ItemRear Module
Port TypeUSB 2.0, USB-Mini B
Height5.6 in
Width10.4 in
Depth11.8 in
Voltage24V DC
For Use WithHMIS85, Mfr. No. HMIS65
Package Quantity1
UpgradeabilityUpgradeable through digital modules and upgraded components
Relative Humidity5-85 % without condensation
Device Presentationbasic element
Discrete Input Voltage24 V DC sink or source (positive/negative)
Integrated Connection Type1 serial link - RJ45 - RS232/RS485 <= 115.2 kbits/s) || 1 Ethernet TCP/IP - RJ45 || 1 USB 2.0 type mini B || 1 USB 2.0 type A || CANopen master bus - SUB-D 9
Analogue Output Range0...20 mA/4...20 mA > 300 Ohm)open-circuit || -10...10 V/0...10 V > 2 kOhm)short-circuit
Shock Resistance147 m/s? 11 ms on DIN rail)IEC 60068-2-27 || 294 m/s? 6 ms on panel mounting)IEC 60068-2-27
Discrete Input Number2 fast input (normal mode) IEC 61131-2 Type 1 || 6 digital input IEC 61131-2 Type 1
Discrete Input Current7.83 mA fast input || 5 mA digital
Electromagnetic Compatibilityelectrostatic discharge immunity test 8 kV air discharge) IEC 61000-4-2 || electrostatic discharge immunity test 6 kV contact discharge) IEC 61000-4-2 || susceptibility to electromagnetic fields 10 V/m 80 MHz...3 GHz) IEC 61000-4-3 || electrical fast transient/burst immunity test 2 kV power lines) IEC 61000-4-4 || electrical fast transient/burst immunity test 1 kV between analogue I/O and operating voltage) IEC 61000-4-4 || electrical fast transient/burst immunity test 2 kV relay wires) IEC 61000-4-4 || electrical fast transient/burst immunity test 1 kV Ethernet line) IEC 61000-4-4 || electrical fast transient/burst immunity test 1 kV COM line) IEC 61000-4-4 || electrical fast transient/burst immunity test 1 kV CAN line) IEC 61000-4-4 || surge immunity test 2 kV power supply (common mode)) IEC 61000-4-5 || surge immunity test 1 kV power supply (differential mode)) IEC 61000-4-5 || surge immunity test 1 kV common mode digital I/O) IEC 61000-4-5 || surge immunity test 0.5 kV differential mode digital I/O) IEC 61000-4-5 || conducted RF disturbances 10 V 0.15...80 MHz) IEC 61000-4-6 || conducted emission 150 kHz...30 MHz EN 55011 || radiated emission 30 MHz...1 GHz EN 55011
Maximum Input Frequency100 kHz fast input (encoder mode) A/B || 100 kHz fast input single phase || 100 kHz fast input pulse/direction
Ambient Air Temperature For Operation0-50°C
Realtime Clockbuilt-in
Input/Output Number2 fast input FI0...FI1 || 2 fast output FQ0...FQ1 || 6 digital input DI0...DI5 || 6 digital output DQ0...DQ5
Product CertificationscULus 508 || cUL 1604 Class 1 Division 2 || C-tick || cULus CSA 22-2 No 142 || GOST || KCC || UKCA || UKEX
Isolation Between Channels And Internal Logic500 V DC
Product Or Component Typecontroller
Local Signallingno indicator
Analogue Output Number2 resistive load 12 bits + sign
Absolute Accuracy Error+/- 0.1 % of full scale cyclic ratio 1...99% fast output (PWM or PTO mode) || 1 % of full scale cyclic ratio 1...99% fast output (PWM or PTO mode) || +/- 5 % of full scale cyclic ratio 10...90% fast output (PWM or PTO mode) || +/- 10 % of full scale cyclic ratio 20...80% fast output (PWM or PTO mode) || +/- 15 % of full scale cyclic ratio 30...70% fast output (PWM or PTO mode)
Power Consumption In W15 W
Sensor Power Supply15-28.8 V DC >= 15 V >= 5 mA <= 5 V <= 1.5 mA || 15-28.8 V DC >= 15 V >= 2.5 mA <= 5 V <= 1 mA
Fixing Modeby 1 nut ? 22 mm 1...6 mm thick panel
Discrete Output Number2 fast output (normal mode) source || 6 digital output source
StandardsUL 508 || FCC Class A || EN 61131-2 || CSA C22.2 No 213 Class I Division 2 || ANSI/ISA 12-12-01 || IEC 61000-6-2
Storage Altitude0-10000 m
Memory Descriptionflash NAND, 128 MB || internal data storage FRAM, 128 kB || application run DRAM, 128 MB
Processor Frequency333 MHz
Discrete Output Voltage24 V DC 19.2...28.8 V)transistor || 24 V DC 5...30 V)relay || 220 V AC 100...250 V)relay
Operating Altitude<= 6561.68 ft (2000 m)
Immunity To Microbreaks10 ms
Nema Degree Of ProtectionNEMA 4X front panel
Analogue Input TypeRTD - 200...600°C 16 bitsPt 100/Pt 1000 || RTD - 50...200°C 16 bitsNi 100/Ni 1000 || RTD - 200...760°C 16 bits thermocouple J) || RTD - 240...1370°C 16 bits thermocouple K) || RTD 0...1600°C 16 bits thermocouple R) || RTD 200...1800°C 16 bits thermocouple B) || RTD 0...1600°C 16 bits thermocouple S) || RTD - 200...400°C 16 bits thermocouple T) || RTD - 200...900°C 16 bits thermocouple E) || RTD - 200...1300°C 16 bits thermocouple N)
Ambient Air Temperature For Storage-20-60°C
Discrete Output Current2 A 4 A)5 ms opening contact digital output || 2 A 4 A)2 ms closing contact digital output || 300 mA2 ms fast output (normal mode) || 50 mA2 ms fast output (PWM or PTO mode)
Maximum Cable Distance Between Devicesshielded cable <10 m fast input || shielded cable <100 m digital input || unshielded cable <50 m digital input
[Us] Rated Supply Voltage24 V 20.4-28.8 V)DC
Inrush Current30 A
Number Of Common Point1 fast input (HSC mode) || 1 digital input
Configurable Filtering Time0 ms no filter none) || 0.004...0.04 ms bounce filter latch/event and cumulative filter by step Nx0.5ms (64>=N>=2)) || 3...12 ms integrator none/run/stop)
Software DesignationSoMachine
Environmental Characteristiccorrosive gas free
Ip Degree Of ProtectionIP20 IEC 60529 rear panel) || IP65 IEC 60529 front panel)
Maximum Pressure800...1114 hPa
Overvoltage Protectionwith
Vibration Resistance+/- 3.5 mm 5-9 Hz) IEC 60068-2-6 || 1 gn 9-150 Hz) IEC 60068-2-6
Number Of Pageslimited by internal memory capacity
Processor NameCPU RISC
Downloadable ProtocolsModbus || CANopen || Modbus TCP/IP
Analogue Input Number2 analog input || 2 RTDs
Pollution Degree2 IEC 60664
Enclosure MaterialPC/PBT
Analogue Input Range0...20 mA/4...20 mA 12 bits 250 Ohm +/- 1 %) || -10...+10 V or 0...10 V 12 bits + sign >= 1 MOhm
Operating SystemHarmony
Input Impedance2.81 kOhm || 4.7 kOhm
Connection Pitch3.5 mm
Insulation Resistance> 10 MOhm between the I/O and internal logic || > 10 MOhm between power supply and earth
Supplyexternal source
Maximum Output Frequency100 kHz fast output (PTO mode) || 1 kHz fast output (PWM mode)
MarkingCE
Rated Supply Voltage24 V 20.4 to 28.8 V)DC
Country of Origin (subject to change)China
TAGS:
#Rear Module
#Controller
#24VDC
#SCHNEIDER ELECTRIC
#Mfr HMISBC
#SCHNEIDER ELECTRIC
#GRG2009852
#mfr:HMISBC
#part number:HMISBC
#pn:HMISBC
#part code:HMISBC
#item number:HMISBC
#product code:HMISBC
#manufacturer number:HMISBC
#manufacturers part number:HMISBC
#mfn:HMISBC

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!