Motor Manager, Modbus, 24VDC, 1.35-27A, SCHNEIDER ELECTRIC, Mfr# LTMR27MBD

$1044,99

Free shipping will be applied on orders over $50

Motor Management System, Number of Normally Open Contacts 4, Number of Normally Closed Contacts 1, Number of Contacts Included 5, Operating Voltage 690V AC, Control Voltage 24V DC, Interface Modbus, Compatible with Series TeSys T, Overall Width 3.58 in, Standards CSA C22.2 No 14, EN 60947-4-1, IACSE10, IEC 60947-4-1, nABS, nATEX, nBV, nC-tick, nCCC, nCSA, nDNV, nEAC, nGL, nKERI, nLROS, nNOM, nRINA, nUL, RMRoS, UL 508, Overall Height 2.4 in, Overall Depth 4.82 in, Maximum Current Rating 27 A

Out of stock

Brand Name: SCHNEIDER ELECTRIC
Mfr #: LTMR27MBD
Availability: Ships in 5 days
SKU: GRG1759055 Category:
ItemMotor Management System
Current Range1.35 to 27A
Control Voltage24V DC
Width3.58 in
InterfaceModbus
Operating Voltage690V AC
Height2.4 in
Depth4.82 in
StandardsCSA C22.2 No 14, EN 60947-4-1, IACSE10, IEC 60947-4-1, nABS, nATEX, nBV, nC-tick, nCCC, nCSA, nDNV, nEAC, nGL, nKERI, nLROS, nNOM, nRINA, nUL, RMRoS, UL 508
For Use WithShort Circuit Protection And A Contactor
Associated Fuse Rating4 A gG output || 0.5 A gG control circuit
Electromagnetic Compatibilityelectrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 || radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 || fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 || voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 || conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 || temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 || temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Measurement Accuracy5 to 15 % earth fault current internal measurement || 1 % voltage 100 to 830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 1 % current || 5 % active and reactive power
Bus TypeModbus 2-wire RS 485 1 to 247 1.2 to 19.2 kbit/s, RJ45 2 shielded twisted pairs || Modbus 2-wire RS 485 1 to 247 1.2 to 19.2 kbit/s, terminal block 2 shielded twisted pairs
Web Servicesweb server
Maximum Operating Rate1800 cyc/h
Mechanical Robustnessvibrations mounted on symmetrical rail1 Gn, 5 to 300 Hz EN/IEC 60068-2-6 || vibrations plate mounted4 Gn, 5 to 300 Hz EN/IEC 60068-2-6 || shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27
[Us] Rated Supply Voltage24 V DC
Protection Typethermal overload protection || locked rotor || earth-leakage protection || thermal protection || phase failure || phase unbalance || reverse polarity protection || overload (long time) || overload || power factor variation || load fluctuation
Short-Circuit Withstand100 kA conforming to EN/IEC 60947-4-1
Ambient Air Temperature For Operation-20-60°C
Product CertificationsRMRoS || CSA || NOM || BV || KERI || EAC || LROS (Lloyds register of shipping) || ATEX || ABS || C-tick || RINA || CCC || UL || GL || DNV
Current State 0 Guaranteedlogic input < 5 V <= 15 mA 5 ms
Connections - Terminalscontrol circuit connector 1 0.25-2.5 mm? AWG 24 to AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mm? AWG 24 to AWG 14)solid without cable end || control circuit connector 2 0.2-1 mm? AWG 24 to AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mm? AWG 24 to AWG 14)solid without cable end
Permissible Power480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
Input Current7 mA
Compatibility CodeLTMR
Load Current5 A 250 V AC logic output || 5 A 30 V DC logic output
Device Applicationequipment monitoring and control
Metering Typetemperature || average current Iavg || earth-fault current || imbalance current || phase current I1, I2, I3 RMS
Contacts Type And Composition1 NO + 1 NC fault signal || 3 NO
Ambient Air Temperature For Storage-40-80°C
Device Short NameLTMR
Communication Port ProtocolModbus
RangeTeSys
[Uimp] Rated Impulse Withstand Voltage6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1 || 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1
Supply Voltage Limits20.4-26.24 V DC
[Ui] Rated Insulation Voltage690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508
Overvoltage CategoryIII
Protective Treatment12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068
Connection Pitch5.08 mm
Fire Resistance650°C EN/IEC 60695-2-12 || 960°C UL 94
Pollution Degree3
Product NameTeSys T
Operating Altitude<= 6561.68 ft (2000 m) without derating
Network And Machine Diagnosis Typestarting current and time || running hours counter/operating time || remaining operating time before overload tripping || trip history information || trip context information || event recording || waiting time after overload tripping || phase fault and earth fault trip counters || fault recording || motor control command recording
Current Consumption56 to 127 mA
Product Or Component Typemotor controller
Maximum Operating Frequency2 Hz
Current State 1 Guaranteedlogic input < 15 V 2 to 15 mA 15 ms
Logic Input Number6
Ip Degree Of ProtectionIP20
Tightening Torquecontrol circuit 0.5-0.6 N.m flat 3 mm
Measurement Current1.35-27 A
Number of Normally Open Contacts4
Overall Width3.58 in
Compatible with SeriesTeSys T
Minimum Current Rating1.35 A
Maximum Current Rating27 A
Overall Depth4.82 in
Number of Contacts Included5
Overall Height2.4 in
Number of Normally Closed Contacts1
Country of Origin (subject to change)China
Package Quantity1
TAGS:
#Motor Manager
#Modbus
#24VDC
#1.35-27A
#SCHNEIDER ELECTRIC
#Mfr LTMR27MBD
#SCHNEIDER ELECTRIC
#GRG1759055
#mfr:LTMR27MBD
#part number:LTMR27MBD
#pn:LTMR27MBD
#part code:LTMR27MBD
#item number:LTMR27MBD
#product code:LTMR27MBD
#manufacturer number:LTMR27MBD
#manufacturers part number:LTMR27MBD
#mfn:LTMR27MBD

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!