Enclosure NEMA Rating
No Enclosure
Overload Relay Amp Setting
0.16 to 0.25A
Description/Special Features
Screw Clamp Terminals, Single Unit
Phase Loss Sensitivity
Yes
Standards
ATEX Compliant, BV, CCC, CSA, DNV-GL, EAC, EN/IEC 60947-2, EN/IEC 60947-4, LROS, RINA, UKCA, UL Listed
Trip Unit Technology
thermal-magnetic
Mechanical Robustness
shocks 30 Gn for 11 ms || vibrations 5 Gn, 5...150 Hz
Fixing Mode
35 mm symmetrical DIN rail clipped || panel screwed with adaptor plate)
Utilisation Category
category A IEC 60947-2 || AC-3 IEC 60947-4-1
[Ui] Rated Insulation Voltage
690 V AC 50/60 Hz IEC 60947-2
Suitability For Isolation
yes IEC 60947-1§ 7-1-6
Product Name
TeSys GV2 || TeSys Deca
Ik Degree Of Protection
IK04
Magnetic Tripping Current
2.4-2.4 A
[Ith] Conventional Free Air Thermal Current
0.25 A IEC 60947-4-1
Ambient Air Temperature For Operation
-20-60°C
Breaking Capacity
100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ics] Rated Service Short-Circuit Breaking Capacity
100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 100 % 400/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 100 % 690 V AC 50/60 Hz IEC 60947-2
Operating Altitude
6561.68 ft (2000 m)
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60947-2
Ip Degree Of Protection
IP20 IEC 60529
Electrical Durability
100000 cycles AC-3 415 V In
Network Frequency
50/60 Hz IEC 60947-4-1
Tightening Torque
1.7 N.m screw clamp terminal
Thermal Protection Adjustment Range
0.16-0.25 A IEC 60947-4-1
Fire Resistance
960°C IEC 60695-2-11
Ambient Air Temperature For Storage
-40-80°C
Device Application
motor protection
Rated Duty
continuous IEC 60947-4-1
Motor Power Kw
0.06-0.06 kW 400/415 V AC 50/60 Hz
Product Certifications
CCC || UL || CSA || EAC || ATEX || LROS (Lloyds register of shipping) || BV || RINA || DNV-GL || UKCA
Power Dissipation Per Pole
2.5 W
Climatic Withstand
IACS E10
Product Or Component Type
motor circuit breaker
Phase Failure Sensitivity
yes IEC 60947-4-1
[Ue] Rated Operational Voltage
690 V AC 50/60 Hz IEC 60947-2
Mechanical Durability
100000 cycles
Maximum Operating Temperature
140 Degrees F
Maximum Overload Relay Current Setting
0.25 A
Resistance Properties
Fire Resistant
Status Indicator
No Indicator
Maximum Voltage Rating
600V AC
Overload Protection Type
Thermal
Terminal Connection Type
Screw Clamp Terminals
Minimum Overload Relay Current Setting
0.16 A
Minimum Operating Temperature
-4 Degrees F
NEMA Enclosure Rating
No Enclosure
Electrical Operating Durability
100,000
Mechanical Operating Durability
100,000
Country of Origin (subject to change)
Thailand