AC Contact Rating - Relay
10A @ 120/240/480/600V
DC Contact Rating - Relay
5A @ 125/250V
Features
Contact Conversion without Removing Terminal Screws or Wires, Plug-in Contact Cartridges for Easy Contact Conversion and Replacement, Replaceable Coil, Self-Lifting Pressure Wire Connectors, Straight-Through Wiring
Contact Amp Rating (Resistive)
10A
Response Time
21 msec (Drop-Out Time), 37 msec (Pick-Up Time)
Overall Height - Relay
3.5 in
Contact Material
Silver Cadmium Oxide
Item - Relay
NEMA Style Control Relay
Standards
CSA Certified, RoHS Compliant, UL Listed
Body Width - Relay
2.23 in
Body Height - Relay
3.5 in
Contact Form - Relay
(2) SPST-NO
Body Depth - Relay
5.17 in
Power Consumption - Relay
18.0 W
Line Rated Current
10 A AC || 5 A DC
Control Circuit Voltage Limits
operational 0.8 to 1.1 Uc DC
Hold-In Power Consumption In W
18-18 W
Contacts Type And Composition
2 NO 2 standard contact cartridges
Ambient Air Temperature For Operation
-40-160 °F
Product Or Component Type
relay
Product Certifications
UL listed file E78403 CCN NKCR || CSA LR60905 class 3211 03
[Icm] Rated Short-Circuit Making Capacity
60 A 120 V AC inductive control circuit UL 508 || 0.8 A 250 V DC resistive control circuit UL 508 || 30 A 240 V AC inductive control circuit UL 508 || 15 A 480 V AC inductive control circuit UL 508 || 12 A 600 V AC inductive control circuit UL 508 || 10 A u003c= 600 V AC resistive control circuit UL 508 || 1.1 A 125 V DC inductive control circuit UL 508 || 0.55 A 250 V DC inductive control circuit UL 508 || 0.2 A 301 to 600 V DC inductive control circuit UL 508 || 4 A 125 V DC inductive control circuit UL 508
[Uc] Control Circuit Voltage
24 V DC
Operating Time
37 ms - pick-up || 21 ms - drop-out
Electrical Connection
Screw Clamp
Rated Breaking Capacity
6 A 120 V AC inductive control circuit UL 508 || 0.8 A 250 V DC resistive control circuit UL 508 || 3 A 240 V AC inductive control circuit UL 508 || 1.5 A 480 V AC inductive control circuit UL 508 || 1.2 A 600 V AC inductive control circuit UL 508 || 10 A u003c= 600 V AC resistive control circuit UL 508 || 1.1 A 125 V DC inductive control circuit UL 508 || 0.55 A 250 V DC inductive control circuit UL 508 || 0.2 A 301 to 600 V DC inductive control circuit UL 508 || 4 A 125 V DC resistive control circuit UL 508
Tightening Torque
control circuit 1.02-1.36 N.m screw terminals
Awg Gauge
AWG 18 to AWG 12 copper
Maximum Operating Temperature
160 Degrees F
Contact Rating (DC)
0.2 A @ 301-600V, 0.55 A @ 250V, 0.8 A @ 250V, 1.1 A @ 125V, 4 A @ 125V
Contact Rating (AC)
10 A @ 600V
Minimum Operating Temperature
-40 Degrees F
Compatible with Series
8501 Type X Latching Control Relays
Country of Origin (subject to change)
Mexico