Motor Management System, Number of Normally Open Contacts 4, Number of Normally Closed Contacts 1, Number of Contacts Included 5, Operating Voltage 690V AC, Control Voltage 24V DC, Interface Modbus, Compatible with Series TeSys T, Overall Width 3.58 in, Standards CSA C22.2 No 14, EN 60947-4-1, IACSE10, IEC 60947-4-1, nABS, nATEX, nBV, nC-tick, nCCC, nCSA, nDNV, nEAC, nGL, nKERI, nLROS, NOM, nRINA, nRMRoS, nUL, UL 508, Overall Height 2.4 in, Overall Depth 4.82 in, Maximum Current Rating 100 A

Out of stock

Brand Name: SCHNEIDER ELECTRIC
Mfr #: LTMR100MBD
Availability: Ships in 65 days
SKU: GRG0907322 Category:
ItemMotor Management System
Current Range5 to 100A
Control Voltage24V DC
Width3.58 in
InterfaceModbus
Operating Voltage690V AC
Height2.4 in
Depth4.82 in
StandardsCSA C22.2 No 14, EN 60947-4-1, IACSE10, IEC 60947-4-1, nABS, nATEX, nBV, nC-tick, nCCC, nCSA, nDNV, nEAC, nGL, nKERI, nLROS, NOM, nRINA, nRMRoS, nUL, UL 508
For Use WithShort Circuit Protection And A Contactor
Maximum Operating Frequency2 Hz
Network And Machine Diagnosis Typeremaining operating time before overload tripping || phase fault and earth fault trip counters || fault recording || waiting time after overload tripping || motor control command recording || event recording || starting current and time || trip history information || running hours counter/operating time || trip context information
Product NameTeSys T
Contacts Type And Composition1 NO + 1 NC fault signal || 3 NO
Fire Resistance650°C EN/IEC 60695-2-12 || 960°C UL 94
[Ui] Rated Insulation Voltage690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508
Product CertificationsNOM || RMRoS || DNV || C-tick || RINA || CSA || BV || GL || KERI || EAC || LROS (Lloyds register of shipping) || ABS || UL || CCC || ATEX
Operating Altitude<= 6561.68 ft (2000 m) without derating
Protection Typethermal overload protection || phase unbalance || overload (long time) || phase failure || thermal protection || power factor variation || reverse polarity protection || overload || locked rotor || load fluctuation || earth-leakage protection
Connections - Terminalscontrol circuit connector 1 0.25-2.5 mm? AWG 24 to AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mm? AWG 24 to AWG 14)solid without cable end || control circuit connector 2 0.2-1 mm? AWG 24 to AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mm? AWG 24 to AWG 14)solid without cable end
Supply Voltage Limits20.4-26.24 V DC
Measurement Current5-100 A
Tightening Torquecontrol circuit 0.5-0.6 N.m flat 3 mm
Protective Treatment12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068
Device Applicationequipment monitoring and control
Electromagnetic Compatibilityelectrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 || radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 || fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 || voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 || conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 || temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 || temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Connection Pitch5.08 mm
Current Consumption56 to 127 mA
Current State 0 Guaranteedlogic input < 5 V <= 15 mA 5 ms
RangeTeSys
Mechanical Robustnessvibrations mounted on symmetrical rail1 Gn, 5 to 300 Hz EN/IEC 60068-2-6 || vibrations plate mounted4 Gn, 5 to 300 Hz EN/IEC 60068-2-6 || shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27
Communication Port ProtocolModbus
Device Short NameLTMR
[Uimp] Rated Impulse Withstand Voltage6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1 || 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1
Load Current5 A 250 V AC logic output || 5 A 30 V DC logic output
Ambient Air Temperature For Operation-20-60°C
Short-Circuit Withstand100 kA conforming to EN/IEC 60947-4-1
Permissible Power480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
Logic Input Number6
Ip Degree Of ProtectionIP20
Associated Fuse Rating4 A gG output || 0.5 A gG control circuit
Compatibility CodeLTMR
Overvoltage CategoryIII
Input Current7 mA
Maximum Operating Rate1800 cyc/h
Metering Typephase current I1, I2, I3 RMS || temperature || average current Iavg || earth-fault current || imbalance current
[Us] Rated Supply Voltage24 V DC
Measurement Accuracy5 to 15 % earth fault current internal measurement || 1 % voltage 100 to 830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 5 % active and reactive power || 0,02 current
Current State 1 Guaranteedlogic input < 15 V 2 to 15 mA 15 ms
Pollution Degree3
Bus TypeModbus 2-wire RS 485 1 to 247 1.2 to 19.2 kbit/s, RJ45 2 shielded twisted pairs || Modbus 2-wire RS 485 1 to 247 1.2 to 19.2 kbit/s, terminal block 2 shielded twisted pairs
Web Servicesweb server
Product Or Component Typemotor controller
Ambient Air Temperature For Storage-40-80°C
Overall Height2.4 in
Maximum Current Rating100 A
Compatible with SeriesTeSys T
Overall Width3.58 in
Number of Normally Closed Contacts1
Overall Depth4.82 in
Number of Contacts Included5
Minimum Current Rating5 A
Number of Normally Open Contacts4
Country of Origin (subject to change)China
Package Quantity1
TAGS:
#Motor Manager
#Modbus
#24VDC
#5-100A
#SCHNEIDER ELECTRIC
#Mfr LTMR100MBD
#SCHNEIDER ELECTRIC
#GRG0907322
#mfr:LTMR100MBD
#part number:LTMR100MBD
#pn:LTMR100MBD
#part code:LTMR100MBD
#item number:LTMR100MBD
#product code:LTMR100MBD
#manufacturer number:LTMR100MBD
#manufacturers part number:LTMR100MBD
#mfn:LTMR100MBD

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!