Full Load Amps-Inductive | 65 A |
Item | IEC Magnetic Contactor |
Action | Non-Reversing |
Full Load Amps-Resistive | 80 A |
Number of Poles | 3 |
Coil Volts | 480 V AC |
Reversing | No |
HP @ 1 Phase - 120V | 5 hp |
HP @ 1 Phase - 230V | 10 |
HP @ 1 Phase - 240V | 10 hp |
Height | 4.8 in |
HP @ 3 Phase - 208V | 20 hp |
Width | 2.17 in |
Depth | 4.72 in |
HP @ 3 Phase - 240V | 20 hp |
HP @ 3 Phase - 575V | 50 hp |
Enclosure NEMA Rating | No Enclosure |
HP @ 3 Phase - 480V | 40 hp |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Auxiliary Contact Form | 1NO/1NC |
Standards | CCC, CSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, UL Listed |
Includes | Everlink Power Connections |
NEMA Size | Not Applicable |
Series | TeSys Deca |
Fire Rating | UL 94 V1 |
Electrical Durability | 1.4 Mcycles (80 A, AC-1, Less than 440 V), 1.45 Mcycles (65 A, AC-3, Less than 440 V), 1.45 Mcycles (65 A, AC-3e, Less than 440 V) |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Shock Resistance | 10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed) |
Rated Insulation Volts | 600/690V |
Mechanical Durability | 6 Mcycles |
Rated Short-Time Withstand Current | 520 A (at 40°C for 10 s Power Circuit), 900 A (at 40°C for 1 s Power Circuit), 110 A (at 40°C for 10 min Power Circuit), 260 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 60 Hz) , Operational AC: 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 60 Hz) |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Operating Time | 4 to 19 ms (Opening), 12 to 26 ms (Closing) |
Working Height | Up to 9842.52 ft |
Includes Protective Cover | Yes |
Inrush VA | 140 VA |
Rated Breaking Capacity | 1000 A @ 440V |
Max. Operating Watts | 11 kW (at 400V AC 50/60 Hz AC-4), 18.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 30 kW (at 380 to 400V AC 50/60 Hz AC-3), 37 kW (at 500V AC 50/60 Hz AC-3), 37 kW (at 660 to 690V AC 50/60 Hz AC-3), 18.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 30 kW (at 380 to 400V AC 50/60 Hz AC-3e), 37 kW (at 500V AC 50/60 Hz AC-3e), 37 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
Signalling Circuit Frequency | 25 to 400 Hz |
Net Weight | 0.86 kg |
Switching Voltage | 17 V (Signalling Circuit) |
Rated Voltage | 690V AC, 300V DC |
Watts Loss | 4 to 5W |
Electrical Connection | Control Circuit: Screw Clamp Terminals, Power Circuit: EverLink BTR Screw Connectors |
Application | Motor Control, Resistive Load |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 80 A (at 60°C Power Circuit) |
Fuse Amps | 10 A (Signalling Circuit), 125 A (Type 1 Power Circuit), 125 A (Type 2 Power Circuit) |
Switching Current | 5 mA (Signalling Circuit) |
Mounts On | Plate, Rail |
Overvoltage Category | CAT III |
Impulse Withstand Voltage | 6 kV |
Tightening Torque | 1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit) |
IP Rating | IP20 |
Max. Temperature | 850°C |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1000 A @ 440V (Power Circuit) |
Operating Speed | 3600 cycles per hr |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Features | Without Built-In Suppressor Module |
Impedance | 1.5 mOhm |
Non-Overlap Time | 1.5 ms |
Hold VA | 13 VA |
Frequency | 50/60 Hz |
Horsepower @ Single Phase - 120V AC | 5 hp |
Embedded Surge Suppressor | No |
Terminal Connection Type | Screw Clamp Terminals |
Horsepower @ Three Phase - 600V AC | 50 hp |
Overall Width | 2.17 in |
Mounting Style | DIN Rail, Plate |
Coil Voltage | 480V AC |
Minimum Operating Temperature | -40 Degrees F |
Full Load Current - Inductive | 65 A |
Number of Normally Open Main Contacts | 3 |
Horsepower @ Three Phase - 480V AC | 40 hp |
Electrical Operating Durability | 1,400,000, 1,450,000 |
Full Load Current - Resistive | 80 A |
Horsepower @ Three Phase - 240V AC | 20 hp |
Contactor Style | IEC |
Phase | Three |
Maximum Operating Temperature | 140 Degrees F |
Overall Depth | 4.72 in |
Overall Height | 4.8 in |
Includes Auxiliary Contacts | Yes |
NEMA Enclosure Material | Not Applicable |
Reversing Capability | Non-Reversing |
Resistance Properties | Fire Resistant, Insulation Resistant |
NEMA Enclosure Rating | No Enclosure |
Number of Auxillary Contacts | 2 |
Horsepower @ Single Phase - 240V AC | 10 hp |
Maximum Voltage Rating | 690V AC |
Horsepower @ Three Phase - 208V AC | 20 hp |
Mechanical Operating Durability | 6,000,000 |
Country of Origin (subject to change) | Multiple |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 480 V AC, 65 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D65AT7
$395.75
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 480V AC, Number of Poles 3, Full Load Current - Inductive 65 A, Full Load Current - Resistive 80 A, Reversing Capability Non-Reversing, Overall Height 4.8 in, Overall Width 2.17 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC