Center Line Pipe Center Size
1 3/4 in
Electrical Connections
1/2
Valve Design
3-Way/2-Position
Valve Configuration
Normally Closed
Body Material - Valves
Brass
Max. Fluid Temp.
200 Degrees F
Coefficient of Volume
0.12
Environmental Rating - Valves
Indoor, Outdoor
Min. Operating Pressure Differential
0 psi
Media
Air/Inert Gas, Light Oil and Water
Valve Ways and Positions
3-Way/2-Position
Seal Material - Valves
NBR
Max. Operating Pressure Differential Light Oil
110 psi
Max. Operating Pressure Differential Air/Inert Gas
110 psi
Coil Enclosure
Watertight No Junction Box
Max. Operating Pressure Differential Water
110 psi
NEMA Rating
1, 2, 3, 3S, 4, 4X
Operation Type
Direct Acting
Standards
ATEX, CSA, IIECEx, UL Listed
Application
Analytical and Diagnostic Equipment, Dust Collector Systems, Life Sciences, Metal Stamping, Press Room
Operating Pressure Differential Fuel Gas - Minimum
Not Applicable
Fluid Temperature - Maximum
200 Degrees F
Operating Pressure Differential Hot Water - Minimum
Not Applicable
Operating Pressure Differential - Minimum
0 psi
Operating Pressure Differential Liquid CO2 - Minimum
Not Applicable
Operating Pressure Differential Fuel Oil - Minimum
Not Applicable
Inlet Connection Type
BSPP
Operating Pressure Differential Hot Water - Maximum
Not Rated
Coefficient of Volume (Cv)
0.12
Operating Pressure Differential Light Oil - Maximum
110 psi
Operating Pressure Differential Cryogenic Fluid - Maximum
Not Applicable
For Media
Air, Inert Gases, Light Oil, Water
Operating Pressure Differential Water - Maximum
110 psi
Operating Pressure Differential Fuel Oil - Maximum
Not Applicable
Operating Pressure Differential Light Oil - Minimum
0 psi
Mounting Orientation
Horizontal or Vertical
Valve Positions
2-Position
Operating Pressure Differential Air/Inert Gas - Maximum
110 psi
Valve Starting Configuration
Normally Closed
Operating Pressure Differential Natural Gas - Minimum
Not Applicable
Outlet Connection Type
BSPP
Operating Pressure Differential Steam - Minimum
Not Applicable
Operating Pressure Differential Fuel Gas - Maximum
Not Applicable
Operating Pressure Differential Natural Gas - Maximum
Not Applicable
Operating Pressure Differential Steam - Maximum
Not Rated
Operating Pressure Differential Water - Minimum
0 psi
Environmental Rating
Indoor, Outdoor
Operating Pressure Differential Liquid CO2 - Maximum
Not Applicable
Operating Pressure Differential Cryogenic Fluid - Minimum
Not Applicable
NEMA Enclosure Rating
1, 2, 3, 3S, 4, 4X
Operating Pressure Differential Air/Inert Gas - Minimum
0 psi
Country of Origin (subject to change)
Mexico