phase - 230V3
Height3.36 in
HP @ 1 Phase - 240V3 hp
HP @ 3 Phase - 208V7 1/2 hp
Width1.77 in
HP @ 3 Phase - 575V20 hp
HP @ 3 Phase - 240V7 1/2 hp
Depth3.62 in
HP @ 3 Phase - 480V15 hp
Enclosure NEMA RatingNo Enclosure
Aux. Contact Configuration1NO/1NC
Hz50/60
Auxiliary Contact Form1NO/1NC
Frame / Series / Class / CodeTeSys
StandardsBV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
NEMA SizeNot Applicable
SeriesTeSys Deca
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Operating Time12 to 22 ms (Closing), 4 to 19 ms (Opening)
Max. Temperature850°C
Net Weight0.37 kg
Watts Loss2 to 3W
Thermal Amperage10 A (at 60°C Signalling Circuit), 40 A (at 60°C Power Circuit)
Fire RatingUL 94 V1
Rated Insulation Volts600/690V
Electrical ConnectionScrew Clamp Terminals
Mechanical Durability15 Mcycles
Fuse Amps10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 40 A (Type 2 Power Circuit)
Impulse Withstand Voltage6 kV
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Inrush VA70 VA
Control Circuit Voltage LimitsDrop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Working HeightUp to 9842.52 ft
Tightening Torque1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit)
Shock Resistance8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Mounts OnPlate, Rail
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Impedance2 mOhm
Rated Voltage690V AC, 300V DC
Rated Short-Time Withstand Current240 A (at 40°C for 10 s Power Circuit), 380 A (at 40°C for 1 s Power Circuit), 50 A (at 40°C for 10 min Power Circuit), 120 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Includes Protective CoverYes
Rated Breaking Capacity450 A @ 440V
FeaturesWithout Built-In Suppressor Module
ApplicationMotor Control, Resistive Load
Max. Operating Watts5.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 11 kW (at 380 to 400V AC 50/60 Hz AC-3), 11 kW (at 415 to 440V AC 50/60 Hz AC-3), 15 kW (at 500V AC 50/60 Hz AC-3), 15 kW (at 660 to 690V AC 50/60 Hz AC-3), 5.5 kW (at 400V AC 50/60 Hz AC-4), 5.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 11 kW (at 380 to 400V AC 50/60 Hz AC-3e), 11 kW (at 415 to 440V AC 50/60 Hz AC-3e), 15 kW (at 500V AC 50/60 Hz AC-3e), 15 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Electrical Durability1.65 Mcycles (25 A, AC-3, Less than 440 V), 1.4 Mcycles (40 A, AC-1, Less than 440 V), 1.65 Mcycles (25 A, AC-3e, Less than 440 V)
Hold VA7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Non-Overlap Time1.5 ms
Signalling Circuit Frequency25 to 400 Hz
Operating Speed3600 cycles per hr
Switching Voltage17 V (Signalling Circuit)
Switching Current5 mA (Signalling Circuit)
Overvoltage CategoryCAT III
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit)
IP RatingIP20
Terminal Connection TypeScrew Clamp Terminals
Full Load Current - Resistive40 A
Frequency50/60 Hz
NEMA Enclosure RatingNo Enclosure
Maximum Voltage Rating690V AC
Resistance PropertiesFire Resistant, Insulation Resistant
Overall Height3.35 in
Horsepower @ Single Phase - 240V AC3 hp
Full Load Current - Inductive25 A
NEMA Enclosure MaterialNot Applicable
Horsepower @ Three Phase - 600V AC20 hp
Coil Voltage120V AC
Horsepower @ Single Phase - 120V AC2 hp
Number of Normally Open Main Contacts3
Horsepower @ Three Phase - 240V AC7 1/2 hp
Mechanical Operating Durability15,000,000
Reversing CapabilityNon-Reversing
Includes Auxiliary ContactsYes
Minimum Operating Temperature-40 Degrees F
Embedded Surge SuppressorNo
Electrical Operating Durability1,400,000, 1,650,000
Number of Auxillary Contacts2
Mounting StyleDIN Rail, Plate
PhaseThree
Overall Depth3.62 in
Contactor StyleIEC
Maximum Operating Temperature140 Degrees F
Overall Width1.77 in
Horsepower @ Three Phase - 480V AC15 hp
Horsepower @ Three Phase - 208V AC7 1/2 hp
Rated Insulation VoltagePower circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL
Rated Short Time Withstand Current240 A 104°F (40°C) - 10 s for power circuit, 380 A 104°F (40°C) - 1 s for power circuit, 50 A 104°F (40°C) - 10 min for power circuit, 120 A 104°F (40°C) - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Poles Description3P
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1, 63 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 40 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Mounting SupportRail, Plate
Pollution Degree3
Control Circuit TypeAC 50/60 Hz
Mechanical RobustnessVibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor closed 15 Gn for 11 ms), Shocks contactor open 8 Gn for 11 ms)
Average Impedance2 mOhm - Ith 40 A 50 Hz for power circuit
Hold-In Power Consumption in VA7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C))
Connections - TerminalsControl circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (1 to 10 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 6 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (1.5 to 10 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: solid without cable end
Rated Operational VoltagePower circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC
Fire Resistance1562°F (850°C) IEC 60695-2-1
Rated Operational Current25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Maximum Horse Power Rating3 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 2 hp at 115 V AC 50/60 Hz for 1 phase motors, 7.5 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 15 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 20 hp at 575/600 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 200/208 V AC 50/60 Hz for 3 phase motors
Maximum Operating Rate3600 cyc/h 140°F (60°C)
Product CertificationsUL, BV, RINA, GOST, DNV, LROS (Lloyds register of shipping), CCC, GL, CSA, UKCA
Operating Altitude0 to 9842.52 ft (0 to 3000 m)
Contactor ApplicationMotor control, Resistive load
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Inrush Power in VA70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Flame RetardanceV1 conforming to UL 94
IRMS Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 450 A at 440 V for power circuit conforming to IEC 60947
Control Circuit Voltage120 V AC 50/60 Hz
IP Degree Of ProtectionIP20 front face IEC 60529
Power Dissipation Per Pole3.2 W AC-1, 1.25 W AC-3, 1.25 W AC-3e
Contact CompatibilityM2
Minimum Switching Voltage17 V for signalling circuit
Product Or Component TypeContactor
Minimum Switching Current5 mA for signalling circuit
Protective CoverWith
Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
Auxiliary Contact Composition1 NO + 1 NC
Compatibility CodeLC1D
Pole Contact Composition3 NO
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Conventional Free Air Thermal Current10 A (at 140°F (60°C)) for signalling circuit, 40 A (at 140°F (60°C)) for power circuit
Protective TreatmentTHIEC 60068-2-30
Heat Dissipation2 to 3 W at 50/60 Hz
Permissible Ambient Air Temperature Around The Device-40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating
Rated Impulse Withstand Voltage6 kV IEC 60947
Utilisation CategoryAC-3, AC-4, AC-1, AC-3e
Motor Power KW5.5 kW at 220 to 230 V AC 50/60 Hz (AC-3), 11 kW at 380 to 400 V AC 50/60 Hz (AC-3), 11 kW at 415 to 440 V AC 50/60 Hz (AC-3), 15 kW at 500 V AC 50/60 Hz (AC-3), 15 kW at 660 to 690 V AC 50/60 Hz (AC-3), 5.5 kW at 400 V AC 50/60 Hz (AC-4), 5.5 kW at 220 to 230 V AC 50/60 Hz (AC-3e), 11 kW at 380 to 400 V AC 50/60 Hz (AC-3e), 11 kW at 415 to 440 V AC 50/60 Hz (AC-3e), 15 kW at 500 V AC 50/60 Hz (AC-3e), 15 kW at 660 to 690 V AC 50/60 Hz (AC-3e)
Country of Origin (subject to change)Indonesia
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#120 V AC
#25 A
#Reversing: No
#SCHNEIDER ELECTRIC
#Mfr LC1D25G7
#SCHNEIDER ELECTRIC
#GRG0464597
#mfr:LC1D25G7
#part number:LC1D25G7
#pn:LC1D25G7
#part code:LC1D25G7
#item number:LC1D25G7
#product code:LC1D25G7
#manufacturer number:LC1D25G7
#manufacturers part number:LC1D25G7
#mfn:LC1D25G7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!