IEC Mini Magnetic Contactor, 3 Poles, 24 V DC, 6 A, Reversing: Yes, SCHNEIDER, Mfr# LP2K0601BD

$175.56

Free shipping will be applied on orders over $50

Miniature IEC Magnetic Contactor, Auxiliary Contact Form 1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V DC, Number of Poles 3, Full Load Current - Inductive 6 A, Full Load Current - Resistive 15 A, Reversing Capability Reversing, Overall Height 2.28 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys K, Number of Auxillary Contacts 1, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$175.56
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER
Mfr #: LP2K0601BD
Availability: Ships in 1 days
SKU: GRG0682297 Category:
ItemMiniature IEC Magnetic Contactor
Full Load Amps-Inductive6 A
ActionReversing
Full Load Amps-Resistive15 A
Number of Poles3
Coil Volts24 V DC
ReversingYes
HP @ 1 Phase - 120V1/2 hp
HP @ 1 Phase - 230V1-1/2
Height3.54 in
HP @ 1 Phase - 240V1 1/2 hp
HP @ 3 Phase - 208V1 1/2 hp
Width3.54 in
Depth2.24 in
HP @ 3 Phase - 240V1 1/2 hp
HP @ 3 Phase - 575V3 hp
HP @ 3 Phase - 480V3 hp
Enclosure NEMA RatingNo Enclosure
Aux. Contact Configuration1NC
Hz50/60
StandardsBS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660
Auxiliary Contact Form1NC
SeriesTeSys K
NEMA SizeNot Applicable
Switching Voltage17 V (Signalling Circuit)
Rated Short-Time Withstand Current90 A (at 50°C for 1 s Power Circuit), 85 A (at 50°C for 5 s Power Circuit), 80 A (at 50°C for 10 s Power Circuit), 60 A (at 50°C for 30 s Power Circuit), 45 A (at 50°C for 1 min Power Circuit), 40 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 20 A (at 50°C for 15 min Power Circuit)
Electrical Durability1.3 Mcycles (6 A, AC-3, Less than 440 V), 1.3 Mcycles (6 A, AC-3e, Less than 440 V)
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Impulse Withstand Voltage8 kV
Control Circuit Voltage LimitsOperational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.1 to 0.75 Uc (at 50°C)
IP RatingIP20
Mechanical Durability5 Mcycles
Mounts OnPlate, Rail
Switching Current5 mA (Signalling Circuit)
Environmental AttributesMercury Free, Toxic Heavy Metal Free
Rated Voltage690V AC
Rated Insulation Volts600/690V
Tightening Torque0.8 to 1.3 Nm
Rated Making Capacity110 A
Shock Resistance10 G for 11 ms (on Y axis with Contactor Closed), 15 G for 11 ms (on X and Z axis with Contactor Closed), 6 G for 11 ms (on Y axis with Contactor Open), 10 G for 11 ms (on X and Z axis with Contactor Open)
Working Height6561.68 ft
Impedance3 mOhm
Rated Breaking Capacity110 A @ 415V, 440V, 220 to 230V, 380 to 400 V, 80 A @ 500V, 70 A @ 660 to 690V
Watts Loss3W
Thermal Amperage20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit)
ApplicationMotor Control
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Fire RatingUL 94 V1, NF F 16-101, NF F 16-102
Operating Time30 to 40 ms (Coil Energisation and NO Closing), 10 ms (Coil De-Energisation and NO Opening)
Net Weight0.48 kg
Fuse Amps25 A (Power Circuit), 10 A (Signalling Circuit)
Max. Operating Watts1.5 kW (at 220 to 230V AC 50/60 Hz), 2.2 kW (at 380 to 415VAC 50/60 Hz), 3 kW (at 440V AC 50/60 Hz), 3 kW (at 480V AC 50/60 Hz), 3 kW (at 500 to 600V AC 50/60 Hz), 3 kW (at 660 to 690V AC 50/60 Hz)
Electrical ConnectionScrew Clamp Terminals
Operating Speed3600 cycles per hr
Overvoltage CategoryCAT III
FeaturesPreassembled with Reversing Power Busbar
Reversing CapabilityReversing
Maximum Voltage Rating690V AC
Overall Width3.54 in
Horsepower @ Three Phase - 480V AC3 hp
Number of Normally Open Main Contacts3
NEMA Enclosure MaterialNot Applicable
Contactor StyleIEC
Electrical Operating Durability1,300,000
Includes Auxiliary ContactsYes
Minimum Operating Temperature-13 Degrees F
Mounting StyleDIN Rail, Plate
Full Load Current - Inductive6 A
Mechanical Operating Durability5,000,000
Horsepower @ Single Phase - 120V AC1/2 hp
Maximum Operating Temperature122 Degrees F
Embedded Surge SuppressorNo
Frequency50/60 Hz
Horsepower @ Single Phase - 240V AC1 1/2 hp
Horsepower @ Three Phase - 600V AC3 hp
Horsepower @ Three Phase - 240V AC1 1/2 hp
Full Load Current - Resistive15 A
Overall Depth2.24 in
Overall Height2.28 in
Horsepower @ Three Phase - 208V AC1 1/2 hp
NEMA Enclosure RatingNo Enclosure
Coil Voltage24V DC
Resistance PropertiesInsulation Resistant
Number of Auxillary Contacts1
Terminal Connection TypeScrew Clamp Terminals
Motor Power KW1.5 kW 220 to 230 V AC 50/60 Hz, 2.2 kW 380 to 415 V AC 50/60 Hz, 3 kW 440/690 V AC 50/60 Hz
Ambient Air Temperature For Storage-58 to 176°F (-50 to 80°C)
Hold-In Power Consumption in W3 W 68°F (20°C)
Mounting SupportPlate, Rail
Product Or Component TypeReversing contactor
Protective TreatmentTC IEC 60068, TC DIN 50016
Auxiliary Contacts TypeInstantaneous 1 NC
Heat Dissipation3 W
Utilisation CategoryAC-3, AC-3e, AC-4
Control Circuit TypeDC standard
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Maximum Operating Rate3600 cyc/h
Product CertificationsCB Scheme, CCC, UL, CSA, EAC, CE, UKCA
Auxiliary Contact Composition1 NC
Associated Fuse Rating25 A gG at Less than or Equal to 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660
Conventional Free Air Thermal Current20 A (at 140°F (60°C)) for power circuit, 10 A (at 122°F (50°C)) for signalling circuit
IRMS Rated Making Capacity110 A AC for power circuit conforming to IEC 60947, 110 A AC for signalling circuit conforming to IEC 60947
Device ApplicationControl
Inrush Power in W3 W 68°F (20°C))
Minimum Switching Current5 mA for signalling circuit
Rated Short Time Withstand Current90 A 122°F (50°C) - 1 s for power circuit, 85 A 122°F (50°C) - 5 s for power circuit, 80 A 122°F (50°C) - 10 s for power circuit, 60 A 122°F (50°C) - 30 s for power circuit, 45 A 122°F (50°C) - 1 min for power circuit, 40 A 122°F (50°C) - 3 min for power circuit, 20 A 122°F (50°C) - Greater than or Equal to 15 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit, 110 A - 100 ms for signalling circuit
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Connections - Terminalsscrew clamp terminals 1 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 1 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 1 0.00 to 0.00 in? (0.34 to 2.5 mm?)flexible with cable end, screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 2 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 2 0.00 to 0.00 in? (0.34 to 1.5 mm?)flexible with cable end
Flame RetardanceV1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102
IP Degree Of ProtectionIP20 VDE 0106
Mechanical RobustnessShocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27, Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6, Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6, Shocks contactor opened, on X axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Y axis6 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on X axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Y axis10 Gn for 11 ms IEC 60068-2-27
Minimum Switching Voltage17 V for signalling circuit
Rated Operational Current6 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 6 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Ambient Air Temperature For Operation-13 to 122°F (-25 to 50°C)
Interlocking TypeMechanical
Rated Operational VoltagePower circuit 690 V AC 50/60 Hz, Signalling circuit Less than or Equal to 690 V AC 50/60 Hz
Poles Description3P
Operating Altitude6561.68 ft (2000 m) without derating
Non Overlap Distance0.02 in (0.5 mm)
Average Impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Power Pole Contact Composition3 NO
Rated Insulation VoltagePower circuit 600 V UL 508, Power circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-5-1, Signalling circuit 600 V UL 508, Power circuit 600 V CSA C22.2 No 14, Signalling circuit 600 V CSA C22.2 No 14
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#IEC Mini Magnetic Contactor
#3 Poles
#24 V DC
#6 A
#Reversing: Yes
#SCHNEIDER
#Mfr LP2K0601BD
#SCHNEIDER
#GRG0682297
#mfr:LP2K0601BD
#part number:LP2K0601BD
#pn:LP2K0601BD
#part code:LP2K0601BD
#item number:LP2K0601BD
#product code:LP2K0601BD
#manufacturer number:LP2K0601BD
#manufacturers part number:LP2K0601BD
#mfn:LP2K0601BD

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!