Item | NEMA Magnetic Motor Starter |
Overload Relay Amp Setting | 10 to 40A |
Coil Volts | 480V AC |
Enclosure NEMA Rating | No Enclosure |
Auxiliary Contact Form | 1NO |
HP @ 3 Phase - 240V | 7 1/2 hp |
Starter Type | NEMA Style |
Action | Nonreversing |
Amps AC | 27 |
NEMA Size | 1 |
Number of Poles | 3 |
HP @ 3 Phase - 480V | 10 hp |
Width | 3.5 in |
Standards | CSA 22.2 No.14, NEMA ICS 2, UL 508 |
Depth | 3.75 in |
HP @ 3 Phase - 208V | 7 1/2 hp |
Hz | 50/60 |
Height | 7.44 in |
Thermal Unit Code | Not Applicable |
Maximum Voltage Rating | 600V AC |
Horsepower @ Three Phase - 480V AC | 0 hp |
NEMA Enclosure Rating | No Enclosure |
Includes Auxiliary Contacts | Yes |
Maximum Overload Relay Current Setting | 40 A |
Overload Protection Type | Electronic |
Mounting Style | Surface |
Minimum Operating Temperature | -4 Degrees F |
Overall Height | 7.44 in |
Overall Width | 5.75 in |
Terminal Connection Type | Screw Terminals |
Starter Style | NEMA |
Horsepower @ Three Phase - 600V AC | 0 hp |
Mounting Postion | Vertical |
Horsepower @ Three Phase - 208V AC | 7 1/2 hp |
Resistance Properties | Corrosion Resistant, Dust Resistant, Watertight |
Current AC | 27 A |
Series | FVNR |
Reversing Capability | Non-Reversing |
Number of Auxillary Contacts | 1 |
Response Time | 10 to 24 msec (OFF-Delay Time), 19 to 29 msec (ON-Delay Time) |
Phase | Three |
Mechanical Operating Durability | 10,000,000 |
Coil Voltage | 380-440/440-480V AC |
Maximum Operating Temperature | 104 Degrees F |
Auxiliary Contact Module Capacity | 8 |
Minimum Overload Relay Current Setting | 10 A |
Trip Class | 5/10/20/30 |
Frequency | 50/60 Hz |
Horsepower @ Three Phase - 240V AC | 7 1/2 hp |
Overall Depth | 3.75 in |
Country of Origin (subject to change) | Mexico |
Package Quantity | 1 |
Nonreversing NEMA Magnetic Motor Starter, No Enclosure NEMA Rating, 480V AC, 3 Poles, 1NO, SIEMENS, Mfr# 14DUE32AH
$420.00
Free shipping will be applied on orders over $50
NEMA Magnetic Motor Starter, Includes Auxiliary Contacts Yes, Maximum Overload Relay Current Setting 40 A, Overload Protection Type Electronic, Minimum Overload Relay Current Setting 10 A, Trip Class 5/10/20/30, Series FVNR, Number of Poles 3, Number of Auxillary Contacts 1, Phase Three, Mounting Style Surface, Auxiliary Contact Form 1NO, Starter Style NEMA, Reversing Capability Non-Reversing, Maximum Voltage Rating 600V AC, Coil Voltage 380-440/440-480V AC
9999 in stock
Must order in multiples of 1
Subtotal:
$420.00
You must be logged in to post a review.
WARNING: Reproductive Harm - www.P65Warnings.ca.gov