Motor Management System, Number of Normally Open Contacts 4, Number of Normally Closed Contacts 1, Number of Contacts Included 5, Operating Voltage 690V AC, Control Voltage 100-240V AC, Interface DeviceNet, Compatible with Series TeSys T, Overall Width 3.58 in, Standards CSA C22.2 No 14, EN 60947-4-1, IACSE10, IEC 60947-4-1, KERI, nABS, nATEX, nBV, nC-tick, nCCC, nCSA, nDNV, nEAC, nGL, nLROS, nNOM, nRINA, nRMRoS, nUL, UL 508, Overall Height 2.4 in, Overall Depth 4.82 in

9999 in stock

Must order in multiples of 1
Subtotal:
$732.99
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LTMR08DFM
Availability: Ships in 5 days
SKU: GRG2401822 Category:
ItemMotor Management System
Current Range0.40 to 8A
Control Voltage100-240V AC
Width3.58 in
InterfaceDeviceNet
Operating Voltage690V AC
Height2.4 in
Depth4.82 in
StandardsCSA C22.2 No 14, EN 60947-4-1, IACSE10, IEC 60947-4-1, KERI, nABS, nATEX, nBV, nC-tick, nCCC, nCSA, nDNV, nEAC, nGL, nLROS, nNOM, nRINA, nRMRoS, nUL, UL 508
For Use WithShort Circuit Protection And A Contactor
[Ui] Rated Insulation Voltage690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508
Pollution Degree3
Permissible Power480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
Ambient Air Temperature For Storage-40-80°C
Device Short NameLTMR
Device Applicationequipment monitoring and control
Ambient Air Temperature For Operation-20-60°C
[Us] Rated Supply Voltage100 to 240 V AC 50/60 Hz
Input Current3.1 mA 100 V || 7.5 mA 240 V
Connections - Terminalscontrol circuit connector 1 0.25-2.5 mm? AWG 24 to AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mm? AWG 24 to AWG 14)solid without cable end || control circuit connector 2 0.2-1 mm? AWG 24 to AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mm? AWG 24 to AWG 14)solid without cable end
Electromagnetic Compatibilityelectrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 || fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 || voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 || conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 || temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 || temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Communication Port ProtocolDeviceNet
Measurement Current0.4-8 A
Tightening Torquecontrol circuit 0.5-0.6 N.m flat 3 mm
Overvoltage CategoryIII
Protective Treatment12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068
Mechanical Robustnessvibrations mounted on symmetrical rail1 Gn, 5 to 300 Hz EN/IEC 60068-2-6 || vibrations plate mounted4 Gn, 5 to 300 Hz EN/IEC 60068-2-6 || shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27
Supply Voltage Limits93.5-264 V AC
Metering Typeimbalance current || earth-fault current || average current Iavg || temperature || phase current I1, I2, I3 RMS
Maximum Operating Frequency2 Hz
Compatibility CodeLTMR
Product CertificationsKERI || LROS (Lloyds register of shipping) || CSA || ATEX || UL || DNV || C-tick || RMRoS || CCC || RINA || ABS || EAC || GL || NOM || BV
Network And Machine Diagnosis Typerunning hours counter/operating time || starting current and time || fault recording || trip history information || trip context information || phase fault and earth fault trip counters || motor control command recording || event recording || waiting time after overload tripping || remaining operating time before overload tripping
Contacts Type And Composition1 NO + 1 NC fault signal || 3 NO
Operating Altitude<= 6561.68 ft (2000 m) without derating
Bus TypeDeviceNet ISO 1198 1 to 64 125 to 500 kbit/s, terminal block 4 twisted shielded pairs cable
Current State 1 Guaranteedlogic input 79 to 264 V >= 2 mA 25 ms
Load Current5 A 250 V AC logic output || 5 A 30 V DC logic output
Ip Degree Of ProtectionIP20
Web Servicesweb server
Protection Typethermal overload protection || phase failure || overload || load fluctuation || power factor variation || overload (long time) || earth-leakage protection || reverse polarity protection || thermal protection || phase unbalance || locked rotor
Maximum Operating Rate1800 cyc/h
Product NameTeSys T
Associated Fuse Rating4 A gG output || 0.5 A gG control circuit
Measurement Accuracy5 to 15 % earth fault current internal measurement || 1 % voltage 100 to 830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 1 % current || 5 % active and reactive power
Current State 0 Guaranteedlogic input 0 to 40 V <= 15 mA 25 ms
RangeTeSys
Short-Circuit Withstand100 kA conforming to EN/IEC 60947-4-1
Connection Pitch5.08 mm
[Uimp] Rated Impulse Withstand Voltage4 kV supply, inputs and outputs EN/IEC 60947-4-1 || 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1
Fire Resistance650°C EN/IEC 60695-2-12 || 960°C UL 94
Current Consumption8 to 62.8 mA
Product Or Component Typemotor controller
Logic Input Number6
Overall Depth4.82 in
Number of Normally Open Contacts4
Overall Width3.58 in
Maximum Current Rating8 A
Overall Height2.4 in
Number of Normally Closed Contacts1
Compatible with SeriesTeSys T
Minimum Current Rating0.4 A
Number of Contacts Included5
Country of Origin (subject to change)China
Package Quantity1
TAGS:
#Motor Manager
#DeviceNet
#240VAC
#0.40-8A
#SCHNEIDER ELECTRIC
#Mfr LTMR08DFM
#SCHNEIDER ELECTRIC
#GRG2401822
#mfr:LTMR08DFM
#part number:LTMR08DFM
#pn:LTMR08DFM
#part code:LTMR08DFM
#item number:LTMR08DFM
#product code:LTMR08DFM
#manufacturer number:LTMR08DFM
#manufacturers part number:LTMR08DFM
#mfn:LTMR08DFM

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!