Discount -3%

IEC Mini Magnetic Contactor, 3 Poles, 24 V DC, 9 A, Reversing: Yes, SCHNEIDER, Mfr# LP2K0901BD

$212.42

Free shipping will be applied on orders over $50

Miniature IEC Magnetic Contactor, Auxiliary Contact Form 1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V DC, Number of Poles 3, Full Load Current - Inductive 9 A, Full Load Current - Resistive 20 A, Reversing Capability Reversing, Overall Height 2.28 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys K, Number of Auxillary Contacts 1, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$212.42
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER
Mfr #: LP2K0901BD
Availability: Ships in 1 days
SKU: GRG1646337 Category:
ItemMiniature IEC Magnetic Contactor
Full Load Amps-Inductive9 A
ActionReversing
Full Load Amps-Resistive20 A
Number of Poles3
Coil Volts24 V DC
ReversingYes
HP @ 1 Phase - 120V1/2 hp
HP @ 1 Phase - 230V1-1/2
Height3.54 in
HP @ 1 Phase - 240V1 1/2 hp
HP @ 3 Phase - 208V2 hp
Width3.54 in
HP @ 3 Phase - 240V3 hp
HP @ 3 Phase - 575V5 hp
Depth2.24 in
HP @ 3 Phase - 480V5 hp
Enclosure NEMA RatingNo Enclosure
Aux. Contact Configuration1NC
Hz50/60
Auxiliary Contact Form1NC
StandardsBS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660
SeriesTeSys K
NEMA SizeNot Applicable
Control Circuit Voltage LimitsOperational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.1 to 0.75 Uc (at 50°C)
Thermal Amperage20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit)
Impulse Withstand Voltage8 kV
Operating Speed3600 cycles per hr
Rated Insulation Volts600/690V
Rated Short-Time Withstand Current90 A (at 50°C for 1 s Power Circuit), 85 A (at 50°C for 5 s Power Circuit), 80 A (at 50°C for 10 s Power Circuit), 60 A (at 50°C for 30 s Power Circuit), 45 A (at 50°C for 1 min Power Circuit), 40 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 20 A (at 50°C for 15 min Power Circuit)
FeaturesPreassembled with Reversing Power Busbar
ApplicationMotor Control, Resistive Load
IP RatingIP20
Mounts OnPlate, Rail
Impedance3 mOhm
Switching Voltage17 V (Signalling Circuit)
Fuse Amps25 A (Power Circuit), 10 A (Signalling Circuit)
Working Height6561.68 ft
Shock Resistance10 G for 11 ms (on Y axis with Contactor Closed), 15 G for 11 ms (on X and Z axis with Contactor Closed), 6 G for 11 ms (on Y axis with Contactor Open), 10 G for 11 ms (on X and Z axis with Contactor Open)
Rated Voltage690V AC
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Fire RatingUL 94 V1, NF F 16-101, NF F 16-102
Operating Time30 to 40 ms (Coil Energisation and NO Closing), 10 ms (Coil De-Energisation and NO Opening)
Overvoltage CategoryCAT III
Switching Current5 mA (Signalling Circuit)
Tightening Torque0.8 to 1.3 Nm
Electrical ConnectionScrew Clamp Terminals
Rated Breaking Capacity110 A @ 415V, 440V, 220 to 230V, 380 to 400 V, 80 A @ 500V, 70 A @ 660 to 690V
Environmental AttributesMercury Free, Toxic Heavy Metal Free
Rated Making Capacity110 A
Electrical Durability0.18 Mcycles (20 A, AC-1, Less than 440 V), 1.3 Mcycles (9 A, AC-3, Less than 440 V), 1.3 Mcycles (9 A, AC-3e, Less than 440 V)
Watts Loss3W
Max. Operating Watts2.2 kW (at 220 to 230V AC 50/60 Hz), 4 kW (at 380 to 415VAC 50/60 Hz), 4 kW (at 440V AC 50/60 Hz), 4 kW (at 480V AC 50/60 Hz), 4 kW (at 500 to 600V AC 50/60 Hz), 4 kW (at 660 to 690V AC 50/60 Hz)
Mechanical Durability5 Mcycles
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Net Weight0.48 kg
Frequency50/60 Hz
Overall Width3.54 in
Mounting StyleDIN Rail, Plate
Reversing CapabilityReversing
Horsepower @ Three Phase - 600V AC5 hp
Maximum Operating Temperature122 Degrees F
Terminal Connection TypeScrew Clamp Terminals
Horsepower @ Single Phase - 240V AC1 1/2 hp
NEMA Enclosure RatingNo Enclosure
Horsepower @ Three Phase - 208V AC2 hp
Maximum Voltage Rating690V AC
Mechanical Operating Durability5,000,000
Number of Normally Open Main Contacts3
Overall Depth2.24 in
Full Load Current - Inductive9 A
Resistance PropertiesInsulation Resistant
Number of Auxillary Contacts1
Horsepower @ Single Phase - 120V AC1/2 hp
Embedded Surge SuppressorNo
Full Load Current - Resistive20 A
Contactor StyleIEC
Includes Auxiliary ContactsYes
Minimum Operating Temperature-13 Degrees F
Electrical Operating Durability1,300,000, 180,000
Overall Height2.28 in
Coil Voltage24V DC
Horsepower @ Three Phase - 480V AC5 hp
NEMA Enclosure MaterialNot Applicable
Horsepower @ Three Phase - 240V AC3 hp
Auxiliary Contact Composition1 NC
Connections - Terminalsscrew clamp terminals 1 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 1 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 1 0.00 to 0.00 in? (0.34 to 2.5 mm?)flexible with cable end, screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 2 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 2 0.00 to 0.00 in? (0.34 to 1.5 mm?)flexible with cable end
Rated Short Time Withstand Current90 A 122°F (50°C) - 1 s for power circuit, 85 A 122°F (50°C) - 5 s for power circuit, 80 A 122°F (50°C) - 10 s for power circuit, 60 A 122°F (50°C) - 30 s for power circuit, 45 A 122°F (50°C) - 1 min for power circuit, 40 A 122°F (50°C) - 3 min for power circuit, 20 A 122°F (50°C) - Greater than or Equal to 15 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit, 110 A - 100 ms for signalling circuit
Associated Fuse Rating25 A gG at Less than or Equal to 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660
Operating Altitude6561.68 ft (2000 m) without derating
Flame RetardanceV1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102
Minimum Switching Voltage17 V for signalling circuit
Poles Description3P
Maximum Operating Rate3600 cyc/h
Conventional Free Air Thermal Current20 A (at 140°F (60°C)) for power circuit, 10 A (at 122°F (50°C)) for signalling circuit
Power Pole Contact Composition3 NO
Product CertificationsCB Scheme, CCC, UL, CSA, EAC, CE, UKCA
Control Circuit TypeDC standard
Hold-In Power Consumption in W3 W 68°F (20°C)
Heat Dissipation3 W
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Device ApplicationControl
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Product Or Component TypeReversing contactor
Average Impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Rated Insulation VoltagePower circuit 600 V UL 508, Power circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-5-1, Signalling circuit 600 V UL 508, Power circuit 600 V CSA C22.2 No 14, Signalling circuit 600 V CSA C22.2 No 14
IP Degree Of ProtectionIP20 VDE 0106
Ambient Air Temperature For Storage-58 to 176°F (-50 to 80°C)
Non Overlap Distance0.02 in (0.5 mm)
Motor Power KW2.2 kW 220 to 230 V AC 50/60 Hz, 4 kW 380 to 415 V AC 50/60 Hz, 4 kW 440/690 V AC 50/60 Hz
Utilisation CategoryAC-3, AC-3e, AC-4, AC-1
Mounting SupportPlate, Rail
IRMS Rated Making Capacity110 A AC for power circuit conforming to IEC 60947, 110 A AC for signalling circuit conforming to IEC 60947
Mechanical RobustnessShocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27, Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6, Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6, Shocks contactor opened, on X axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Y axis6 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on X axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Y axis10 Gn for 11 ms IEC 60068-2-27
Minimum Switching Current5 mA for signalling circuit
Ambient Air Temperature For Operation-13 to 122°F (-25 to 50°C)
Interlocking TypeMechanical
Protective TreatmentTC IEC 60068, TC DIN 50016
Auxiliary Contacts TypeInstantaneous 1 NC
Rated Operational VoltagePower circuit 690 V AC 50/60 Hz, Signalling circuit Less than or Equal to 690 V AC 50/60 Hz
Rated Operational Current9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit, 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit
Inrush Power in W3 W 68°F (20°C))
Contactor ApplicationMotor control, Resistive load
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#IEC Mini Magnetic Contactor
#3 Poles
#24 V DC
#9 A
#Reversing: Yes
#SCHNEIDER
#Mfr LP2K0901BD
#SCHNEIDER
#GRG1646337
#mfr:LP2K0901BD
#part number:LP2K0901BD
#pn:LP2K0901BD
#part code:LP2K0901BD
#item number:LP2K0901BD
#product code:LP2K0901BD
#manufacturer number:LP2K0901BD
#manufacturers part number:LP2K0901BD
#mfn:LP2K0901BD

Reviews

There are no reviews yet.

Add a review