Item
Safety Interlock Switch
AC Contact Rating
0.75 A @ 240 V, 1.5 A @ 120 V
DC Contact Rating
0.27 A @ 250 V, 0.55 A @ 125 V
Connection Type
6.6 ft Dead End Cable
Operating Temp. Range
-13 Degrees to 158 Degrees F
Standards
CSA C22.2 No 14, EN 1088/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, EN/ISO 12100, UL 508
Description/Special Features
Dust Tight and Corrosion Resistant (Indoor/Outdoor) Enclosure, Water Tight
Actuator Length
Key Dependent
Electrical Connection
6.6 ft Dead End Cable
Mechanical Durability
1000000 cycles
Vibration Resistance
6 gn 10-55 Hz)IEC 60068-2-6
Shock Resistance
50 gn 11 ms IEC 60068-2-27
Head Type
key operated fixed head
Operating Temperature - Maximum
158 Degrees F
Actuating Key Type
Pivoting, Flat
Manufacturer Warranty Length
18 mo
NEMA Enclosure Rating
12, 4, 4X
Operating Temperature - Minimum
-13 Degrees F
Mechanical Operating Durability
1,000,000
Circuitry Action
Slow Action
Resistance Properties
Corrosion Resistant, Dust Resistant, Shock Resistant, Vibration Resistant, Watertight
Minimum Actuator Force For Extraction
8 N
[Ui] Rated Insulation Voltage
300 VUL 508 || 500 VEN/IEC 60947-1 || 300 VCSA C22.2 No 14
Minimum Actuation Speed
0.05 m/s
Product Certifications
UL || cUL || CSA
Ambient Air Temperature For Operation
-25-70°C
Contact Operation
slow-break, break before make
Short-Circuit Protection
10 A cartridge fuse gG (gl)
Product Or Component Type
safety switch
Contacts Type And Composition
2 NC + 1 NO
Ip Degree Of Protection
IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Ambient Air Temperature For Storage
-25-80°C
Actuator Forcible Withdrawal Rtc
8 N
[Ie] Rated Operational Current
0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.75 A 240 V, AC-15, C300 EN/IEC 60947-5-1 || 1.5 A 120 V, AC-15, C300 EN/IEC 60947-5-1
Cable Composition
6 x 0.5 mm²
Maximum Actuation Speed
1.5 m/s
[Ithe] Conventional Enclosed Thermal Current
2.5 A
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-5-1
Safety Level
can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Electrical Shock Protection Class
class II EN/IEC 61140
Maximum Operating Rate
20 cyc/mn for maximum durability
Insulation
double insulated
Country of Origin (subject to change)
Japan