Item | Motor Management System |
Current Range | 5 to 100A |
Control Voltage | 100-240V AC |
Width | 3.58 in |
Interface | Profibus DP |
Operating Voltage | 690V AC |
Height | 2.4 in |
Depth | 4.82 in |
For Use With | Short Circuit Protection And A Contactor |
Standards | CSA C22.2 No 14, EN 60947-4-1, IACSE10, IEC 60947-4-1, KERI, nABS, nATEX, nBV, nC-tick, nCCC, nCSA, nDNV, nEAC, nGL, nLROS, nNOM, nRINA, nRMRoS, nUL, UL 508 |
Protective Treatment | 12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068 |
Bus Type | Profibus DP polarised 2-wire RS485 1 to 125 9.6 kbit/s to 12 Mbit/s, SUB-D 9 2 shielded twisted pairs, type A || Profibus DP polarised 2-wire RS485 1 to 125 9.6 kbit/s to 12 Mbit/s, terminal block 2 shielded twisted pairs, type A |
Input Current | 3.1 mA 100 V || 7.5 mA 240 V |
Overvoltage Category | III |
Compatibility Code | LTMR |
Current State 0 Guaranteed | logic input 0 to 40 V <= 15 mA 25 ms |
Ip Degree Of Protection | IP20 |
Supply Voltage Limits | 93.5-264 V AC |
Product Or Component Type | motor controller |
Ambient Air Temperature For Storage | -40-80°C |
Range | TeSys |
Network And Machine Diagnosis Type | starting current and time || trip history information || running hours counter/operating time || phase fault and earth fault trip counters || trip context information || event recording || remaining operating time before overload tripping || motor control command recording || waiting time after overload tripping || fault recording |
Ambient Air Temperature For Operation | -20-60°C |
Web Services | web server |
Connection Pitch | 5.08 mm |
Operating Altitude | <= 6561.68 ft (2000 m) without derating |
Tightening Torque | control circuit 0.5-0.6 N.m flat 3 mm |
Load Current | 5 A 250 V AC logic output || 5 A 30 V DC logic output |
Contacts Type And Composition | 1 NO + 1 NC fault signal || 3 NO |
Product Name | TeSys T |
Device Application | equipment monitoring and control |
Maximum Operating Rate | 1800 cyc/h |
Protection Type | thermal overload protection || power factor variation || overload || locked rotor || thermal protection || reverse polarity protection || phase unbalance || earth-leakage protection || phase failure || load fluctuation || overload (long time) |
Pollution Degree | 3 |
Measurement Current | 5-100 A |
Permissible Power | 480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output) |
Maximum Operating Frequency | 2 Hz |
Measurement Accuracy | 5 to 15 % earth fault current internal measurement || 1 % voltage 100 to 830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 5 % active and reactive power || 0,02 current |
[Us] Rated Supply Voltage | 100 to 240 V AC 50/60 Hz |
[Ui] Rated Insulation Voltage | 690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508 |
Communication Port Protocol | Profibus DP |
Metering Type | earth-fault current || phase current I1, I2, I3 RMS || temperature || imbalance current || average current Iavg |
Product Certifications | KERI || RMRoS || ABS || UL || ATEX || NOM || RINA || BV || CCC || GL || DNV || CSA || LROS (Lloyds register of shipping) || EAC || C-tick |
Connections - Terminals | control circuit connector 1 0.25-2.5 mm? AWG 24 to AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mm? AWG 24 to AWG 14)solid without cable end || control circuit connector 2 0.2-1 mm? AWG 24 to AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mm? AWG 24 to AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mm? AWG 24 to AWG 14)solid without cable end |
[Uimp] Rated Impulse Withstand Voltage | 4 kV supply, inputs and outputs EN/IEC 60947-4-1 || 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1 |
Current State 1 Guaranteed | logic input 79 to 264 V >= 2 mA 25 ms |
Fire Resistance | 650°C EN/IEC 60695-2-12 || 960°C UL 94 |
Short-Circuit Withstand | 100 kA conforming to EN/IEC 60947-4-1 |
Device Short Name | LTMR |
Logic Input Number | 6 |
Current Consumption | 8 to 62.8 mA |
Mechanical Robustness | vibrations mounted on symmetrical rail1 Gn, 5 to 300 Hz EN/IEC 60068-2-6 || vibrations plate mounted4 Gn, 5 to 300 Hz EN/IEC 60068-2-6 || shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27 |
Associated Fuse Rating | 4 A gG output || 0.5 A gG control circuit |
Electromagnetic Compatibility | electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 || fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 || voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 || conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 || temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 || temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5 |
Overall Depth | 4.82 in |
Number of Contacts Included | 5 |
Overall Height | 2.4 in |
Compatible with Series | TeSys T |
Overall Width | 3.58 in |
Number of Normally Open Contacts | 4 |
Maximum Current Rating | 100 A |
Minimum Current Rating | 5 A |
Number of Normally Closed Contacts | 1 |
Country of Origin (subject to change) | China |
Package Quantity | 1 |
Motor Manager, Profibus DP, 240VAC, 5-100A, SCHNEIDER ELECTRIC, Mfr# LTMR100PFM
$830,99
Free shipping will be applied on orders over $50
Motor Management System, Number of Normally Open Contacts 4, Number of Normally Closed Contacts 1, Number of Contacts Included 5, Operating Voltage 690V AC, Control Voltage 100-240V AC, Interface Profibus DP, Compatible with Series TeSys T, Overall Width 3.58 in, Standards CSA C22.2 No 14, EN 60947-4-1, IACSE10, IEC 60947-4-1, KERI, nABS, nATEX, nBV, nC-tick, nCCC, nCSA, nDNV, nEAC, nGL, nLROS, nNOM, nRINA, nRMRoS, nUL, UL 508, Overall Height 2.4 in, Overall Depth 4.82 in