Full Load Amps-Inductive | 9 A |
Item | IEC Magnetic Contactor |
Action | Reversing |
Full Load Amps-Resistive | 25 A |
Number of Poles | 3 |
Coil Volts | 24 V AC |
Reversing | Yes |
HP @ 1 Phase - 120V | 1/2 hp |
HP @ 1 Phase - 240V | 1 hp |
Height | 3.03 in |
HP @ 3 Phase - 208V | 2 hp |
Width | 3.54 in |
Depth | 3.39 in |
HP @ 3 Phase - 240V | 5 hp |
HP @ 3 Phase - 575V | 7 1/2 hp |
HP @ 3 Phase - 480V | 5 hp |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
NEMA Size | Not Applicable |
Series | TeSys Deca |
Frame / Series / Class / Code | TeSys |
Auxiliary Contact Form | 1NO/1NC |
Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
Switching Voltage | 17 V (Signalling Circuit) |
Net Weight | 0.687 kg |
Watts Loss | 2 to 3W |
Tightening Torque | 1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit) |
Rated Insulation Volts | 600/690V |
Features | Without Built-In Suppressor Module, Preassembled with Reversing Power Busbar |
Inrush VA | 70 VA |
Electrical Durability | 0.6 Mcycles (25 A, AC-1, Less than 440 V), 2 Mcycles (9 A, AC-3, Less than 440 V) |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
Max. Operating Watts | 2.2 kW (at 220 to 230V AC 50 Hz), 4 kW (at 380 to 400V AC 50 Hz), 4 kW (at 415 to 440V AC 50 Hz), 5.5 kW (at 500V AC 50 Hz), 5.5 kW (at 660 to 690V AC 50 Hz) |
Rated Voltage | 690V AC, 300V DC |
Rated Making Capacity | 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit) |
Rated Breaking Capacity | 250 A @ 440V |
Fire Rating | UL 94 V1 |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Non-Overlap Time | 1.5 ms |
Max. Temperature | 850°C |
Includes Protective Cover | Yes |
Fuse Amps | 25 A (Type 1 Power Circuit), 20 A (Type 2 Power Circuit), 10 A (Signalling Circuit) |
Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
Switching Current | 5 mA (Signalling Circuit) |
Mounts On | Plate, Rail |
IP Rating | IP20 |
Impulse Withstand Voltage | 6 kV |
Operating Time | 12 to 22 ms (Closing), 4 to 19 ms (Opening) |
Mechanical Durability | 15 Mcycles |
Impedance | 2.5 mOhm |
Electrical Connection | Faston Terminals |
Signalling Circuit Frequency | 25 to 400 Hz |
Operating Speed | 3600 cycles per hr |
Application | Motor Control, Resistive Load |
Rated Short-Time Withstand Current | 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Overvoltage Category | CAT III |
Working Height | Up to 9842.52 ft |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 25 A (at 60°C Power Circuit) |
NEMA Enclosure Rating | No Enclosure |
Number of Normally Open Main Contacts | 3 |
Overall Height | 3.03 in |
Full Load Current - Inductive | 9 A |
Overall Width | 3.54 in |
Mechanical Operating Durability | 15,000,000 |
Horsepower @ Three Phase - 600V AC | 7 1/2 hp |
Horsepower @ Three Phase - 480V AC | 5 hp |
Electrical Operating Durability | 2,000,000, 600,000 |
Number of Auxillary Contacts | 2 |
Maximum Operating Temperature | 140 Degrees F |
Embedded Surge Suppressor | No |
Maximum Voltage Rating | 690V AC |
Horsepower @ Single Phase - 120V AC | 1/2 hp |
NEMA Enclosure Material | Not Applicable |
Frequency | 50/60 Hz |
Full Load Current - Resistive | 25 A |
Reversing Capability | Reversing |
Mounting Style | DIN Rail, Plate |
Includes Auxiliary Contacts | Yes |
Contactor Style | IEC |
Horsepower @ Three Phase - 240V AC | 2 hp |
Terminal Connection Type | Quick-Disconnect Terminals |
Resistance Properties | Fire Resistant, Insulation Resistant |
Horsepower @ Single Phase - 240V AC | 1 hp |
Overall Depth | 3.39 in |
Coil Voltage | 24V AC |
Horsepower @ Three Phase - 208V AC | 2 hp |
Minimum Operating Temperature | -40 Degrees F |
Utilisation Category | AC-3, AC-1 |
Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC |
Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1 |
Rated Short Time Withstand Current | 30 A 104°F (40°C) - 10 min for power circuit, 61 A 104°F (40°C) - 1 min for power circuit, 105 A 104°F (40°C) - 10 s for power circuit, 210 A 104°F (40°C) - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit |
Conventional Free Air Thermal Current | 10 A (at 140°F (60°C)) for signalling circuit, 25 A (at 140°F (60°C)) for power circuit |
Hold-In Power Consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C)) |
Ambient Air Temperature For Storage | -76 to 176°F (-60 to 80°C) |
Power Pole Contact Composition | 3 NO |
Rated Insulation Voltage | Power circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL |
Front Cover | With |
Average Impedance | 2.5 mOhm - Ith 25 A 50 Hz for power circuit |
Coil Technology | Without built-in suppressor module |
IRMS Rated Making Capacity | 250 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1 |
Rated Operational Current | 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit |
Minimum Switching Voltage | 17 V for signalling circuit |
Protective Treatment | TH IEC 60068-2-30 |
Climatic Withstand | IACS E10, IEC 60947-1 Annex Q category D |
Minimum Switching Current | 5 mA for signalling circuit |
Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
Interlocking Type | Mechanical |
Control Circuit Type | AC 50/60 Hz |
Power Dissipation Per Pole | 0.2 W AC-3, 1.56 W AC-1 |
Pollution Degree | 3 |
Ambient Air Temperature For Operation | -40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating |
Operating Altitude | 0 to 9842.52 ft (0 to 3000 m) |
Motor Power HP | 0.5 hp at 115 V AC 60 Hz for 1 phase motors, 1 hp at 230/240 V AC 60 Hz for 1 phase motors, 2 hp at 200/208 V AC 60 Hz for 3 phase motors, 2 hp at 230/240 V AC 60 Hz for 3 phase motors, 5 hp at 460/480 V AC 60 Hz for 3 phase motors, 7.5 hp at 575/600 V AC 60 Hz for 3 phase motors |
Auxiliary Contact Composition | 1 NO + 1 NC |
Flame Retardance | V1 conforming to UL 94 |
Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
Motor Power KW | 2.2 kW at 220 to 230 V AC 50 Hz, 4 kW at 380 to 400 V AC 50 Hz, 4 kW at 415 to 440 V AC 50 Hz, 5.5 kW at 500 V AC 50 Hz, 5.5 kW at 660 to 690 V AC 50 Hz |
Product Name | TeSys D, TeSys Deca |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Device Presentation | Preassembled with reversing power busbar |
Maximum Operating Rate | 3600 cyc/h 140°F (60°C) |
Inrush Power in VA | 70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C)) |
Connections - Terminals | Power circuit Faston terminals 2, Control circuit Faston terminals 1 |
Product Certifications | DNV, CSA, CCC, UL, GL, LROS (Lloyds register of shipping), BV, RINA, GOST, UKCA |
Heat Dissipation | 2 to 3 W 50/60 Hz |
IP Degree Of Protection | IP20 front face IEC 60529 |
Product Or Component Type | Reversing contactor |
Contactor Application | Motor control, Resistive load |
Control Circuit Voltage | 24 V AC 50/60 Hz |
Mechanical Robustness | Vibrations contactor open2 Gn, 5 to 300 Hz, Vibrations contactor closed4 Gn, 5 to 300 Hz, Shocks contactor open10 Gn for 11 ms, Shocks contactor closed15 Gn for 11 ms |
Poles Description | 3P |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
Associated Fuse Rating | 25 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 20 A gG at Less than or Equal to 690 V coordination type 2 for power circuit, 10 A gG for signalling circuit conforming to IEC 60947-5-1 |
Mounting Support | Plate, Rail |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 24 V AC, 9 A, Reversing: Yes, SCHNEIDER ELECTRIC, Mfr# LC2D099B7
$306,99
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V AC, Number of Poles 3, Full Load Current - Inductive 9 A, Full Load Current - Resistive 25 A, Reversing Capability Reversing, Overall Height 3.03 in, Overall Width 3.54 in, Terminal Connection Type Quick-Disconnect Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$306.99
You must be logged in to post a review.
Reviews
There are no reviews yet.