Logic Controller, 0.1A, 16 Outputs, 24VDC, SCHNEIDER ELECTRIC, Mfr# TM221M32TK

$446,99

Free shipping will be applied on orders over $50

Logic Controller, Input Voltage 24V AC/DC, Output Type Relay, 0.1 A Amps, 2 Slots, Number of Inputs 16 Digital, 2 Analog, Number of Outputs 16, Counters 4, Timers Programmable, Yes Clock, 7 Segment LED Display, Port Type Modbus Serial (2xRJ45 - RS232/RS485), SD Card, USB Mini (Prog.), Memory 256 KB, Depth 3 in, Height 4.17 in, Width 2.75 in

9999 in stock

Must order in multiples of 1
Subtotal:
$446.99
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: TM221M32TK
Availability: Ships in 5 days
SKU: GRG0270201 Category:
ItemLogic Controller
Input Voltage24V AC/DC
Output TypeRelay
Amps0.1 A
Number of Outputs16
ClockYes
Display7 Segment LED
Number of Inputs16 Digital, 2 Analog
Memory256 KB
Counters4
Port TypeModbus Serial (2xRJ45 - RS232/RS485), SD Card, USB Mini (Prog.)
Depth3 in
Width2.75 in
TimersProgrammable
Slots2
Height4.17 in
StandardsEN/IEC 60664-1 || EN/IEC 61010-2-201 || EN/IEC 61131-2
Response Time35 µs turn-off, I2 to I5 input || 5 µs turn-on, I0, I1, I6, I7 fast input || 35 µs turn-on, other terminals input || 5 µs turn-off, I0, I1, I6, I7 fast input || 100 µs turn-off, other terminals input || 5 µs turn-on, turn-off, Q0 to Q1 output || 50 µs turn-on, turn-off, Q2 to Q3 output || 300 µs turn-on, turn-off, other terminals output
Surge Withstand2 kV power lines (AC) common mode EN/IEC 61000-4-5 || 2 kV relay output common mode EN/IEC 61000-4-5 || 1 kV I/O common mode EN/IEC 61000-4-5 || 1 kV shielded cable common mode EN/IEC 61000-4-5 || 0.5 kV power lines (DC) differential mode EN/IEC 61000-4-5 || 1 kV power lines (AC) differential mode EN/IEC 61000-4-5 || 1 kV relay output differential mode EN/IEC 61000-4-5 || 0.5 kV power lines (DC) common mode EN/IEC 61000-4-5
Voltage State 1 Guaranteed>= 15 V input
Maximum Size Of Object Areas8000 %MW memory words || 255 %TM timers || 512 %KW constant words || 512 %M memory bits || 255 %C counters
Permitted Overload On Inputs+/- 30 V DC 5 min maximum)analog input || +/- 13 V DC permanent)analog input
Discrete Input Current7 mA discrete input || 5 mA fast input
Maximum Cable Distance Between Devicesshielded cable <10 m fast input || unshielded cable <30 m output || unshielded cable <30 m digital input || unshielded cable <1 m analog input || shielded cable <3 m fast output
MarkingCE
Function AvailablePLS || PWM || frequency generator
Discrete Output Voltage24 V DC
Integrated Connection TypeUSB port mini B USB 2.0 || non isolated serial link serial 1 RJ45 RS485 || non isolated serial link serial 2 RJ45 RS232/RS485
Resistance To Magnetic Fields30 A/m 50/60 Hz EN/IEC 61000-4-8
Discrete Input Voltage24 V
Maximum Voltage Drop<1 V
Insulationbetween input and internal logic 500 V AC || between fast input and internal logic 500 V AC || non-insulated between inputs || between output and internal logic 500 V AC || non-insulated between analogue input and internal logic || non-insulated between analogue inputs
Counting Input Number4 fast input (HSC mode) 100 kHz 32 bits
Mechanical Durability20000000 cycles transistor output
Execution Time Per Instruction0.2 µs Boolean
Protection Typeshort-circuit and overload protection with automatic reset || short-circuit protection on output || overload and short-circuit protection 0.2 A
Immunity To Microbreaks10 ms
Positioning FunctionsPTO 2 pulse/direction 100 kHz) || PTO 1 CW/CCW 100 kHz)
Lsb Value10 mV
Mounting Supporttop hat type TH35-15 rail IEC 60715 || top hat type TH35-7.5 rail IEC 60715 || plate or panel with fixing kit
Discrete Output Typetransistor
Maximum Power Consumption In W22.3 W 24 V with max number of I/O expansion module) || 3.5 W 24 V without I/O expansion module)
[Us] Rated Supply Voltage24 V DC
Relative Humidity10-95 %, without condensation in operation) || 10-95 %, without condensation in storage)
Configurable Filtering Time0 ms input || 3 ms input || 12 ms input
Supply Voltage Limits20.4-28.8 V
Regulation Loopadjustable PID regulator up to 14 simultaneous loops
Pollution Degree<= 2
Battery TypeBR2032 lithium non-rechargeable 4 year(s)
Conversion Time1 ms per channel + 1 controller cycle time analog input
Discrete Input Logicsink or source (positive/negative)
Operating Altitude0 to 6561.68 ft (0 to 2000 m)
Clock Drift<= 30 s/month 25-25 °C
Storage Altitude0-3000 m
Analogue Input Number2 0 to 10 V
Backup Time1 year 25 °C by interruption of power supply)
Resistance To Fast Transients2 kV EN/IEC 61000-4-4 power lines) || 2 kV EN/IEC 61000-4-4 relay output) || 1 kV EN/IEC 61000-4-4 I/O) || 1 kV EN/IEC 61000-4-4 Ethernet line) || 1 kV EN/IEC 61000-4-4 serial link)
Maximum Number Of I/O Expansion Module7 (local I/O-Architecture) || 14 (remote I/O-Architecture)
Realtime Clockwith
Discrete Input Voltage TypeDC
Data Backed Up256 kB built-in flash memory backup of application and data
Product Or Component Typelogic controller
Ambient Air Temperature For Storage-25-70 °C
Exct Time For Event Task60 µs response time
Electrical Connectionterminal block, 3 for connecting the 24 V DC power supply || connector, 4 for analogue inputs || mini B USB 2.0 connector for a programming terminal || HE-10 connector, 20 for inputs || HE-10 connector, 20 for outputs
Discrete Input Number16 , discrete input 4 fast input IEC 61131-2 Type 1
Output Frequency100 kHz fast output (PWM/PLS mode) Q0 to Q1 || 5 kHz output Q2 to Q3 || 0.1 kHz output Q4 to Q15
Transmission Rate1.2 to 115.2 kbit/s (115.2 kbit/s by default) 15-15 m RS485 || 1.2 to 115.2 kbit/s (115.2 kbit/s by default) 3-3 m RS232 || 480 Mbit/s USB
Resistance To Electrostatic Discharge8 kV in air EN/IEC 61000-4-2 || 4 kV on contact EN/IEC 61000-4-2
Power Supply Output Current0.52-0.52 A 5 V expansion bus || 0.48-0.48 A 24 V expansion bus
Supplyserial 1)serial link supply 5 V, <200 mA
Discrete Output Logicpositive logic (source)
Discrete Output Current0.1 A
Maximum Leakage Current0.1 mA transistor output
Input Impedance3.4 kOhm discrete input || 100 kOhm analog input || 4.9 kOhm fast input
Vibration Resistance3.5 mm 5-8.4 Hz symmetrical rail || 3.5 mm 5-8.4 Hz panel mounting || 1 gn 8.4-150 Hz symmetrical rail || 1 gn 8.4-150 Hz panel mounting
Analogue Input Resolution10 bits
Inrush Current35 A
Discrete I/O Number32
Absolute Accuracy Error+/- 1 % of full scale analog input
Ip Degree Of ProtectionIP20 with protective cover in place
Voltage State 0 Guaranteed<= 5 V input
Reset Time1 s automatic reset
Product CertificationsCSA || IACS E10 || cULus || LR || RCM || DNV-GL || EAC || ABS
Application Structure1 configurable freewheeling/cyclic master task || 1 cyclic auxiliary task || 8 interrupt tasks
Maximum Tungsten Load<2.4 W output and fast output
Electromagnetic Emissionconducted emissions 79 dB??V/m QP/66 dB??V/m AV power lines (AC))0.15-0.5 MHz EN/IEC 55011 || conducted emissions 73 dB??V/m QP/60 dB??V/m AV power lines (AC))0.5-300 MHz EN/IEC 55011 || conducted emissions 120 to 69 dBµV/m QP power lines)10-150 kHz EN/IEC 55011 || conducted emissions 63 dB??V/m QP power lines)1.5-30 MHz EN/IEC 55011 || radiated emissions 40 dB??V/m QP class A 10 m)30-230 MHz EN/IEC 55011 || conducted emissions 79 to 63 dB??V/m QP power lines)150-1500 kHz EN/IEC 55011 || radiated emissions 47 dB??V/m QP class A 10 m)200-1000 MHz EN/IEC 55011
Ambient Air Temperature For Operation-10-55 °C horizontal installation) || -10-35 °C vertical installation)
Memory capacity256 kB user application and data RAM 10000 instructions || 256 kB internal variables RAM
Control Signal Typesingle phase || A/B || pulse/direction
Shock Resistance147 m/s? 11 ms
Execution Time For 1 Kinstruction0.3 ms event and periodic task || 0.7 ms other instruction
Local Signallingfor PWR 1 LED (green) || for RUN 1 LED (green) || for module error (ERR) 1 LED (red) || for SD card access (SD) 1 LED (green) || for BAT 1 LED (red) || for SL1 1 LED (green) || for SL2 1 LED (green) || for I/O state 1 LED per channel (green)
Communication ServiceModbus master || Modbus slave
Environmental Characteristicordinary and hazardous location
Data Storage Equipment2 GB SD card optional)
Resistance To Electromagnetic Fields10 V/m 80 MHz to 1 GHz EN/IEC 61000-4-3 || 3 V/m 1.4 GHz to 2 GHz EN/IEC 61000-4-3 || 1 V/m 2 to 2.7 GHz EN/IEC 61000-4-3
Communication Port ProtocolUSB port USB - SoMachine-Network || non isolated serial link Modbus master/slave - RTU/ASCII or SoMachine-Network
Resistance To Conducted Disturbances10 V 0.15 to 80 MHz EN/IEC 61000-4-6 || 3 V 0.1 to 80 MHz Marine specification (LR, ABS, DNV, GL) || 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) Marine specification (LR, ABS, DNV, GL)
Discrete Output Number16 transistor 2 fast output
Maximum Current Per Output Common1.6 A
Execution Time For 1 K instruction0.3 ms event and periodic task, 0.7 ms other instruction
Time For Event Task60 µs response time
Counter FunctionSingle phase, A/B, Pulse/direction
Country of Origin (subject to change)Taiwan, Province of China
Package Quantity1
TAGS:
#Logic Controller
#0.1A
#16 Outputs
#24VDC
#SCHNEIDER ELECTRIC
#Mfr TM221M32TK
#SCHNEIDER ELECTRIC
#GRG0270201
#mfr:TM221M32TK
#part number:TM221M32TK
#pn:TM221M32TK
#part code:TM221M32TK
#item number:TM221M32TK
#product code:TM221M32TK
#manufacturer number:TM221M32TK
#manufacturers part number:TM221M32TK
#mfn:TM221M32TK

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!