Item - Infrared Thermometer
Infrared Thermometer
Temp. Range
Infrared -27 to 428 Degrees F, Probe -67 to 626 Degrees F
Focus Spot Size and Distance - Infrared
1 in @ 1 in
Temp. Range (F) - Infrared
-27 Degrees to 428 Degrees
Temp. Range (C) - Infrared
-33 Degrees to 220 Degrees
Temp. Accuracy (F) - Infrared
+/-2.0% or +/-4.0 Degrees Whichever is Greater
Temp. Accuracy (C) - Infrared
+/-2.0% or +/-2.0 Degrees Whichever is Greater
Laser Sighting - Infrared
Single Dot
Calibration Certificate Included
No
Data Logging - Instrument
No
Repeatability
IR +/-4 Degrees F or +/-2%, Probe +/-2 Degrees F or +/-1%
Accuracy
+/-4F Degrees / +/-2C Degrees or 2.0% Whichever is Greater, Probe +/-2F Degrees / +/-1C Degrees or +/-1.0%, Whichever is Greater
Operating Temp. Range
32 Degrees to 120 Degrees F
Temp. Range (F)
Infrared -27 Degrees to 428 Degrees F, Probe -67 Degrees to 626 Degrees F
Battery Type
CR2032 Lithium-ion
Focus Spot Size and Distance
1
Temperature Alarm - Thermometer
No
Emissivity
Adjustable 0.10 to 1.00
Spectral Response - Infrared
5.0 to 14.0um
Memory - Instrument
Max., Min
Temp Range (C) - Probe and Other
Probe -55 Degrees to 330 Degrees
Spectral Response
5.0 to 14 uM
Resolution
0.1 Degrees F/0.1 Degrees C and 1 Degrees F/1 Degrees C Above 200 Degrees F/93 Degrees C
Special Features
Lock Function
Temp. Range (C)
Infrared -33 Degrees to 220 Degrees C, Probe -55 Degrees to 330 Degrees C
Includes
Battery, Built In Probe
Manufacturers Warranty Length
1 yr
Temp Range (F) - Probe and Other
Probe -67 Degrees to 626 Degrees
Environmental Applications - Air Conditioners and Heat Pumps
Non-Medical
Features
F/C Switchable, Lock Function for Long Term Monitoring, Low Battery Indicator
Maximum Temperature Measured Degrees C
220 Degrees C
Probe Maximum Temperature Measured Degrees C
330 Degrees C
Emissivity Adjustability
Adjustable
Minimum Operating Temperature Degrees F
32 Degrees F
Battery Chemistry
Lithium Ion
Distance To Spot Ratio
1:1
Minimum Temperature Measured Degrees C
-33 Degrees C
Manufacturer Warranty Length
1 yr
Resolution Degrees C
0.1 Degrees C
Minimum Temperature Measured Degrees F
-27 Degrees F
Calibration Certificate Type
Not Certified
Accuracy Degrees F
+/-1.0% of Reading or +/-2.0 Degrees Whichever is Greater (Probe); +/-2.0% of Reading or +/-4.0 Degrees Whichever is Greater
Maximum Operating Temperature Degrees F
122 Degrees F
Probe Minimum Temperature Measured Degrees C
-55 Degrees C
Number of Batteries Required
1
Secondary Measuring Method
Probe
Maximum Temperature Measured Degrees F
428 Degrees F
Probe Minimum Temperature Measured Degrees F
-67 Degrees F
Testing Functions
Maximum Temperature, Minimum Temperature
Resolution Degrees F
0.1 Degrees F
Minimum Emissivity Setting
0.10
Accuracy Degrees C
+/-2.0% of Reading or +/-2.0 Degrees Whichever is Greater
Digital Display Screen Type
LCD
Probe Maximum Temperature Measured Degrees F
626 Degrees F
Maximum Emissivity Setting
1.00
Country of Origin (subject to change)
China