Item | Motor Management System |
Current Range | 0.40 to 8A |
Control Voltage | 24V DC |
Width | 3.58 in |
Interface | CANopen |
Operating Voltage | 690V AC |
Height | 2.4 in |
Depth | 4.82 in |
For Use With | Short Circuit Protection And A Contactor |
Standards | ATEX Compliant, CCC, CSA C22.2 No 14, EN 60947-4-1, IACSE10, IEC 60947-4-1, nABS, nBV, nC-tick, nCSA, nDNV, nEAC, nGL, nKERI, nLROS, nNOM, nRINA, nRMRoS, nUL, UL 508 |
Electromagnetic Compatibility | electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 || radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 || fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 || voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 || conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 || temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 || temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5 |
Maximum Operating Frequency | 2 Hz |
Protective Treatment | 12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068 |
Ambient Air Temperature For Operation | -20-60°C |
Range | TeSys |
Compatibility Code | LTMR |
Pollution Degree | 3 |
Network And Machine Diagnosis Type | trip context information || remaining operating time before overload tripping || starting current and time || event recording || motor control command recording || running hours counter/operating time || waiting time after overload tripping || trip history information || phase fault and earth fault trip counters || fault recording |
Logic Input Number | 6 |
Tightening Torque | control circuit 0.5-0.6 N.m flat 3 mm |
Overvoltage Category | III |
Mechanical Robustness | vibrations mounted on symmetrical rail1 Gn, 5 to 300 Hz EN/IEC 60068-2-6 || vibrations plate mounted4 Gn, 5 to 300 Hz EN/IEC 60068-2-6 || shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27 |
Device Application | equipment monitoring and control |
Contacts Type And Composition | 1 NO + 1 NC fault signal || 3 NO |
Measurement Accuracy | 5 to 15 % earth fault current internal measurement || 1 % voltage 100 to 830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 1 % current || 5 % active and reactive power |
Connections - Terminals | control circuit connector 1 0.25-2.5 mm? AWG 24 to AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mm? AWG 24 to AWG 14)solid without cable end || control circuit connector 2 0.2-1 mm? AWG 24 to AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mm? AWG 24 to AWG 14)solid without cable end |
Current State 0 Guaranteed | logic input < 5 V <= 15 mA 5 ms |
Device Short Name | LTMR |
Metering Type | average current Iavg || phase current I1, I2, I3 RMS || temperature || earth-fault current || imbalance current |
Ambient Air Temperature For Storage | -40-80°C |
[Uimp] Rated Impulse Withstand Voltage | 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1 || 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1 |
Supply Voltage Limits | 20.4-26.24 V DC |
Current State 1 Guaranteed | logic input < 15 V 2 to 15 mA 15 ms |
Measurement Current | 0.4-8 A |
Current Consumption | 56 to 127 mA |
Input Current | 7 mA |
[Us] Rated Supply Voltage | 24 V DC |
Operating Altitude | <= 6561.68 ft (2000 m) without derating |
Fire Resistance | 650°C EN/IEC 60695-2-12 || 960°C UL 94 |
Connection Pitch | 5.08 mm |
Maximum Operating Rate | 1800 cyc/h |
Communication Port Protocol | CANopen |
Bus Type | CANopen ISO 1198 1 to 127 10 to 1000 kbit/s, SUB-D 9 4 twisted shielded pairs cable || CANopen ISO 1198 1 to 127 10 to 1000 kbit/s, terminal block 4 twisted shielded pairs cable |
Short-Circuit Withstand | 100 kA conforming to EN/IEC 60947-4-1 |
Product Certifications | ATEX || C-tick || EAC || LROS (Lloyds register of shipping) || NOM || BV || RINA || KERI || ABS || UL || CSA || DNV || RMRoS || GL || CCC |
Ip Degree Of Protection | IP20 |
Product Or Component Type | motor controller |
Protection Type | overload (long time) || phase failure || load fluctuation || phase imbalance || reverse polarity protection || thermal protection || thermal overload protection || earth-leakage protection || power factor variation || overload || locked rotor |
Load Current | 5 A 250 V AC logic output || 5 A 30 V DC logic output |
[Ui] Rated Insulation Voltage | 690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508 |
Associated Fuse Rating | 4 A gG output || 0.5 A gG control circuit |
Permissible Power | 480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output) |
Product Name | TeSys T |
Web Services | web server |
Maximum Current Rating | 8 A |
Number of Normally Open Contacts | 4 |
Minimum Current Rating | 0.4 A |
Overall Width | 3.58 in |
Overall Depth | 4.82 in |
Overall Height | 2.4 in |
Compatible with Series | TeSys T |
Number of Normally Closed Contacts | 1 |
Number of Contacts Included | 5 |
Contact Type and Composition | 1 NO + 1 NC fault signal, 3 NO |
Rated Insulation Voltage | 690 V EN/IEC 60947-1, 690 V CSA C22.2 No 14, 690 V UL 508 |
Rated Impulse Withstand Voltage | 6 kV current or voltage measurement circuit EN/IEC 60947-4-1, 0.8 kV communication circuit EN/IEC 60947-4-1, 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1 |
Country of Origin (subject to change) | China |
Package Quantity | 1 |
Motor Manager, CANopen, 24VDC, 0.40-8A, SCHNEIDER ELECTRIC, Mfr# LTMR08CBD
$832,99
Free shipping will be applied on orders over $50
Motor Management System, Number of Normally Open Contacts 4, Number of Normally Closed Contacts 1, Number of Contacts Included 5, Operating Voltage 690V AC, Control Voltage 24V DC, Interface CANopen, Compatible with Series TeSys T, Overall Width 3.58 in, Standards ATEX Compliant, CCC, CSA C22.2 No 14, EN 60947-4-1, IACSE10, IEC 60947-4-1, nABS, nBV, nC-tick, nCSA, nDNV, nEAC, nGL, nKERI, nLROS, nNOM, nRINA, nRMRoS, nUL, UL 508, Overall Height 2.4 in, Overall Depth 4.82 in
Out of stock
You must be logged in to post a review.
Reviews
There are no reviews yet.