Item | Logic Relay |
Input Voltage | 24V AC/DC |
Output Type | Relay |
Amps | 8 A |
Number of Outputs | 10 |
Clock | Yes |
Display | LCD |
Number of Inputs | 16 |
Height | 4.24 in |
Counters | 16 |
Width | 4.91 in |
Depth | 2.34 in |
Timers | 16 |
Response Time | 10 ms from state 0 to state 1)relay output || 5 ms from state 1 to state 0)relay output |
Standards | EN/IEC 61000-4-2 level 3 || EN/IEC 61000-4-5 || EN/IEC 61000-4-6 level 3 || EN/IEC 61000-4-11 || EN/IEC 61000-4-3 || EN/IEC 60068-2-27 Ea || EN/IEC 61000-4-12 || EN/IEC 60068-2-6 Fc || EN/IEC 61000-4-4 level 3 |
Switching Capacity In Ma | >= 10 mA 12 V relay output) |
Product Or Component Type | modular smart relay |
Input Impedance | 12 kOhm IB to IG used as analogue input circuit || 12 kOhm IB to IG used as discrete input circuit || 7.4 kOhm I1 to IA and IH to IR discrete input circuit |
Current State 1 Guaranteed | >= 1.2 mA IB to IG used as discrete input circuit) || >= 2.2 mA I1 to IA and IH to IR discrete input circuit) |
Immunity To Microbreaks | 1 ms |
Power Dissipation In W | 10 W with extensions || 6 W without extension |
Maximum Supply Current | 190 mA without extension) || 300 mA with extensions) |
Analogue Input Type | common mode |
Disturbance Radiated/Conducted | class B EN 55022-11 group 1 |
Counting Frequency | 1 kHz discrete input |
Operating Distance | 10 m between stations, with screened cable (sensor not isolated) analogue input circuit |
Analogue Input Resolution | 8 bits |
Product Certifications | GL || C-tick || CSA || UL || GOST |
Temperature Probe Type | NTC 10k 25 °C || NTC 1000k 25 °C || KTY81 210/220/221/222/250 || Pt 500 |
Ambient Air Temperature For Storage | -40-70 °C |
Analogue Input Range | 0 to 10 V || 0 to 24 V |
Supply Voltage Limits | 19.2-30 V |
[Uimp] Rated Impulse Withstand Voltage | 4 kV EN/IEC 60947-1 and EN/IEC 60664-1 |
Conversion Error | +/- 5 % 25 °C analogue input circuit || +/- 6.2 % 55 °C analogue input circuit |
Discrete Input Number | 16 EN/IEC 61131-2 type 1 |
Mechanical Durability | 10000000 cycles relay output |
Discrete Input Voltage | 24 V DC |
Maximum Altitude Transport | 3048 m |
Connections - Terminals | screw terminals, 1 x 0.2 to 1 x 2.5 mm? AWG 25 to AWG 14) semi-solid || screw terminals, 1 x 0.2 to 1 x 2.5 mm? AWG 25 to AWG 14) solid || screw terminals, 1 x 0.25 to 1 x 2.5 mm? AWG 24 to AWG 14) flexible with cable end || screw terminals, 2 x 0.2 to 2 x 1.5 mm? AWG 24 to AWG 16) solid || screw terminals, 2 x 0.25 to 2 x 0.75 mm? AWG 24 to AWG 18) flexible with cable end |
Analogue Input Number | 6 |
Operating Rate In Hz | 0.1 Hz at Ie)relay output || 10 Hz no load)relay output |
Discrete Input Current | 4 mA |
Lsb Value | 39 mV analogue input circuit |
Operating Altitude | 6561.68 ft (2000 m) |
Number Or Control Scheme Lines | 0-500 FBD || 0-240 ladder |
Voltage State 0 Guaranteed | <= 5 V I1 to IA and IH to IR discrete input circuit || <= 5 V IB to IG used as discrete input circuit |
Voltage State 1 Guaranteed | >= 15 V I1 to IA and IH to IR discrete input circuit || >= 15 V IB to IG used as discrete input circuit |
Contacts Type And Composition | NO relay output |
Relative Humidity | 95-95 % without condensation or dripping water |
Ip Degree Of Protection | IP20 IEC 60529 terminal block) || IP40 IEC 60529 front panel) |
Repeat Accuracy | +/- 2 % 55 °C analogue input circuit |
Discrete Input Type | resistive |
Ambient Air Temperature For Operation | -20-40 °C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2 || -20-55 °C IEC 60068-2-1 and IEC 60068-2-2 |
Reverse Polarity Protection | with |
Output Thermal Current | 5 A for 2 outputs relay output || 8 A for 8 outputs relay output |
Environmental Characteristic | EMC directive EN/IEC 61000-6-2 || EMC directive EN/IEC 61000-6-3 || EMC directive EN/IEC 61000-6-4 || EMC directive EN/IEC 61131-2 zone B || low voltage directive EN/IEC 61131-2 |
Cycle Time | 6-90 ms |
Maximum Permissible Voltage | 30 V analogue input circuit |
Input Compatibility | 3-wire proximity sensors PNP discrete input |
Output Voltage Limits | 24 to 250 V AC relay output) || 5 to 30 V DC relay output) |
Overvoltage Category | III EN/IEC 60664-1 |
Current State 0 Guaranteed | <= 0.5 mA IB to IG used as discrete input circuit) || <= 0.75 mA I1 to IA and IH to IR discrete input circuit) |
Clock Drift | 12 min/year 0-55 °C || 6 s/month 25-25 °C |
[Us] Rated Supply Voltage | 24 V |
Checks | program memory on each power up |
Conversion Time | smart relay cycle time analogue input circuit |
Tightening Torque | 0.5 N.m |
Backup Time | 10 years 25 °C |
Local Display | with |
Electrical Durability | AC-12 500000 cycles 230 V, 1.5 A relay output EN/IEC 60947-5-1 || AC-15 500000 cycles 230 V, 0.9 A relay output EN/IEC 60947-5-1 || DC-12 500000 cycles 24 V, 1.5 A relay output EN/IEC 60947-5-1 || DC-13 500000 cycles 24 V, 0.6 A relay output EN/IEC 60947-5-1 |
Pollution Degree | 2 EN/IEC 61131-2 |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
Logic Relay, 24VDC, With Display, SCHNEIDER ELECTRIC, Mfr# SR3B261BD
$415.15
Free shipping will be applied on orders over $50
Logic Relay, Input Voltage 24V AC/DC, Output Type Relay, 8 A Amps, Number of Inputs 16, Number of Outputs 10, Counters 16, Timers 16, Yes Clock, LCD Display, Depth 2.34 in, Height 4.24 in, Width 4.91 in
9999 in stock
Must order in multiples of 1
Subtotal:
$415.15
You must be logged in to post a review.
Reviews
There are no reviews yet.