Actuator Length
Key Dependent
AC Contact Rating
4 A @ 300 V
Contact Configuration
3NO/1NC Aux.
For Use With
Mfr. No. XCSZ01, XCSZ02, XCSZ03, XCSZ05
Standards
CSA C22.2 No 14, EN 1088/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, EN/IEC 62061, EN/ISO 13849-1, UL 508
Item
Safety Interlock Switch
DC Contact Rating
3 A @ 300 V
Environmental Protection
IP67
Connection Type
1/2 in NPT Conduit
Description/Special Features
Dust Tight and Corrosion Resistant (Indoor/Outdoor) Enclosure, Water Tight
Operating Temp. Range
-13 Degrees to 158 Degrees F
Mechanical Operating Durability
30,000
NEMA Enclosure Rating
12, 4, 4X
Resistance Properties
Corrosion Resistant, Dust Resistant, Shock Resistant, Vibration Resistant, Watertight
Circuitry Action
Slow Action
Electrical Connection
1/2 in NPT Conduit
Operating Temperature - Maximum
158 Degrees F
Manufacturer Warranty Length
18 mo
Actuating Key Type
Pivoting, Flat
Operating Temperature - Minimum
-13 Degrees F
Head Type
key operated turret head
Positive Opening
with NC contact
Safety Level
can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 EN/IEC 61508
[Ui] Rated Insulation Voltage
300 VUL 508 || 300 VCSA C22.2 No 14 || 250 V 3)EN/IEC 60947-1
Electrical Shock Protection Class
class I EN/IEC 61140
Maximum Actuator Forcible Withdrawal Rtc
3000 N
Product Or Component Type
safety switch
Signalling Circuit Type
AC/DC
Cable Entry
3 entries tapped 1/2
Resistance To Mechanical Impact
9.6 J against the partition || 6.4 J without partition
Ambient Air Temperature For Storage
-40-70°C
[Ie] Rated Operational Current
0.55 A 24 V, DC-13, R300 EN/IEC 60947-5-1 || 0.75 A 240 V, AC-15, C300 EN/IEC 60947-5-1
Minimum Switching Voltage
17 V
Shock Resistance
10 gn 11 ms IEC 60068-2-27
Ambient Air Temperature For Operation
-25-60°C
[Ithe] Conventional Enclosed Thermal Current
4A
Contact Operation
slow-break, break before make
Mechanical Durability
30000 cycles
Minimum Actuation Speed
0.01 m/s
Maximum Actuation Speed
0.5 m/s
Vibration Resistance
5 gn 10-500 Hz)IEC 60068-2-6
Local Signalling
for actuator withdrawn 1 LED (orange) || for actuator inserted and locked 1 LED (green)
Contacts Type And Composition
2 NC + 1 NO
[Uimp] Rated Impulse Withstand Voltage
4 kV EN/IEC 60947-5-1
[Us] Rated Supply Voltage
24 V - 15...10 %
Maximum Load Current
u003c= 15 A
Minimum Switching Current
10 mA at 20°C
Solenoid Contacts Type And Composition
2 NC + 1 NO slow-break, break before make)
Product Certifications
UL || CSA || TUV
Short-Circuit Protection
4 A cartridge fuse gG (gl) || 6 A fast blow
Signalling Circuit Voltage
24 V
Ip Degree Of Protection
IP66 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Maximum Operating Rate
10 cyc/mn for maximum durability
Electromagnet Interlocking
by mushroom head push-button turn to release for escape release || locking on de-energisation and unlocking on energisation of solenoid
Minimum Actuator Force For Extraction
20 N
Country of Origin (subject to change)
Indonesia