Enclosure NEMA Rating
3R, 4
Number of Required Thermals
Not Applicable
HP @ 1 Phase - 120V
1/2 hp
HP @ 3 Phase - 460-575V
5 hp
Description/Special Features
Thermal-Magnetic Trip Unit Technology
HP @ 3 Phase - 575V
7 1/2 hp
Standards
cUL, EN/IEC 60947-2, EN/IEC 60947-4-1, RoHS, UL 60947-4-1
Phase Loss Sensitivity
Yes
HP @ 1 Phase - 230V
1 1/2 hp
Trip Unit Technology
thermal-magnetic
Ik Degree Of Protection
IK04
Breaking Capacity
100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 10 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 3 kA Icu 690 V AC 50/60 Hz IEC 60947-2
Phase Failure Sensitivity
yes IEC 60947-4-1
Connections - Terminals
screw clamp terminals 1-6 mm² - solid || screw clamp terminals 1.5-6 mm² - flexible without cable end || screw clamp terminals 1-4 mm² - flexible with cable end || screw clamp terminals AWG 18 to AWG 8)
Electrical Durability
100000 cycles AC-3 440 V
Product Name
Easy TeSys GP2E
Power Dissipation Per Pole
2.5 W
Fire Resistance
960°C IEC 60695-2-1
[Ui] Rated Insulation Voltage
690 V AC 50/60 Hz IEC 60947-2
Operating Position
any position
[Ics] Rated Service Short-Circuit Breaking Capacity
100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 100 % 400/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 75 % 690 V AC IEC 60947-2
Product Or Component Type
motor controller
Maximum Operating Rate
25 cyc/h
Rated Duty
continuous IEC 60947-4-1
Network Frequency
50/60 Hz IEC 60947-4-1
Mechanical Durability
100000 cycles
Suitability For Isolation
yes IEC 60947-1
[Ue] Rated Operational Voltage
690 V AC 50/60 Hz IEC 60947-2
Ip Degree Of Protection
IP20 IEC 60529
Tightening Torque
1.7 N.m screw clamp terminals
Magnetic Tripping Current
138-138 A
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60947-2
Product Certifications
cUL
Fixing Mode
35 mm symmetrical DIN rail clipped || panel screwed with adaptor plate)
[Ith] Conventional Free Air Thermal Current
10 A IEC 60947-4-1
Utilisation Category
AC-3 IEC 60947-4-1 || category A IEC 60947-2
Operating Altitude
6561.68 ft (2000 m)
Ambient Air Temperature For Storage
-40-80°C
Ambient Air Temperature For Operation
-20-60°C
Horsepower @ Three Phase - 480V AC
5 hp
Horsepower @ Three Phase - 240V AC
3 hp
Minimum Overload Relay Current Setting
6 A
Minimum Operating Temperature
-4 Degrees F
Maximum Operating Temperature
140 Degrees F
Maximum Voltage Rating
690V AC
Overload Protection Type
Thermal
Horsepower @ Single Phase - 240V AC
1 1/2 hp
Mounting Hole Distance - Width
1.38 in
Mounting Hole Distance - Height
1.97 in
Electrical Operating Durability
100,000
Horsepower @ Single Phase - 120V AC
1/2 hp
Mechanical Operating Durability
100,000
NEMA Enclosure Rating
No Enclosure
Horsepower @ Three Phase - 600V AC
7 1/2 hp
Resistance Properties
Fire Resistant
Maximum Overload Relay Current Setting
10 A
Horsepower @ Three Phase - 208V AC
2 hp
Terminal Connection Type
Screw Clamp Terminals
Country of Origin (subject to change)
Thailand