Motor Management System, Number of Normally Open Contacts 4, Number of Normally Closed Contacts 1, Number of Contacts Included 5, Operating Voltage 690V AC, Control Voltage 100-240V AC, Interface Modbus, Compatible with Series TeSys T, Overall Width 3.58 in, Standards ABS, CSA C22.2 No 14, EN 60947-4-1, IACSE10, IEC 60947-4-1, nATEX, nBV, nC-tick, nCCC, nCSA, nDNV, nEAC, nGL, nKERI, nLROS, nNOM, nRINA, nRMRoS, nUL, UL 508, Overall Height 2.4 in, Overall Depth 4.82 in, Maximum Current Rating 8 A

9999 in stock

Must order in multiples of 1
Subtotal:
$729.99
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LTMR08MFM
Availability: Ships in 5 days
SKU: GRG0736531 Category:
ItemMotor Management System
Current Range0.40 to 8A
Control Voltage100-240V AC
Width3.58 in
InterfaceModbus
Operating Voltage690V AC
Height2.4 in
Depth4.82 in
For Use WithShort Circuit Protection And A Contactor
StandardsABS, CSA C22.2 No 14, EN 60947-4-1, IACSE10, IEC 60947-4-1, nATEX, nBV, nC-tick, nCCC, nCSA, nDNV, nEAC, nGL, nKERI, nLROS, nNOM, nRINA, nRMRoS, nUL, UL 508
Overvoltage CategoryIII
Metering Typeaverage current Iavg || temperature || earth-fault current || imbalance current || phase current I1, I2, I3 RMS
[Us] Rated Supply Voltage100 to 240 V AC 50/60 Hz
Current State 0 Guaranteedlogic input 0 to 40 V <= 15 mA 25 ms
Product NameTeSys T
Maximum Operating Rate1800 cyc/h
Pollution Degree3
Maximum Operating Frequency2 Hz
Connection Pitch5.08 mm
Bus TypeModbus 2-wire RS 485 1 to 247 1.2 to 19.2 kbit/s, RJ45 2 shielded twisted pairs || Modbus 2-wire RS 485 1 to 247 1.2 to 19.2 kbit/s, terminal block 2 shielded twisted pairs
Permissible Power480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
Current Consumption8 to 62.8 mA
Protective Treatment12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068
Input Current3.1 mA 100 V || 7.5 mA 240 V
[Uimp] Rated Impulse Withstand Voltage4 kV supply, inputs and outputs EN/IEC 60947-4-1 || 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1
Short-Circuit Withstand100 kA conforming to EN/IEC 60947-4-1
Current State 1 Guaranteedlogic input 79 to 264 V >= 2 mA 25 ms
Associated Fuse Rating4 A gG output || 0.5 A gG control circuit
Fire Resistance650°C EN/IEC 60695-2-12 || 960°C UL 94
Connections - Terminalscontrol circuit connector 1 0.25-2.5 mm? AWG 24 to AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mm? AWG 24 to AWG 14)solid without cable end || control circuit connector 2 0.2-1 mm? AWG 24 to AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mm? AWG 24 to AWG 14)solid without cable end
Tightening Torquecontrol circuit 0.5-0.6 N.m flat 3 mm
Logic Input Number6
Supply Voltage Limits93.5-264 V AC
Electromagnetic Compatibilityelectrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 || fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 || voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 || conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 || temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 || temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Network And Machine Diagnosis Typeevent recording || fault recording || waiting time after overload tripping || running hours counter/operating time || phase fault and earth fault trip counters || trip context information || starting current and time || motor control command recording || remaining operating time before overload tripping || trip history information
Protection Typereverse polarity protection || locked rotor || earth-leakage protection || thermal overload protection || phase failure || overload || thermal protection || power factor variation || load fluctuation || phase unbalance || overload (long time)
Ip Degree Of ProtectionIP20
Ambient Air Temperature For Storage-40-80°C
Web Servicesweb server
Product Or Component Typemotor controller
Mechanical Robustnessvibrations mounted on symmetrical rail1 Gn, 5 to 300 Hz EN/IEC 60068-2-6 || vibrations plate mounted4 Gn, 5 to 300 Hz EN/IEC 60068-2-6 || shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27
Contacts Type And Composition1 NO + 1 NC fault signal || 3 NO
Compatibility CodeLTMR
Device Applicationequipment monitoring and control
Measurement Current0.4-8 A
Ambient Air Temperature For Operation-20-60°C
[Ui] Rated Insulation Voltage690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508
Device Short NameLTMR
Load Current5 A 250 V AC logic output || 5 A 30 V DC logic output
Operating Altitude<= 6561.68 ft (2000 m) without derating
Product CertificationsABS || KERI || BV || EAC || CSA || GL || C-tick || ATEX || UL || RMRoS || NOM || CCC || DNV || RINA || LROS (Lloyds register of shipping)
Communication Port ProtocolModbus
RangeTeSys
Measurement Accuracy5 to 15 % earth fault current internal measurement || 1 % voltage 100 to 830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 1 % current || 5 % active and reactive power
Overall Width3.58 in
Overall Height2.4 in
Maximum Current Rating8 A
Number of Normally Closed Contacts1
Overall Depth4.82 in
Number of Normally Open Contacts4
Minimum Current Rating0.4 A
Number of Contacts Included5
Compatible with SeriesTeSys T
Country of Origin (subject to change)China
Package Quantity1
TAGS:
#Motor Manager
#Modbus
#100-240VAC
#0.40-8A
#SCHNEIDER ELECTRIC
#Mfr LTMR08MFM
#SCHNEIDER ELECTRIC
#GRG0736531
#mfr:LTMR08MFM
#part number:LTMR08MFM
#pn:LTMR08MFM
#part code:LTMR08MFM
#item number:LTMR08MFM
#product code:LTMR08MFM
#manufacturer number:LTMR08MFM
#manufacturers part number:LTMR08MFM
#mfn:LTMR08MFM

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!