Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 115 A |
Action | Non-Reversing |
Full Load Amps-Resistive | 200 A |
Number of Poles | 3 |
Coil Volts | 24 V DC |
Reversing | No |
Height | 4.33 in |
Width | 4.33 in |
HP @ 3 Phase - 208V | 30 hp |
HP @ 3 Phase - 240V | 40 hp |
HP @ 3 Phase - 575V | 100 hp |
Depth | 5.12 in |
HP @ 3 Phase - 480V | 75 hp |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Auxiliary Contact Form | 1NO/1NC |
Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
Frame / Series / Class / Code | TeSys |
Series | TeSys Deca |
NEMA Size | Not Applicable |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open) |
Non-Overlap Time | 1.5 ms |
Overvoltage Category | CAT III |
Electrical Durability | 0.8 Mcycles (200 A, AC-1, Less than 440 V), 0.95 Mcycles (115 A, AC-3, Less than 440 V), 0.95 Mcycles (115 A, AC-3e, Less than 440 V) |
Rated Insulation Volts | 600/1000V (Power Circuit), 600/690V (Signalling Circuit) |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Net Weight | 2.5 kg |
Includes Protective Cover | Yes |
Switching Voltage | 17 V (Signalling Circuit) |
Rated Making Capacity | 1260 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit) |
Features | With Integral Suppression Device |
Fire Rating | UL 94 V1 |
Switching Current | 5 mA (Signalling Circuit) |
Electrical Connection | Screw Clamp Terminals |
Signalling Circuit Frequency | 25 to 400 Hz |
Max. Operating Watts | 30 kW (at 220 to 230V AC 50/60 Hz AC-3), 55 kW (at 380 to 400V AC 50/60 Hz AC-3), 59 kW 415 to (at 440V AC 50/60 Hz AC-3), 75 kW (at 500V AC 50/60 Hz AC-3), 80 kW (at 660 to 690V AC 50/60 Hz AC-3), 65 kW (at 1000V AC 50/60 Hz AC-3), 18.5 kW (at 400V AC 50/60 Hz AC-4), 30 kW (at 220 to 230V AC 50/60 Hz AC-3e), 55 kW (at 380 to 400V AC 50/60 Hz AC-3e), 59 kW 415 to (at 440V AC 50/60 Hz AC-3e), 75 kW (at 500V AC 50/60 Hz AC-3e), 80 kW (at 660 to 690V AC 50/60 Hz AC-3e), 65 kW (at 1000V AC 50/60 Hz AC-3e) |
Working Height | Up to 9842.52 ft |
Max. Temperature | 850°C |
Impedance | 0.6 mOhm |
Environmental Attributes | Mercury Free, PVC Free, Pollution Degree 3 |
Rated Voltage | 1000V AC, 300V DC |
Rated Short-Time Withstand Current | 250 A (at 40°C for 10 min Power Circuit), 550 A (at 40°C for 1 min Power Circuit), 950 A (at 40°C for 10 s Power Circuit), 1100 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Fuse Amps | 250 A (Type 1 Power Circuit), 200 A (Type 2 Power Circuit), 10 A (Signalling Circuit) |
Mechanical Durability | 8 Mcycles |
IP Rating | IP20 |
Impulse Withstand Voltage | 8 kV |
Thermal Amperage | 200 A (at 60°C Power Circuit) |
Operating Time | 20 to 35 ms (Closing), 40 to 75 ms (Opening) |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Control Circuit Voltage Limits | Operational DC: 0.75 to 1.2 Uc (at -40 to 55°C), 1 to 1.2 Uc (at 55 to 70°C), Drop-Out DC: 0.15 to 0.4 Uc (at -40 to 70°C) |
Operating Speed | 1200 cycles per hr |
Mounts On | Plate, Rail |
Application | Motor Control, Resistive Load |
Tightening Torque | 1.2 Nm (Control Circuit), 12 Nm (Power Circuit) |
Rated Breaking Capacity | 1100 A @ 440V |
Embedded Surge Suppressor | Yes |
Horsepower @ Three Phase - 240V AC | 40 hp |
NEMA Enclosure Material | Not Applicable |
Full Load Current - Inductive | 115 A |
Mechanical Operating Durability | 8,000,000 |
Full Load Current - Resistive | 200 A |
Overall Height | 6.22 in |
Phase | Three |
Horsepower @ Single Phase - 240V AC | 1 hp |
Resistance Properties | Fire Resistant, Insulation Resistant |
Reversing Capability | Non-Reversing |
Mounting Style | DIN Rail, Plate |
Contactor Style | IEC |
Includes Auxiliary Contacts | Yes |
Horsepower @ Three Phase - 600V AC | 100 hp |
Horsepower @ Three Phase - 208V AC | 30 hp |
Electrical Operating Durability | 800,000, 950,000 |
Number of Normally Open Main Contacts | 3 |
Minimum Operating Temperature | -40 Degrees F |
Overall Width | 0.47 in |
Frequency | 50/60 Hz |
Maximum Voltage Rating | 1000V AC |
Number of Auxillary Contacts | 2 |
Maximum Operating Temperature | 140 Degrees F |
Overall Depth | 5.35 in |
Terminal Connection Type | Screw Clamp Terminals |
Horsepower @ Three Phase - 480V AC | 75 hp |
Coil Voltage | 24V DC |
NEMA Enclosure Rating | No Enclosure |
Country of Origin (subject to change) | Czechia |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 24 V DC, 115 A, Reversing: No, SCHNEIDER, Mfr# LC1D115BD
$514.09
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V DC, Number of Poles 3, Full Load Current - Inductive 115 A, Full Load Current - Resistive 200 A, Reversing Capability Non-Reversing, Overall Height 6.22 in, Overall Width 0.47 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$514.09
You must be logged in to post a review.
Reviews
There are no reviews yet.