Item | Miniature IEC Magnetic Contactor |
Full Load Amps-Inductive | 6 A |
Action | Reversing |
Full Load Amps-Resistive | 15 A |
Number of Poles | 3 |
Coil Volts | 120 V AC |
Reversing | Yes |
HP @ 1 Phase - 230V | 1-1/2 |
HP @ 1 Phase - 120V | 1/2 hp |
Height | 3.54 in |
HP @ 1 Phase - 240V | 1 1/2 hp |
Width | 3.54 in |
HP @ 3 Phase - 208V | 1 1/2 hp |
Depth | 1.97 in |
HP @ 3 Phase - 575V | 3 hp |
HP @ 3 Phase - 240V | 1 1/2 hp |
HP @ 3 Phase - 480V | 3 hp |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | 2 NC |
Hz | 50/60 |
Auxiliary Contact Form | 1NC |
Standards | BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660 |
Series | TeSys K |
NEMA Size | Not Applicable |
Watts Loss | 1.3W |
Electrical Connection | Screw Clamp Terminals |
Net Weight | 0.39 kg |
Shock Resistance | 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open) |
Tightening Torque | 0.8 to 1.3 Nm |
Rated Insulation Volts | 600/690V |
Inrush VA | 30 VA |
Overvoltage Category | CAT III |
Electrical Durability | 1.3 Mcycles (6 A, AC-3, Less than 440 V), 1.3 Mcycles (6 A, AC-3e, Less than 440 V) |
Impulse Withstand Voltage | 8 kV |
Fuse Amps | 25 A (Power Circuit), 10 A (Signalling Circuit) |
Rated Breaking Capacity | 110 A @ 415V, 440V, 220 to 230V, 380 to 400 V, 80 A @ 500V, 70 A @ 660 to 690V |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Thermal Amperage | 20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit) |
Application | Motor Control |
Mechanical Durability | 5 Mcycles |
IP Rating | IP20 |
Impedance | 3 mOhm |
Operating Speed | 3600 cycles per hr |
Rated Short-Time Withstand Current | 90 A (at 50°C for 1 s Power Circuit), 85 A (at 50°C for 5 s Power Circuit), 80 A (at 50°C for 10 s Power Circuit), 60 A (at 50°C for 30 s Power Circuit), 45 A (at 50°C for 1 min Power Circuit), 40 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 20 A (at 50°C for 15 min Power Circuit) |
Fire Rating | UL 94 V1, NF F 16-101, NF F 16-102 |
Operating Time | 10 to 20 ms (Coil Energisation and NO Closing), 10 to 20 ms (Coil De-Energisation and NO Opening) |
Switching Current | 5 mA (Signalling Circuit) |
Switching Voltage | 17 V (Signalling Circuit) |
Rated Making Capacity | 110 A |
Mounts On | Plate, Rail |
Rated Voltage | 690V AC |
Control Circuit Voltage Limits | Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C) |
Features | Preassembled with Reversing Power Busbar |
Signalling Circuit Frequency | Less Than 400 Hz |
Hold VA | 4.5 VA |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Max. Operating Watts | 1.5 kW (at 220 to 230V AC 50/60 Hz), 2.2 kW (at 380 to 415VAC 50/60 Hz), 3 kW (at 440V AC 50/60 Hz), 3 kW (at 480V AC 50/60 Hz), 3 kW (at 500 to 600V AC 50/60 Hz), 3 kW (at 660 to 690V AC 50/60 Hz) |
Environmental Attributes | Mercury Free, Toxic Heavy Metal Free |
Working Height | 6561.68 ft |
Horsepower @ Three Phase - 480V AC | 3 hp |
Overall Depth | 2.24 in |
Electrical Operating Durability | 1,300,000 |
Minimum Operating Temperature | -13 Degrees F |
Horsepower @ Three Phase - 240V AC | 1 1/2 hp |
Horsepower @ Three Phase - 600V AC | 3 hp |
Full Load Current - Resistive | 15 A |
Maximum Operating Temperature | 122 Degrees F |
Horsepower @ Single Phase - 120V AC | 1/2 hp |
Embedded Surge Suppressor | No |
Reversing Capability | Reversing |
Resistance Properties | Insulation Resistant |
Number of Auxillary Contacts | 1 |
Overall Width | 3.54 in |
Contactor Style | IEC |
Full Load Current - Inductive | 6 A |
Mechanical Operating Durability | 5,000,000 |
Includes Auxiliary Contacts | Yes |
Number of Normally Open Main Contacts | 3 |
NEMA Enclosure Rating | No Enclosure |
Overall Height | 2.28 in |
Maximum Voltage Rating | 690V AC |
Terminal Connection Type | Screw Clamp Terminals |
Horsepower @ Single Phase - 240V AC | 1 1/2 hp |
NEMA Enclosure Material | Not Applicable |
Mounting Style | DIN Rail, Plate |
Frequency | 50/60 Hz |
Horsepower @ Three Phase - 208V AC | 1 1/2 hp |
Coil Voltage | 120V AC |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
IEC Mini Magnetic Contactor, 3 Poles, 120 V AC, 6 A, Reversing: Yes, SCHNEIDER ELECTRIC, Mfr# LC2K0601G7
$141.61
Free shipping will be applied on orders over $50
Miniature IEC Magnetic Contactor, Auxiliary Contact Form 1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 120V AC, Number of Poles 3, Full Load Current - Inductive 6 A, Full Load Current - Resistive 15 A, Reversing Capability Reversing, Overall Height 2.28 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys K, Number of Auxillary Contacts 1, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$141.61
You must be logged in to post a review.
Reviews