| Property | Value |
|---|---|
| Item | Overload Module |
| Overload Relay Amp Setting | 8 to 32 A |
| Coil Volts | 24V DC |
| Number of Poles | 3 |
| Features | Earth fault protection; Protection against overload and short-circuit; Manual reset; Protection against phase failure and phase imbalance; Free of Halogen, Mercury u0026 PVC; Resistance to Fire, Electrostatic Discharge, Fast Transients, Radiated Fields, Shock u0026 Vibration |
| Width | 45 mm |
| Hz | 40 to 60 Hz |
| Height | 66 mm |
| Standards | CSA C22.2 No 60947-4-1, EN 60947-6-2, IEC 60947-6-2, REACH, RoHS, UL Listed 60947-4-1 |
| Depth | 60 mm |
| Use With - Contactors and Starters | Mfr. Series LUA1C Contactors |
| Sensing Method | Thermal |
| Separate Mounting | No |
| Body Width - Relay | 1.77 in |
| Body Height - Relay | 2.6 in |
| Body Depth - Relay | 2.36 in |
| Frame / Series / Class / Code | Class 10 |
| Kit Required for Retrofit Mtg. | No |
| Overload Relay Current Range | 8 to 32A |
| Reset Type - Relay | Manual |
| Trip Class - Overload | 10 |
| Item - Relay | IEC Style Overload Relay |
| Overall Height - Relay | 2.6 in |
| Weight | 0.135 kg |
| Operating Voltage | 690V AC |
| Minumum Rated Motor Current Adjustment | 8 A |
| Reset Type | Manual |
| Maximum Voltage Rating | 690V AC |
| Minimum Operating Temperature | -13 Degrees F |
| Compatible with Series | TeSys Ultra |
| Maximum Operating Temperature | 158 Degrees F |
| Phase | Three |
| Trip Class | 10 |
| Coil Voltage | 24V DC |
| Compatible with Manufacturer Model Number | LUB32, LUB38 |
| Maximum Rated Motor Current Adjustment | 32 A |
| Compatible Manufacturer Part Number | LUB32, LUB38 |
| Compatible Manufacturer Model Number | LUB32, LUB38 |
| For Use with Mfr. Model Number | LUB32, LUB38 |
| For Use With Mfr. Model Number | LUB32, LUB38 |
| Control Circuit Voltage | 24 V DC |
| Resistance To Radiated Fields | 9.14 V/m (10 V/m) 3 IEC 61000-4-3 |
| Typical Current Consumption | 220 mA 24 V DC I maximum while closing with LUB32; 220 mA 24 V DC I maximum while closing with LUB38; 80 mA 24 V DC I rms sealed with LUB32; 80 mA 24 V DC I rms sealed with LUB38 |
| Ambient Air Temperature For Storage | -40 to 185ΓΒ°F (-40 to 85ΓΒ°C) |
| Operating Altitude | 6561.68 ft (2000 m) |
| Shock Resistance | 10 gn power poles open IEC 60068-2-27; 15 gn power poles closed IEC 60068-2-27 |
| Rated Operational Voltage | 690 V AC |
| Product Specific Application | Basic protection requirements for motor starters: overload and short-circuit |
| IP Degree Of Protection | IP20 front panel and wired terminals IEC 60947-1; IP20 other faces IEC 60947-1; IP40 front panel outside connection zone IEC 60947-1 |
| Device Application | Motor control; Motor protection |
| Control Circuit Voltage Limits | 20 to 27 V DC 24 V in operation; 14.5 V DC 24 V drop-out |
| Product Certifications | CE; UL; CSA; CCC; EAC; ASEFA; ATEX; Marine |
| Fire Resistance | 1760ΓΒ°F (960ΓΒ°C) parts supporting live components IEC 60695-2-12; 1202ΓΒ°F (650ΓΒ°C) IEC 60695-2-12 |
| Phase Failure Sensitivity | Yes |
| Resistance To Electrostatic Discharge | 8 kV 3 in open air IEC 61000-4-2; 8 kV 4 on contact IEC 61000-4-2 |
| Rated Insulation Voltage | 690 V IEC 60947-6-2; 600 V UL 60947-4-1; 600 V CSA C22.2 No 60947-4-1 |
| Fixing Mode | Plug-in front face) |
| Operating Time | 35 ms opening with LUB32 control circuit; 35 ms opening with LUB38 control circuit; 70 ms closing with LUB32 control circuit; 70 ms closing with LUB38 control circuit |
| Thermal Overload Class | Class 10 40 to 60 Hz -13 to 158ΓΒ°F (-25 to 70ΓΒ°C) IEC 60947-6-2; Class 10 40 to 60 Hz -13 to 158ΓΒ°F (-25 to 70ΓΒ°C) UL 508 |
| Protective Treatment | TH IEC 60068 |
| Immunity To Voltage Dips | 70% / 500 ms IEC 61000-4-11 |
| Utilisation Category | AC-43; AC-44; AC-41 |
| Product Or Component Type | Standard control unit |
| Compatibility Code | LUCA |
| Resistance To Fast Transients | 2 kV 3 serial link IEC 61000-4-4; 4 kV 4 all circuits except for serial link IEC 61000-4-4 |
| Product Compatibility | Power base LUB32; Power base LUB38; Power base LUB320; Power base LUB380; Reversing contactor breaker LU2B32BL; Reversing contactor breaker LU2B38BL |
| Main Function Available | Earth fault protection; Protection against overload and short-circuit; Manual reset; Protection against phase failure and phase imbalance |
| Vibration Resistance | 2 gn 5 to 300 Hz power poles open IEC 60068-2-6; 4 gn 5 to 300 Hz power poles closed IEC 60068-2-6 |
| Safe Separation Of Circuit | 400 V SELV between the control and auxiliary circuits IEC 60947-1; 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 |
| Ambient Air Temperature For Operation | -13 to 158ΓΒ°F (-25 to 70ΓΒ°C) |
| Tripping Threshold | 14.2 x Ir +/- 20% |
| Motor Power KW | 15 kW 400 to 440 V AC 50/60 Hz; 15 kW 500 V AC 50/60 Hz; 18.5 kW 690 V AC 50/60 Hz |
| Heat Dissipation | 3 W control circuit with LUB32; 3 W control circuit with LUB38 |
| Immunity To Radioelectric Fields | 10 V IEC 61000-4-6 |
| Immunity To Microbreaks | 3 ms |
| Load Type | 3-phase motor self-cooled |
| Rated Impulse Withstand Voltage | 6 kV IEC 60947-6-2 |
| Country of Origin (subject to change) | France |
| Package Quantity | 1 |
Overload Module, 24V DC, 3 Poles, Schneider Electric, Mfr#: LUCA32BL
$137.99
Free shipping will be applied on orders over $50
Overload Module, Maximum Rated Motor Current Adjustment 32 A, Minumum Rated Motor Current Adjustment 8 A, Coil Voltage 24V DC, Compatible with Series TeSys Ultra, Trip Class 10, Phase Three, Maximum Voltage Rating 690V AC, Reset Type Manual, Standards CSA C22.2 No 60947-4-1, EN 60947-6-2, IEC 60947-6-2, REACH, RoHS, UL Listed 60947-4-1, Compatible with Grainger Part Number 5AB64, Maximum Operating Temperature 158 Degrees F, Minimum Operating Temperature -13 Degrees F
9999 in stock
Subtotal:
$137.99
You must be logged in to post a review.