Item
Electronic Level Sensor
Input Voltage
18 to 30V DC
Temp. Range
32 to 176 Degrees F
Stem Material
316 Stainless Steel
Float Length
Not Applicable
Body Material
Stainless Steel
Float Material
Not Applicable
Product Type
Guided Wave Radar
Storage temperature [°C]
-40...85
Connection
Connector: 1 x M12; coding: A; Contacts: gold-plated
Min. process cycle time [ms]
2.3
Transmission type
COM2 (38,4 kBaud)
Shock resistance
DIN EN 60068-2-27 50 g (11 ms) / 25 g (6 ms) with reference rod 0.5 m
Inactive range I1 / I2 [mm]
30 / 10; (when set to oil and oil based media: 30 / 30)
Special feature
Gold-plated contacts
Dielectric constant of the medium
≥1,8; (for media with a dielectric constant of 1.8...5 (e.g. oils), a coaxial pipe is needed for operation)
Number of inputs and outputs
Number of digital outputs: 2
Recommended media
water; hydrous media; oils; oil-based media
EMC
DIN EN 61000-6-2 DIN EN 61000-6-3 in a closed metal tank DIN EN 61000-6-4 in plastic or open metal tanks
Current consumption [mA]
u003c 30
Max. voltage drop switching output DC [V]
2.5
Reset point rP [mm]
≥10...L-35
Communication interface
IO-Link
Required master port type
A
Measuring principle
guided wave radar
Reverse polarity protection
yes
Type of short-circuit protection
thermal, pulsed
Temperature drift per 10 K
± 0.2 %
Probe length L [mm]
100...1600
MAWP (for applications according to CRN) [bar]
16
Ambient temperature [°C]
-25...60
Materials (wetted parts)
stainless steel (1.4305 / 303); probe connection: stainless steel (1.4435 / 316L); PTFE; FKM; Sealing: NBR reinforced fibre
Vibration resistance
DIN EN 60068-2-6 5 g (10...2000 Hz) / 1 g (5...200 Hz) with reference rod 0.5 m
Power-on delay time [s]
u003c 3
Process connection
G 3/4 external thread
Permanent current rating of switching output DC [mA]
200
Active range A [mm]
L-40; (when set to oil and oil based media: L-60)
UL approval
UL Approval no. H007 File number UL E174191
Operating voltage [V]
18...30 DC
Output signal
switching signal; IO-Link
Set point SP [mm]
≥15...L-30
Output function
normally open / normally closed; (parameterisable)
SDCI standard
IEC 61131-9 CDV
Process temperature [°C]
-25...80; (90 u003c 1 h ; see note under remarks)
Materials
stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; PBT; PC; PEI; TPE-V
Vacuum resistance [mbar]
-1000
Number of digital outputs
2
Short-circuit protection
yes
Nameplate Voltage
18/30V DC
Probe Material
316 Stainless Steel
Operating Pressure - Maximum
232 psi
For Media Type
Oils, Water
Output Wire Configuration
4-Wire
Number of Outputs - Digital
2
Media Temperature - Maximum
176 Degrees F
Mounting Orientation
Vertical
Process temperature [°C]
-25...80; (90 u003c 1 h ; see note under remarks)
Storage temperature [°C]
-40...85
Ambient temperature [°C]
-25...60
Measuring principle
guided wave radar
Country of Origin (subject to change)
Romania