Motor Manager, Modbus, 24VDC, 0.40-8A, SCHNEIDER ELECTRIC, Mfr# LTMR08MBD

$1044,99

Free shipping will be applied on orders over $50

Motor Management System, Number of Normally Open Contacts 4, Number of Normally Closed Contacts 1, Number of Contacts Included 5, Operating Voltage 690V AC, Control Voltage 24V DC, Interface Modbus, Compatible with Series TeSys T, Overall Width 3.58 in, Standards CSA C22.2 No 14, DNV, EN 60947-4-1, IACSE10, IEC 60947-4-1, nABS, nATEX, nBV, nC-tick, nCCC, nCSA, nEAC, nGL, nKERI, nLROS, nNOM, nRINA, nRMRoS, nUL, UL 508, Overall Height 2.4 in, Overall Depth 4.82 in, Maximum Current Rating 8 A

9999 in stock

Must order in multiples of 1
Subtotal:
$1044.99
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LTMR08MBD
Availability: Ships in 65 days
SKU: GRG1414445 Category:
ItemMotor Management System
Current Range0.40 to 8A
Control Voltage24V DC
Width3.58 in
InterfaceModbus
Operating Voltage690V AC
Height2.4 in
Depth4.82 in
StandardsCSA C22.2 No 14, DNV, EN 60947-4-1, IACSE10, IEC 60947-4-1, nABS, nATEX, nBV, nC-tick, nCCC, nCSA, nEAC, nGL, nKERI, nLROS, nNOM, nRINA, nRMRoS, nUL, UL 508
For Use WithShort Circuit Protection And A Contactor
Network And Machine Diagnosis Typerunning hours counter/operating time || trip history information || phase fault and earth fault trip counters || fault recording || waiting time after overload tripping || remaining operating time before overload tripping || trip context information || starting current and time || event recording || motor control command recording
Permissible Power480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
Maximum Operating Rate1800 cyc/h
Compatibility CodeLTMR
Ambient Air Temperature For Operation-20-60°C
Connection Pitch5.08 mm
Communication Port ProtocolModbus
[Us] Rated Supply Voltage24 V DC
Product NameTeSys T
Bus TypeModbus 2-wire RS 485 1 to 247 1.2 to 19.2 kbit/s, RJ45 2 shielded twisted pairs || Modbus 2-wire RS 485 1 to 247 1.2 to 19.2 kbit/s, terminal block 2 shielded twisted pairs
Electromagnetic Compatibilityelectrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 || radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 || fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 || voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 || conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 || temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 || temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Associated Fuse Rating4 A gG output || 0.5 A gG control circuit
Ambient Air Temperature For Storage-40-80°C
Supply Voltage Limits20.4-26.24 V DC
Measurement Accuracy5 to 15 % earth fault current internal measurement || 1 % voltage 100 to 830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 1 % current || 5 % active and reactive power
[Uimp] Rated Impulse Withstand Voltage6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1 || 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1
Input Current7 mA
Ip Degree Of ProtectionIP20
Short-Circuit Withstand100 kA conforming to EN/IEC 60947-4-1
Product Or Component Typemotor controller
Protection Typephase unbalance || locked rotor || power factor variation || load fluctuation || overload || overload (long time) || phase failure || thermal protection || thermal overload protection || earth-leakage protection || reverse polarity protection
Overvoltage CategoryIII
Load Current5 A 250 V AC logic output || 5 A 30 V DC logic output
Operating Altitude<= 6561.68 ft (2000 m) without derating
Contacts Type And Composition1 NO + 1 NC fault signal || 3 NO
Maximum Operating Frequency2 Hz
Measurement Current0.4-8 A
RangeTeSys
Web Servicesweb server
Tightening Torquecontrol circuit 0.5-0.6 N.m flat 3 mm
Current Consumption56 to 127 mA
Current State 1 Guaranteedlogic input < 15 V 2 to 15 mA 15 ms
Connections - Terminalscontrol circuit connector 1 0.25-2.5 mm? AWG 24 to AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mm? AWG 24 to AWG 14)solid without cable end || control circuit connector 2 0.2-1 mm? AWG 24 to AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mm? AWG 24 to AWG 14)solid without cable end
Device Applicationequipment monitoring and control
[Ui] Rated Insulation Voltage690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508
Product CertificationsDNV || EAC || ABS || BV || CSA || UL || RINA || RMRoS || CCC || GL || KERI || LROS (Lloyds register of shipping) || NOM || ATEX || C-tick
Device Short NameLTMR
Mechanical Robustnessvibrations mounted on symmetrical rail1 Gn, 5 to 300 Hz EN/IEC 60068-2-6 || vibrations plate mounted4 Gn, 5 to 300 Hz EN/IEC 60068-2-6 || shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27
Logic Input Number6
Current State 0 Guaranteedlogic input < 5 V <= 15 mA 5 ms
Protective Treatment12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068
Metering Typeaverage current Iavg || earth-fault current || phase current I1, I2, I3 RMS || imbalance current || temperature
Pollution Degree3
Fire Resistance650°C EN/IEC 60695-2-12 || 960°C UL 94
Overall Height2.4 in
Overall Depth4.82 in
Maximum Current Rating8 A
Number of Contacts Included5
Number of Normally Open Contacts4
Compatible with SeriesTeSys T
Minimum Current Rating0.4 A
Number of Normally Closed Contacts1
Overall Width3.58 in
Country of Origin (subject to change)China
Package Quantity1
TAGS:
#Motor Manager
#Modbus
#24VDC
#0.40-8A
#SCHNEIDER ELECTRIC
#Mfr LTMR08MBD
#SCHNEIDER ELECTRIC
#GRG1414445
#mfr:LTMR08MBD
#part number:LTMR08MBD
#pn:LTMR08MBD
#part code:LTMR08MBD
#item number:LTMR08MBD
#product code:LTMR08MBD
#manufacturer number:LTMR08MBD
#manufacturers part number:LTMR08MBD
#mfn:LTMR08MBD

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!