Gas Detected
Carbon Monoxide, Combustible Gas, Hydrogen Sulfide, Oxygen
Alarm Type
Audible, Vibrating, Visual
Alarm Setting
20 ppm Danger, 20% Danger, 70 ppm Danger, Carbon Monoxide 35 ppm Warning, Hydrogen Sulfide 10 ppm Warning, LEL 10%, Oxygen (High 23.5%, Low 19.5%)
Operating Temp. Range
-4 Degrees to 122 Degrees F (-20 Degrees to 50 Degrees C)
Standards
UL Class I, Groups A, B, C, D T4. Zone 0. Class II, Groups F,G. AEx ia d IIC T4. CSA: Class l Division l Groups A, B, C, D T4. Ex d ia IIC T4. MSHA: CFR30, Part 22, Permissible for Underground Mines Diffusion Versions Only. IECEX Ex ia IIC. IP66 IP67
Sensor Range
CO 0 to 1000 ppm, H2S 0 to 500 ppm, LEL 0 to 100%, O2 0 to 30.0%
Features
Detects 1 to 4 Gases, One Button Operation
Includes
Calibration Fitting, Calibration Gas (Appropriate Mix) with Regulator, Calibration Tubing, CO Monitor with Pump, Dust Filter/Water Stop, H2S, LEL, Rugged Hard Plastic Case, Sample Tubing, Service Tool, Soft Carrying Case, Ventis(TM) MX4 O2
Resolution
1% LEL, Carbon Monoxide 1 ppm, Hydrogen Sulfide 0.1 ppm, Oxygen 0.1% vol
Chemical Formula
CO, H2S, O2
Operating Temperature - Maximum
122 Degrees F
Number of Gases Detected
4
Communication Protocol
Wireless
Measurement Range
Oxygen (0 to 30% vol)
Operating Temperature - Minimum
-4 Degrees F
Alarm Setting Adjustment
Adjustable Alarm Setting
Alert Type
Light, Sound, Vibration
Battery Chemistry
Lithium Ion
Manufacturer Warranty Length
2 yr
Country of Origin (subject to change)
United States