Motor Manager, CANopen, 24VDC, 0.40-8A, SCHNEIDER ELECTRIC, Mfr# LTMR08CBD

$832,99

Free shipping will be applied on orders over $50

Motor Management System, Number of Normally Open Contacts 4, Number of Normally Closed Contacts 1, Number of Contacts Included 5, Operating Voltage 690V AC, Control Voltage 24V DC, Interface CANopen, Compatible with Series TeSys T, Overall Width 3.58 in, Standards ATEX Compliant, CCC, CSA C22.2 No 14, EN 60947-4-1, IACSE10, IEC 60947-4-1, nABS, nBV, nC-tick, nCSA, nDNV, nEAC, nGL, nKERI, nLROS, nNOM, nRINA, nRMRoS, nUL, UL 508, Overall Height 2.4 in, Overall Depth 4.82 in

Out of stock

Brand Name: SCHNEIDER ELECTRIC
Mfr #: LTMR08CBD
Availability: Ships in 1 days
SKU: GRG1568716 Category:
ItemMotor Management System
Current Range0.40 to 8A
Control Voltage24V DC
Width3.58 in
InterfaceCANopen
Operating Voltage690V AC
Height2.4 in
Depth4.82 in
For Use WithShort Circuit Protection And A Contactor
StandardsATEX Compliant, CCC, CSA C22.2 No 14, EN 60947-4-1, IACSE10, IEC 60947-4-1, nABS, nBV, nC-tick, nCSA, nDNV, nEAC, nGL, nKERI, nLROS, nNOM, nRINA, nRMRoS, nUL, UL 508
Electromagnetic Compatibilityelectrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 || radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 || fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 || voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 || conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 || temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 || temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Maximum Operating Frequency2 Hz
Protective Treatment12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068
Ambient Air Temperature For Operation-20-60°C
RangeTeSys
Compatibility CodeLTMR
Pollution Degree3
Network And Machine Diagnosis Typetrip context information || remaining operating time before overload tripping || starting current and time || event recording || motor control command recording || running hours counter/operating time || waiting time after overload tripping || trip history information || phase fault and earth fault trip counters || fault recording
Logic Input Number6
Tightening Torquecontrol circuit 0.5-0.6 N.m flat 3 mm
Overvoltage CategoryIII
Mechanical Robustnessvibrations mounted on symmetrical rail1 Gn, 5 to 300 Hz EN/IEC 60068-2-6 || vibrations plate mounted4 Gn, 5 to 300 Hz EN/IEC 60068-2-6 || shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27
Device Applicationequipment monitoring and control
Contacts Type And Composition1 NO + 1 NC fault signal || 3 NO
Measurement Accuracy5 to 15 % earth fault current internal measurement || 1 % voltage 100 to 830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 1 % current || 5 % active and reactive power
Connections - Terminalscontrol circuit connector 1 0.25-2.5 mm? AWG 24 to AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mm? AWG 24 to AWG 14)solid without cable end || control circuit connector 2 0.2-1 mm? AWG 24 to AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mm? AWG 24 to AWG 14)solid without cable end
Current State 0 Guaranteedlogic input < 5 V <= 15 mA 5 ms
Device Short NameLTMR
Metering Typeaverage current Iavg || phase current I1, I2, I3 RMS || temperature || earth-fault current || imbalance current
Ambient Air Temperature For Storage-40-80°C
[Uimp] Rated Impulse Withstand Voltage6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1 || 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1
Supply Voltage Limits20.4-26.24 V DC
Current State 1 Guaranteedlogic input < 15 V 2 to 15 mA 15 ms
Measurement Current0.4-8 A
Current Consumption56 to 127 mA
Input Current7 mA
[Us] Rated Supply Voltage24 V DC
Operating Altitude<= 6561.68 ft (2000 m) without derating
Fire Resistance650°C EN/IEC 60695-2-12 || 960°C UL 94
Connection Pitch5.08 mm
Maximum Operating Rate1800 cyc/h
Communication Port ProtocolCANopen
Bus TypeCANopen ISO 1198 1 to 127 10 to 1000 kbit/s, SUB-D 9 4 twisted shielded pairs cable || CANopen ISO 1198 1 to 127 10 to 1000 kbit/s, terminal block 4 twisted shielded pairs cable
Short-Circuit Withstand100 kA conforming to EN/IEC 60947-4-1
Product CertificationsATEX || C-tick || EAC || LROS (Lloyds register of shipping) || NOM || BV || RINA || KERI || ABS || UL || CSA || DNV || RMRoS || GL || CCC
Ip Degree Of ProtectionIP20
Product Or Component Typemotor controller
Protection Typeoverload (long time) || phase failure || load fluctuation || phase imbalance || reverse polarity protection || thermal protection || thermal overload protection || earth-leakage protection || power factor variation || overload || locked rotor
Load Current5 A 250 V AC logic output || 5 A 30 V DC logic output
[Ui] Rated Insulation Voltage690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508
Associated Fuse Rating4 A gG output || 0.5 A gG control circuit
Permissible Power480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
Product NameTeSys T
Web Servicesweb server
Maximum Current Rating8 A
Number of Normally Open Contacts4
Minimum Current Rating0.4 A
Overall Width3.58 in
Overall Depth4.82 in
Overall Height2.4 in
Compatible with SeriesTeSys T
Number of Normally Closed Contacts1
Number of Contacts Included5
Contact Type and Composition1 NO + 1 NC fault signal, 3 NO
Rated Insulation Voltage690 V EN/IEC 60947-1, 690 V CSA C22.2 No 14, 690 V UL 508
Rated Impulse Withstand Voltage6 kV current or voltage measurement circuit EN/IEC 60947-4-1, 0.8 kV communication circuit EN/IEC 60947-4-1, 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1
Country of Origin (subject to change)China
Package Quantity1
TAGS:
#Motor Manager
#CANopen
#24VDC
#0.40-8A
#SCHNEIDER ELECTRIC
#Mfr LTMR08CBD
#SCHNEIDER ELECTRIC
#GRG1568716
#mfr:LTMR08CBD
#part number:LTMR08CBD
#pn:LTMR08CBD
#part code:LTMR08CBD
#item number:LTMR08CBD
#product code:LTMR08CBD
#manufacturer number:LTMR08CBD
#manufacturers part number:LTMR08CBD
#mfn:LTMR08CBD

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!