| Property | Value |
|---|---|
| Item | Motor Management System |
| Current Range | 0.40 to 8A |
| Control Voltage | 100-240V AC |
| Width | 3.58 in |
| Interface | DeviceNet |
| Operating Voltage | 690V AC |
| Height | 2.4 in |
| Depth | 4.82 in |
| Standards | CSA C22.2 No 14, EN 60947-4-1, IACSE10, IEC 60947-4-1, KERI, nABS, nATEX, nBV, nC-tick, nCCC, nCSA, nDNV, nEAC, nGL, nLROS, nNOM, nRINA, nRMRoS, nUL, UL 508 |
| For Use With | Short Circuit Protection And A Contactor |
| [Ui] Rated Insulation Voltage | 690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508 |
| Pollution Degree | 3 |
| Permissible Power | 480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output) |
| Ambient Air Temperature For Storage | -40-80ΓΒ°C |
| Device Short Name | LTMR |
| Device Application | equipment monitoring and control |
| Ambient Air Temperature For Operation | -20-60ΓΒ°C |
| [Us] Rated Supply Voltage | 100 to 240 V AC 50/60 Hz |
| Input Current | 3.1 mA 100 V || 7.5 mA 240 V |
| Connections - Terminals | control circuit connector 1 0.25-2.5 mmΓΒ² AWG 24 to AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mmΓΒ² AWG 24 to AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mmΓΒ² AWG 24 to AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mmΓΒ² AWG 24 to AWG 14)solid without cable end || control circuit connector 2 0.2-1 mmΓΒ² AWG 24 to AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mmΓΒ² AWG 24 to AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mmΓΒ² AWG 24 to AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mmΓΒ² AWG 24 to AWG 14)solid without cable end |
| Electromagnetic Compatibility | electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 || fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 || voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 || conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 || temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 || temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5 |
| Communication Port Protocol | DeviceNet |
| Measurement Current | 0.4-8 A |
| Tightening Torque | control circuit 0.5-0.6 N.m flat 3 mm |
| Overvoltage Category | III |
| Protective Treatment | 12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068 |
| Mechanical Robustness | vibrations mounted on symmetrical rail1 Gn, 5 to 300 Hz EN/IEC 60068-2-6 || vibrations plate mounted4 Gn, 5 to 300 Hz EN/IEC 60068-2-6 || shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27 |
| Supply Voltage Limits | 93.5-264 V AC |
| Metering Type | imbalance current || earth-fault current || average current Iavg || temperature || phase current I1, I2, I3 RMS |
| Maximum Operating Frequency | 2 Hz |
| Compatibility Code | LTMR |
| Product Certifications | KERI || LROS (Lloyds register of shipping) || CSA || ATEX || UL || DNV || C-tick || RMRoS || CCC || RINA || ABS || EAC || GL || NOM || BV |
| Network And Machine Diagnosis Type | running hours counter/operating time || starting current and time || fault recording || trip history information || trip context information || phase fault and earth fault trip counters || motor control command recording || event recording || waiting time after overload tripping || remaining operating time before overload tripping |
| Contacts Type And Composition | 1 NO + 1 NC fault signal || 3 NO |
| Operating Altitude | u003c= 6561.68 ft (2000 m) without derating |
| Bus Type | DeviceNet ISO 1198 1 to 64 125 to 500 kbit/s, terminal block 4 twisted shielded pairs cable |
| Current State 1 Guaranteed | logic input 79 to 264 V u003e= 2 mA 25 ms |
| Load Current | 5 A 250 V AC logic output || 5 A 30 V DC logic output |
| Ip Degree Of Protection | IP20 |
| Web Services | web server |
| Protection Type | thermal overload protection || phase failure || overload || load fluctuation || power factor variation || overload (long time) || earth-leakage protection || reverse polarity protection || thermal protection || phase unbalance || locked rotor |
| Maximum Operating Rate | 1800 cyc/h |
| Product Name | TeSys T |
| Associated Fuse Rating | 4 A gG output || 0.5 A gG control circuit |
| Measurement Accuracy | 5 to 15 % earth fault current internal measurement || 1 % voltage 100 to 830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 1 % current || 5 % active and reactive power |
| Current State 0 Guaranteed | logic input 0 to 40 V u003c= 15 mA 25 ms |
| Range | TeSys |
| Short-Circuit Withstand | 100 kA conforming to EN/IEC 60947-4-1 |
| Connection Pitch | 5.08 mm |
| [Uimp] Rated Impulse Withstand Voltage | 4 kV supply, inputs and outputs EN/IEC 60947-4-1 || 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1 |
| Fire Resistance | 650ΓΒ°C EN/IEC 60695-2-12 || 960ΓΒ°C UL 94 |
| Current Consumption | 8 to 62.8 mA |
| Product Or Component Type | motor controller |
| Logic Input Number | 6 |
| Overall Depth | 4.82 in |
| Number of Normally Open Contacts | 4 |
| Overall Width | 3.58 in |
| Maximum Current Rating | 8 A |
| Overall Height | 2.4 in |
| Number of Normally Closed Contacts | 1 |
| Compatible with Series | TeSys T |
| Minimum Current Rating | 0.4 A |
| Number of Contacts Included | 5 |
| Country of Origin (subject to change) | China |
| Package Quantity | 1 |
Motor Manager, DeviceNet, 240VAC, 0.40-8A, Schneider Electric, Mfr#: LTMR08DFM
$725.99
Free shipping will be applied on orders over $50
Motor Management System, Number of Normally Open Contacts 4, Number of Normally Closed Contacts 1, Number of Contacts Included 5, Operating Voltage 690V AC, Control Voltage 100-240V AC, Interface DeviceNet, Compatible with Series TeSys T, Overall Width 3.58 in, Standards CSA C22.2 No 14, EN 60947-4-1, IACSE10, IEC 60947-4-1, KERI, nABS, nATEX, nBV, nC-tick, nCCC, nCSA, nDNV, nEAC, nGL, nLROS, nNOM, nRINA, nRMRoS, nUL, UL 508, Overall Height 2.4 in, Overall Depth 4.82 in
9999 in stock
Subtotal:
$725.99
You must be logged in to post a review.
Reviews
There are no reviews yet.