| Property | Value |
|---|---|
| Item | Overload Module |
| Voltage | 110-240V AC/110-220V DC |
| Phase | Single |
| Thermal Setting Range (A) | 3.00 to 12.00 |
| For Use With | LUxB32, LUxS12, LUxS32 Power Bases, Mfr. Series LUxB12 |
| Reset Type - Relay | Manual |
| Standards | ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed |
| Current Range | 3.00 to 12.0A |
| Trip Class | 10 |
| Features | Earth Fault Protection |
| Sensing Method | Electronic |
| Number of Poles | 3 |
| Trip Class - Overload | 10 |
| Minimum Operating Temperature | -13 Degrees F |
| Reset Type | Manual |
| Maximum Voltage Rating | 690V AC |
| Minumum Rated Motor Current Adjustment | 3 A |
| Terminal Connection Type | Wire Leads |
| Compatible with Manufacturer Model Number | LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380 |
| Coil Voltage | 110-240V AC/DC |
| Maximum Operating Temperature | 158 Degrees F |
| Compatible with Series | TeSys Ultra |
| Maximum Rated Motor Current Adjustment | 12 A |
| Compatible Manufacturer Part Number | LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380 |
| Compatible Manufacturer Model Number | LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380 |
| For Use with Mfr. Model Number | LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380 |
| For Use With Mfr. Model Number | LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380 |
| Motor Power Kw | 2.2 kW 400 to 440 V AC 50/60 Hz 1 phase |
| Resistance To Electrostatic Discharge | 8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2 |
| Width | 45 mm |
| Ambient Air Temperature For Storage | -40-85ΓΒ°C |
| Depth | 60 mm |
| Operating Altitude | 6561.68 ft (2000 m) |
| Fire Resistance | 960ΓΒ°C parts supporting live components IEC 60695-2-12 || 650ΓΒ°C IEC 60695-2-12 |
| Height | 66 mm |
| Immunity To Voltage Dips | 70 % / 500 ms IEC 61000-4-11 |
| [Ue] Rated Operational Voltage | 690 V AC |
| Immunity To Microbreaks | 3 ms |
| Immunity To Radioelectric Fields | 10 V IEC 61000-4-6 |
| Operating Time | 35 ms opening with LUB12 control circuit || 35 ms opening with LUB32 control circuit || 35 ms opening with LUB38 control circuit || 50 ms closing with LUB12 control circuit || 50 ms closing with LUB32 control circuit || 50 ms closing with LUB38 control circuit |
| Range | TeSys |
| Product Compatibility | power base LUB12 || power base LUB32 || power base LUB38 || power base LUB120 || power base LUB320 || power base LUB380 || reversing contactor breaker LU2B12FU || reversing contactor breaker LU2B32FU || reversing contactor breaker LU2B38FU |
| Shock Resistance | 10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27 |
| Tripping Threshold | 14.2 x Ir +/- 20 % |
| Vibration Resistance | 2 gn 5-300 Hz power poles open IEC 60068-2-6 || 4 gn 5-300 Hz power poles closed IEC 60068-2-6 |
| Resistance To Fast Transients | 2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4 |
| Fixing Mode | plug-in front face) |
| Network Frequency | 40 to 60 Hz |
| Product Certifications | CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine |
| [Uc] Control Circuit Voltage | 110 to 240 V AC || 110 to 220 V DC |
| Load Type | single-phase motor |
| Control Circuit Voltage Limits | 88 to 264 V AC 110 to 240 V in operation || 88 to 242 V DC 110 to 220 V in operation || 55 V AC 110 to 240 V drop-out || 55 V DC 110 to 220 V drop-out |
| Resistance To Radiated Fields | 10 V/m 3 IEC 61000-4-3 |
| Thermal Protection Adjustment Range | 3-12 A |
| Ambient Air Temperature For Operation | -25-70ΓΒ°C |
| Main Function Available | Protection against overload and short-circuit; Earth fault protection; Manual reset; Protection against phase failure and phase imbalance |
| Product Name | TeSys Ultra |
| Utilisation Category | AC-43 || AC-41 || AC-44 |
| Thermal Overload Class | class 10 40-60 Hz -25-55ΓΒ°C IEC 60947-6-2 || class 10 40-60 Hz -25-55ΓΒ°C UL 508 |
| Product Or Component Type | advanced control unit |
| Typical Current Consumption | 280 mA 110 to 240 V AC I maximum while closing with LUB12 || 280 mA 110 to 240 V AC I maximum while closing with LUB32 || 280 mA 110 to 240 V AC I maximum while closing with LUB38 || 280 mA 110 to 220 V DC I maximum while closing with LUB12 || 280 mA 110 to 220 V DC I maximum while closing with LUB32 || 280 mA 110 to 220 V DC I maximum while closing with LUB38 || 35 mA 110 to 240 V AC I rms sealed with LUB12 || 25 mA 110 to 240 V AC I rms sealed with LUB32 || 25 mA 110 to 240 V AC I rms sealed with LUB38 || 35 mA 110 to 220 V DC I rms sealed with LUB12 || 25 mA 110 to 220 V DC I rms sealed with LUB32 || 25 mA 110 to 220 V DC I rms sealed with LUB38 |
| Device Application | motor control || motor protection |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947-6-2 |
| Device Short Name | LUCC |
| Reset | manual reset |
| Heat Dissipation | 2-2 W control circuit with LUB12 || 3-3 W control circuit with LUB32 || 3-3 W control circuit with LUB38 |
| Function Available | protection against overload and short-circuit || earth fault protection || manual reset || protection against phase failure and phase imbalance |
| Rated Insulation Voltage | 690 V IEC 60947-6-2; 600 V UL 60947-4-1; 600 V CSA C22.2 No 60947-4-1 |
| Product Specific Application | basic protection and advanced functions, communication |
| Non-Dissipating Shock Wave | 1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2 |
| Compatibility Code | LUCC |
| Protective Treatment | TH IEC 60068 |
| Control Circuit Voltage | 110 to 240 V AC; 110 to 220 V DC |
| [Ui] Rated Insulation Voltage | 690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1 |
| Rated Motor Current Adjustment Range | 3 to 12 A |
| Safe Separation Of Circuit | 400 V SELV between the control and auxiliary circuits IEC 60947-1 || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 |
| Ip Degree Of Protection | IP20 front panel and wired terminals IEC 60947-1 || IP20 other faces IEC 60947-1 || IP40 front panel outside connection zone IEC 60947-1 |
| Country of Origin (subject to change) | France |
| Package Quantity | 1 |
Overload Module, 3 to 12A, Class 10, 3P, Schneider Electric, Mfr#: LUCC12FU
$200.99
Free shipping will be applied on orders over $50
Overload Module, Maximum Rated Motor Current Adjustment 12 A, Minumum Rated Motor Current Adjustment 3 A, Coil Voltage 110-240V AC/DC, Compatible with Series TeSys Ultra, Terminal Connection Type Wire Leads, Trip Class 10, Phase Single, Maximum Voltage Rating 690V AC, Reset Type Manual, Standards ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed, Compatible with Grainger Part Number 5AB63, 5AB64, 5AB66, 5AB68
9999 in stock
Subtotal:
$200.99
You must be logged in to post a review.
Reviews
There are no reviews yet.