IEC Magnetic Contactor, 3 Poles, 120 V AC, 80 A, SCHNEIDER ELECTRIC, Mfr# LC2D80G7

$987,99

Free shipping will be applied on orders over $50

IEC Magnetic Contactor

9999 in stock

Must order in multiples of 1
Subtotal:
$987.99
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC2D80G7
Availability: Ships in 5 days
SKU: GRG0568517 Category:
Full Load Amps-Inductive80 A
ItemIEC Magnetic Contactor
ActionReversing
Full Load Amps-Resistive125 A
Number of Poles3
Coil Volts120 V AC
Height127 mm
HP @ 1 Phase - 240V15 hp
HP @ 3 Phase - 208V20 hp
Width182 mm
HP @ 3 Phase - 575V60 hp
HP @ 3 Phase - 240V25 hp
Depth158 mm
HP @ 3 Phase - 480V60 hp
Aux. Contact Configuration1NO/1NC
SeriesLC2D
StandardsCSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, UL, CSA, RINA, GOST, CCC, DNV, LROS, GL, BV, UKCA, TH IEC 60068-2-30
ApplicationMotor Control, Resistive Load
FeaturesWithout Built-In Suppressor Module, Preassembled with Reversing Power Busbar
Max. Operating Watts22 kW (at 220 to 230V AC 50 Hz), 37 kW (at 380 to 400V AC 50 Hz), 45 kW (at 415 to 440V AC 50 Hz), 55 kW (at 500V AC 50 Hz), 45 kW (at 660 to 690V AC 50 Hz)
Rated Short-Time Withstand Current135 A (at 40°C for 10 min Power Circuit), 320 A (at 40°C for 1 min Power Circuit), 640 A (at 40°C for 10 s Power Circuit), 990 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Max. Temperature850°C
Rated Voltage690V AC, 300V DC
IP RatingIP20
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Thermal Amperage10 A (at 60°C Signalling Circuit), 125 A (at 60°C Power Circuit)
Tightening Torque1.2 Nm (Control Circuit), 12 Nm (Power Circuit)
Overvoltage CategoryCAT III
Non-Overlap Time1.5 ms
Impedance0.8 mOhm
Fire RatingUL 94 V1
Operating Speed3600 cycles per hr
Includes Protective CoverYes
Net Weight3.2 kg
Mounts OnPlate, Rail
Hold VA26 VA
Mechanical Durability4 Mcycles
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Operating Time20 to 35 ms (Closing), 6 to 20 ms (Opening)
Rated Insulation Volts600/1000V (Power Circuit), 600/690V (Signalling Circuit)
Watts Loss6 to 10W
Fuse Amps10 A (Signalling Circuit), 200 A (Type 1 Power Circuit), 160 A (Type 2 Power Circuit)
Shock Resistance10 G for 11 ms (Contactor Closed), 8 G for 11 ms (Contactor Open)
Working HeightUp to 9842.52 ft
Switching Current5 mA (Signalling Circuit)
Rated Breaking Capacity1100 A @ 440V
Impulse Withstand Voltage8 kV
Switching Voltage17 V (Signalling Circuit)
Inrush VA245 VA
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1100 A @ 440V (Power Circuit)
Electrical Durability0.8 Mcycles (125 A, AC-1, Less than 440 V), 1.5 Mcycles (80 A, AC-3, Less than 440 V), 1.5 Mcycles (80 A, AC-3e, Less than 440 V)
Electrical ConnectionScrew Clamp Terminals
Control Circuit Voltage LimitsDrop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (-40 to 55°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 55°C 60 Hz), 1 to 1.1 Uc (at 55 to 70°C 50/60 Hz)
Signalling Circuit Frequency25 to 400 Hz
Vibration Resistance3 G (Contactor Closed), 2 G (Contactor Open)
Average Impedance0.8 mOhm - Ith 125 A 50 Hz for power circuit
Poles Description3P
IP Degree Of ProtectionIP20 front face IEC 60529
Mechanical RobustnessVibrations contactor open2 Gn, 5 to 300 Hz, Shocks contactor open8 Gn for 11 ms, Vibrations contactor closed3 Gn, 5 to 300 Hz, Shocks contactor closed10 Gn for 11 ms
Device PresentationPreassembled with reversing power busbar
Inrush Power in VA245 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 245 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Motor Power KW22 kW at 220 to 230 V AC 50 Hz, 37 kW at 380 to 400 V AC 50 Hz, 45 kW at 415 to 440 V AC 50 Hz, 55 kW at 500 V AC 50 Hz, 45 kW at 660 to 690 V AC 50 Hz
Minimum Switching Voltage17 V for signalling circuit
Operating Altitude0 to 9842.52 ft (0 to 3000 m)
Rated Operational Current125 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 80 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 80 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit, 55 A (at Less than 140°F (60°C)) at Less than or Equal to 400 V AC AC-4 for power circuit
Product Or Component TypeReversing contactor
IRMS Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 1100 A at 440 V for power circuit conforming to IEC 60947
Control Circuit TypeAC 50/60 Hz
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Power Dissipation Per Pole12.5 W AC-1, 5.1 W AC-3, 5.1 W AC-3e
Auxiliary Contact Composition1 NO + 1 NC
Fire Resistance1562°F (850°C) IEC 60695-2-1
Minimum Switching Current5 mA for signalling circuit
Contactor ApplicationResistive load, Motor control
Hold-In Power Consumption in VA26 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 26 VA 50 Hz cos phi 0.3 (at 68°F (20°C))
Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
Front CoverWith
Maximum Operating Rate3600 cyc/h 140°F (60°C)
Rated Impulse Withstand Voltage8 kV IEC 60947
Utilisation CategoryAC-1, AC-3, AC-3e, AC-4
Mounting SupportPlate, Rail
Heat Dissipation6 to 10 W 50/60 Hz
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1, 200 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 160 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Protective TreatmentTH IEC 60068-2-30
Ambient Air Temperature For Operation-40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating
Conventional Free Air Thermal Current10 A (at 140°F (60°C)) for signalling circuit, 125 A (at 140°F (60°C)) for power circuit
Connections - TerminalsControl circuit screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?)flexible without cable end, Control circuit screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?)flexible without cable end, Control circuit screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?)flexible with cable end, Control circuit screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?)solid, Control circuit screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?)solid, Control circuit screw clamp terminals 1 0.00 to 0.00 in? (1 to 2.5 mm?)flexible with cable end, Power circuit connector 1 0.01 to 0.08 in? (4 to 50 mm?)flexible without cable end, Power circuit connector 2 0.01 to 0.04 in? (4 to 25 mm?)flexible without cable end, Power circuit connector 1 0.01 to 0.08 in? (4 to 50 mm?)flexible with cable end, Power circuit connector 2 0.01 to 0.02 in? (4 to 16 mm?)flexible with cable end, Power circuit connector 1 0.01 to 0.08 in? (4 to 50 mm?)solid, Power circuit connector 2 0.01 to 0.04 in? (4 to 25 mm?)solid
Ambient Air Temperature For Storage-76 to 176°F (-60 to 80°C)
Flame RetardanceV1 conforming to UL 94
Motor Power HP20 hp at 200/208 V AC 60 Hz for 3 phase motors, 7.5 hp at 115 V AC 60 Hz for 1 phase motors, 15 hp at 230/240 V AC 60 Hz for 1 phase motors, 25 hp at 230/240 V AC 60 Hz for 3 phase motors, 60 hp at 460/480 V AC 60 Hz for 3 phase motors, 60 hp at 575/600 V AC 60 Hz for 3 phase motors
Control Circuit Voltage120 V AC 50/60 Hz
Interlocking TypeMechanical
Rated Operational VoltagePower circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC
Coil TechnologyWithout built-in suppressor module
Climatic WithstandIACS E10
Product CertificationsUL, CSA, RINA, GOST, CCC, DNV, LROS (Lloyds register of shipping), GL, BV, UKCA
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Product NameTeSys Deca
Rated Insulation VoltagePower circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL, Power circuit 1000 V IEC 60947-4-1
Pollution Degree3
Power Pole Contact Composition3 NO
Rated Short Time Withstand Current135 A 104°F (40°C) - 10 min for power circuit, 320 A 104°F (40°C) - 1 min for power circuit, 640 A 104°F (40°C) - 10 s for power circuit, 990 A 104°F (40°C) - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Country of Origin (subject to change)Czechia
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#120 V AC
#80 A
#SCHNEIDER ELECTRIC
#Mfr LC2D80G7
#SCHNEIDER ELECTRIC
#GRG0568517
#mfr:LC2D80G7
#part number:LC2D80G7
#pn:LC2D80G7
#part code:LC2D80G7
#item number:LC2D80G7
#product code:LC2D80G7
#manufacturer number:LC2D80G7
#manufacturers part number:LC2D80G7
#mfn:LC2D80G7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!