TESYS motor starter kit, LC1D09G7 contac, SCHNEIDER ELECTRIC, Mfr# GV2P05KD09G7

$124.99

Free shipping will be applied on orders over $50

TESYS motor starter kit,LC1D09G7 contac

Out of stock

Brand Name: Schneider Electric
Mfr #: GV2P05KD09G7
Availability: Ships in 5 days
SKU: GRG4592199 Category:

Analogues

PropertyValue
ItemTESYS motor starter kit,LC1D09G7 contac
Width45 mm
StandardsNF C 63-650 || VDE 0113 || IEC 60947-1 || VDE 0660 || CSA C22.2 || IEC 60947-4-1 || NF C 63-120 || NF C 79-130 || IEC 60947-2 || EN 60204 || UL 508, CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
Depth86 mm, 97 mm
Height77 mm, 89 mm
Magnetic Tripping Current13-13 A
Associated Fuse Rating10 A gG signalling circuit IEC 60947-5-1 || 25 A gG u003c= 690 V type 1 power circuit || 20 A gG u003c= 690 V type 2 power circuit
Permissible Ambient Air Temperature Around The Device-40-70Β°C at Uc
Power Dissipation Per Pole1.56 W AC-1 || 0.2 W AC-3, 2.5 W
RangeTeSys
Mechanical Durability100000 cycles, 15 Mcycles
Utilisation CategoryAC-3 || AC-1 || AC-4, AC-3 IEC 60947-4-1 || category A IEC 60947-2
Mechanical Robustnessvibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Line Rated Current1A
Control Typerotary knob
Overvoltage CategoryIII
Ambient Air Temperature For Storage-60-80Β°C, -40-80Β°C
Pole Contact Composition3 NO
Control Circuit Voltage Limitsdrop-out 0.3...0.6 Uc AC 50/60 Hz 60Β°C) || operational 0.8...1.1 Uc AC 50 Hz 60Β°C) || operational 0.85...1.1 Uc AC 60 Hz 60Β°C)
Mounting Supportrail || plate
Motor Power Kw2.2 kW 220...230 V AC 50/60 Hz AC-3) || 4 kW 380...400 V AC 50/60 Hz AC-3) || 4 kW 415...440 V AC 50/60 Hz AC-3) || 5.5 kW 500 V AC 50/60 Hz AC-3) || 5.5 kW 660...690 V AC 50/60 Hz AC-3) || 2.2 kW 400 V AC 50/60 Hz AC-4), 0.25-0.25 kW 400/415 V AC 50/60 Hz || 0.55-0.55 kW 690 V AC 50/60 Hz
Phase Failure Sensitivityyes IEC 60947-4-1
Insulation Resistanceu003e 10 MOhm signalling circuit
Maximum Horse Power Rating1 hp 230/240 V at AC 50/60 Hz for 1 phase || 2 hp 200/208 V at AC 50/60 Hz for 3 phase || 2 hp 230/240 V at AC 50/60 Hz for 3 phase || 5 hp 460/480 V at AC 50/60 Hz for 3 phase || 7.5 hp 575/600 V at AC 50/60 Hz for 3 phase || 0.33 hp 115 V at AC 50/60 Hz for 1 phase
[Icw] Rated Short-Time Withstand Current105 A 40Β°C - 10 s power circuit || 210 A 40Β°C - 1 s power circuit || 30 A 40Β°C - 10 min power circuit || 61 A 40Β°C - 1 min power circuit || 100 A - 1 s signalling circuit || 120 A - 500 ms signalling circuit || 140 A - 100 ms signalling circuit
Rated Dutycontinuous IEC 60947-4-1
Trip Unit Technologythermal-magnetic
Coil Technologywithout built-in suppressor module
Flame RetardanceV1 conforming to UL 94
Signalling Circuit Frequency25...400 Hz
Motor Starter Typedirect on-line contactor
Power Range0-0.5 kW 100-120 V 3 phase || 0.55-1 kW 100-120 V 3 phase || 0-0.5 kW 200-240 V 3 phase || 0.55-1 kW 200-240 V 3 phase || 1.1-2 kW 200-240 V 3 phase || 0-0.5 kW 380-440 V 3 phase || 0.55-1 kW 380-440 V 3 phase || 1.1-2 kW 380-440 V 3 phase || 2.2-3 kW 380-440 V 3 phase || 4-6 kW 380-440 V 3 phase || 0-0.5 kW 480-500 V 3 phase || 0.55-1 kW 480-500 V 3 phase || 1.1-2 kW 480-500 V 3 phase || 2.2-3 kW 480-500 V 3 phase || 4-6 kW 480-500 V 3 phase || 0-0.5 kW 525-690 V 3 phase || 0.55-1 kW 525-690 V 3 phase || 1.1-2 kW 525-690 V 3 phase || 2.2-3 kW 525-690 V 3 phase || 4-6 kW 525-690 V 3 phase
Fire Resistance850Β°C IEC 60695-2-1
[Ics] Rated Service Short-Circuit Breaking Capacity100 % 690 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 400/415 V AC 50/60 Hz IEC 60947-2
Protective Coverwith
[Ui] Rated Insulation Voltagepower circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL, 690 V AC 50/60 Hz IEC 60947-2
Product CertificationsTSE || LROS (Lloyds register of shipping) || DNV || UL 508 type E || CSA || RINA || EZU || UL || ATEX || GL || CCC || BV || EAC, RINA || DNV || GOST || LROS (Lloyds register of shipping) || UL || GL || BV || CCC || CSA
Poles Description3P
Irms Rated Making Capacity250 A 440 V power circuit IEC 60947 || 140 A AC signalling circuit IEC 60947-5-1 || 250 A DC signalling circuit IEC 60947-5-1
Protective TreatmentTH
Network Frequency50/60 Hz IEC 60947-4-1
Operating Time12...22 ms closing || 4...19 ms opening
Fixing Mode35 mm symmetrical DIN rail clipped || panel screwed with 2 x M4 screws)
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947, 6 kV IEC 60947-2
[Uc] Control Circuit Voltage120 V AC 50/60 Hz
[Ue] Rated Operational Voltagepower circuit u003c= 690 V AC 25...400 Hz || power circuit u003c= 300 V DC, 690 V AC 50/60 Hz IEC 60947-2
Rated Breaking Capacity250 A 440 V power circuit IEC 60947
Operating Positionany position
Electrical Durability0.6 Mcycles 25 A AC-1 u003c= 440 V || 2 Mcycles 9 A AC-3 u003c= 440 V, 100000 cycles AC-3 440 V
Minimum Switching Current5 mA signalling circuit
[Ie] Rated Operational Current9 A 60Β°C) u003c= 440 V AC AC-3 power circuit || 25 A 60Β°C) u003c= 440 V AC AC-1 power circuit
Auxiliary Contact Composition1 NO + 1 NC
Climatic WithstandIACS E10
Minimum Switching Voltage17 V signalling circuit
Hold-In Power Consumption In Va7.5-7.5 VA 60 Hz 0.3 20Β°C) || 7-7 VA 50 Hz 0.3 20Β°C)
Maximum Operating Rate25 cyc/h, 3600 cyc/h 60Β°C
Suitability For Isolationyes IEC 60947-1
Product Or Component Typemotor starter
Control Circuit TypeAC 50/60 Hz
Non-Overlap Time1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Tightening Torque1.7 N.m screw clamp terminals, power circuit 1.7 N.m screw clamp terminals flat ? 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat ? 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2
Contact CompatibilityM2
Inrush Power In Va70-70 VA 60 Hz 0.75 20Β°C) || 70-70 VA 50 Hz 0.75 20Β°C)
Breaking Capacity100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ith] Conventional Free Air Thermal Current1 A IEC 60947-4-1, 25 A 60Β°C power circuit || 10 A 60Β°C signalling circuit
Heat Dissipation2-3 W 50/60 Hz
Ambient Air Temperature For Operation-20-60Β°C, -5-60Β°C
Auxiliary Contacts Typemechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Trip Unit Rating0.63-1 A
Average Impedance2.5 mOhm - Ith 25 A 50 Hz power circuit
Pollution Degree3
Ik Degree Of ProtectionIK04
Contactor Applicationresistive load || motor control
Connections - Terminalsscrew clamp terminals 2 1-6 mm? solid || screw clamp terminals 2 1.5-6 mm? flexible without cable end || screw clamp terminals 2 1-4 mm? flexible with cable end, power circuit screw clamp terminals 1 1-4 mm?flexible without cable end || power circuit screw clamp terminals 2 1-4 mm?flexible without cable end || power circuit screw clamp terminals 1 1-4 mm?flexible with cable end || power circuit screw clamp terminals 2 1-2.5 mm?flexible with cable end || power circuit screw clamp terminals 1 1-4 mm?solid without cable end || power circuit screw clamp terminals 2 1-4 mm?solid without cable end || control circuit screw clamp terminals 1 1-4 mm?flexible without cable end || control circuit screw clamp terminals 2 1-4 mm?flexible without cable end || control circuit screw clamp terminals 1 1-4 mm?flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm?flexible with cable end || control circuit screw clamp terminals 1 1-4 mm?solid without cable end || control circuit screw clamp terminals 2 1-4 mm?solid without cable end
Operating Altitude9842.52 ft (3000 m) without derating, 6561.68 ft (2000 m)
Ip Degree Of ProtectionIP20 IEC 60529, IP20 front face IEC 60529
Country of Origin (subject to change)China
Package Quantity1
TAGS:
#TESYS motor starter kit
#LC1D09G7 contac
#SCHNEIDER ELECTRIC
#Mfr GV2P05KD09G7
#Schneider Electric
#GRG4592199
#mfr:GV2P05KD09G7
#part number:GV2P05KD09G7
#pn:GV2P05KD09G7
#part code:GV2P05KD09G7
#item number:GV2P05KD09G7
#product code:GV2P05KD09G7
#manufacturer number:GV2P05KD09G7
#manufacturers part number:GV2P05KD09G7
#mfn:GV2P05KD09G7

Reviews

There are no reviews yet.

Add a review