Gas Detected
Carbon Monoxide, Hydrogen Sulfide, LEL, Oxygen
Alarm Type
Audible, Vibrating, Visual
Alarm Setting
Carbon Monoxide (Alarm 1 - 35 ppm, Alarm 2 - 50 ppm), Hydrogen Sulfide (Alarm 1 - 10 ppm, Alarm 2 - 15 ppm), LEL (Alarm - 10%, Alarm 2 - 20%), Oxygen (Alarm 1 - 19.5%, Alarm 2 - 23.5%)
Operating Temp. Range
-40 Degrees to 140 Degrees F
Standards
CAN/CSA C22.2 No. 152 Combustible Gas Detection Instruments C22.2 No. 152, CE 0080 Directive 2014/30/EU (EMC): EN50270 Type 2, EN61000-6-3, Directive 2014/34/EU (ATEX): II 1G Ex ia da IIC T4 Ga, Ex ia da IIC T4 Ga, IECEX, ISO 9001
Sensor Range
CO 0 to 1999 ppm, H2S 0 to 200 ppm, LEL 0 to 100%, O2 0 to 30% Vol.
Includes
34 L Calibration Cylinder, Calibration Cap with Tubing, Case, Kit, Monitor, Pump Probe, Regulator
Features
Bluetooth Capability, Water Resistant, Integrated Sampling Pump, Standard Data Logging and Event Logging
Resolution
1% LEL, Carbon Monoxide 1 ppm, Hydrogen Sulfide 1 ppm, Oxygen 0.1% vol
Chemical Formula
CO, H2S, O2
Operating Temperature - Minimum
-40 Degrees F
Number of Gases Detected
4
Operating Humidity - Minimum
5 %
Measurement Range
Carbon Monoxide (0 to 1,999 ppm), Hydrogen Sulfide (0 to 200 ppm), LEL 0 to 100%, Oxygen (0 to 30% vol)
Communication Protocol
Bluetooth
Display Screen Type
Monochrome
Manufacturer Warranty Length
4 yr
Alert Type
Light, Sound, Vibration
Hazardous Location Specification
Class I Divisions 1 Groups A, B, C, D, Class II Divisions 1 Groups E, F, G, Class III Divisions 1
Battery Chemistry
Lithium Ion Polymer
Operating Humidity - Maximum
95 %
Operating Temperature - Maximum
140 Degrees F
Resistance Properties
Water Resistant
Country of Origin (subject to change)
United States