Item
Safety Interlock Switch
AC Contact Rating
6 A @ 300 V
DC Contact Rating
0.55 A @ 300 V
Style
Elbowed Lever Operated
Connection Type
1/2 in NPT Conduit
Description/Special Features
Dust Tight and Corrosion Resistant (Indoor/Outdoor) Enclosure, Water Tight
Operating Temp. Range
-13 Degrees to 158 Degrees F
Standards
BG, CSA C22.2 No 14, EN 1088/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, EN/IEC 60947-5-4, EN/ISO 12100, UL 508
Operating Force
0.18 ft-lb
Electrical Connection
1/2 in NPT Conduit
Head Type
turret head rotary lever
Vibration Resistance
50 gn 10-500 Hz)IEC 60068-2-6
Mechanical Durability
1000000 cycles
Shock Resistance
50 gn 11 ms IEC 60068-2-27
Mechanical Operating Durability
1,000,000
NEMA Enclosure Rating
12, 4, 4X
Operating Temperature - Minimum
-13 Degrees F
Resistance Properties
Corrosion Resistant, Dust Resistant, Shock Resistant, Vibration Resistant, Watertight
Circuitry Action
Slow Action
Operating Torque
2.16 in-lb
Actuating Key Type
Elbowed
Operating Temperature - Maximum
158 Degrees F
Manufacturer Warranty Length
18 mo
Cable Outer Diameter
7-10 mm
Insulation
double insulated
[Ui] Rated Insulation Voltage
300 VUL 508 || 300 VCSA C22.2 No 14 || 500 V 3)EN/IEC 60947-1
Clamping Connection Capacity
1 x 0.5...2 x 1.5 mm² with or without cable end
Enclosure Material
polyamide PA66 fibre glass impregnated
Ip Degree Of Protection
IP67 conforming to IEC 60529
Operator Direction Information
centred
Safety Level
can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired IEC 61508
Product Certifications
UL || BG || CSA
Lever Material
stainless steel
Product Or Component Type
guard switch
Ambient Air Temperature For Storage
-40-70°C
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-5-1
Contacts Type And Composition
1 NC + 1 NO
Electrical Shock Protection Class
class II EN/IEC 61140
Protective Treatment
TC || TH
Contact Operation
slow-break, break before make
Positive Opening Minimum Torque
0.25 N.m
Short-Circuit Protection
10 A cartridge fuse gG (gl)
Positive Opening
with NC contact
Cable Entry
1 entry tapped 1/2
Maximum Resistance Across Terminals
30 mOhm EN/IEC 60947-5-4
Ambient Air Temperature For Operation
-25-70°C
Minimum Torque For Tripping
0.1 N.m
Contact Code Designation
A300, AC-15 (Ue = 120 V, Ie = 6 A)EN/IEC 60947-5-1 || A300, AC-15 (Ue = 240 V, Ie = 3 A)EN/IEC 60947-5-1 || Q300, DC-13 (Ue = 125 V, Ie = 0.55 A)EN/IEC 60947-5-1 || Q300, DC-13 (Ue = 250 V, Ie = 0.27 A)EN/IEC 60947-5-1
[Ithe] Conventional Enclosed Thermal Current
10A
Type Of Operator
elbowed flush lever
Country of Origin (subject to change)
Multiple